Determination of D-Malate Using Immobilized D-Malate Dehydrogenase in a Flow System and its Application to Analyze the D-Malate Content of Beverages
スポンサーリンク
概要
- 論文の詳細を見る
The quantity of D-malate was determined using apparatus comprised of a reactor with immobilized D-malate dehydrogenase (D-MDH) in a flow line. NADH formed by an enzymatic reaction was fluorometrically detected. The optimal concentration of NAD^+ in the carrier was determined. The maximum peak areas due to NADH were observed at pH 8.0 when the pH of the carrier consisting of piperazine-1, 4-bis(2-ethanesulfonic acid) (PIPES) buffer ranged from 7.0 to 8.5. Various buffer types were also examined as carrier media at pH 8.0, and PIPES buffer showed the maximum peak area. When the carrier composed of PIPES buffer (0.1M, pH 8.0) containing 1mM NAD^+ and 5mM MgCl_2 was used, the calibration curve for D-malate was linear in the range of 0.02-50μM (r = 1.000). The detection limit (S/N = 3) was 0.01μM. Relative standard deviations of the peak area at 1μM and 10μM were 1.6% (n = 7) and 0.48% (n = 7), respectively. This method was applied to the analysis of D-malate in several beverages, and the recovery test of the added D-malate to samples was also carried out to afford good results.
- 公益社団法人日本薬学会の論文
- 2008-02-01
著者
関連論文
- Determination of Isocitrate Using Immobilized Isocitrate Dehydrogenase in a Flow System and its Application to Analyze the Total Isocitrate Content of Beverages
- Determination of the Inorganic Phosphorus Content in Serum by the Use of Immobilized Enzyme Reactions in an FIA System
- Determination of Glucose in Plasma Using Immobilized Enzymes in a Flow System
- Determination of L-Malate Using Immobilized Malate Dehydrogenase and Aspartate Aminotransferase in a Flow System and its Application to Analyze the L-Malate
- Simultaneous Determination of Ethanol and Acetaldehyde in Liquor Using a Flow System Composed of Two Enzyme Reactors and an Octadecylsilica Column
- Glucose Determination Using a Flow System with Enzyme Reactor and Application to Analysis of Glucose Content in Beverages
- Determination of D-Malate Using Immobilized D-Malate Dehydrogenase in a Flow System and its Application to Analyze the D-Malate Content of Beverages
- Determination of Acetaldehyde Using Immobilized Aldehyde Dehydrogenase in a Flow System and Application to Analysis of Acetaldehyde Content in Liquors
- Direct Determination of Nitrate Using Nitrate Reductase in a Flow System
- Determination of Formate Using Immobilized Formate Dehydrogenase in a Flow System and Its Application to Analyze the Formate Content of Foodstuffs
- Determination of Nitrate in Biological Fluids Using Nitrate Reductase in a Flow System
- Mechanism of the carboxylation of cyclohexanone with carbon dioxide catalyzed by 1,8-diazabicyclo[5.4.0]undec-7-ene.
- Fluorometric Determination of Amino Acids and Proteins Utilizing a Copper(II) Catalyzed Reaction.