Determination of Nitrate in Biological Fluids Using Nitrate Reductase in a Flow System
スポンサーリンク
概要
- 論文の詳細を見る
The concentration of nitrate in biological fluids was determined using nitrate reductase (NR) in a flow system. A merging zone method was applied, in which a zone of NR and that of nitrate in separate streams were merged, and allowed to react. The decrease in NADPH caused by the reaction between NR and nitrate was measured at 340 nm. The conditions were as follows: length of the reaction coil used for the enzymatic reaction was 250cm; 0.1M PIPES buffer (pH 7.5) was used as the first carrier (C_1); 0.1 M PIPES buffer (pH 7.5) containing 0.1 mM NADPH was used as the second carrier (C_2); the reaction coil was immersed in a water bath maintained at 32℃. Under these conditions, a linear calibration curve (r=0.994) was plotted for the concentration of nitrate between 1 and 100 μM with a detection limit (S/N=3) of 0.2 μM. The present method was applied to determine the amount of nitrate in serum, plasma and urine using samples that had not been deproteinized. The concentration of nitrate within each sample was calculated from differences observed in the peak areas obtained in the absence or presence of nitrate reductase. The recovery test of the nitrate added to biological fluids indicated the applicability of the present method to the determination of nitrate in them. The nitrate concentrations determined using this technique correspond well with those of other methods.
- 公益社団法人日本薬学会の論文
- 2001-02-01
著者
関連論文
- Determination of Isocitrate Using Immobilized Isocitrate Dehydrogenase in a Flow System and its Application to Analyze the Total Isocitrate Content of Beverages
- Determination of the Inorganic Phosphorus Content in Serum by the Use of Immobilized Enzyme Reactions in an FIA System
- Determination of Glucose in Plasma Using Immobilized Enzymes in a Flow System
- Determination of L-Malate Using Immobilized Malate Dehydrogenase and Aspartate Aminotransferase in a Flow System and its Application to Analyze the L-Malate
- Simultaneous Determination of Ethanol and Acetaldehyde in Liquor Using a Flow System Composed of Two Enzyme Reactors and an Octadecylsilica Column
- Glucose Determination Using a Flow System with Enzyme Reactor and Application to Analysis of Glucose Content in Beverages
- Determination of D-Malate Using Immobilized D-Malate Dehydrogenase in a Flow System and its Application to Analyze the D-Malate Content of Beverages
- Determination of Acetaldehyde Using Immobilized Aldehyde Dehydrogenase in a Flow System and Application to Analysis of Acetaldehyde Content in Liquors
- Direct Determination of Nitrate Using Nitrate Reductase in a Flow System
- Determination of Formate Using Immobilized Formate Dehydrogenase in a Flow System and Its Application to Analyze the Formate Content of Foodstuffs
- Determination of Nitrate in Biological Fluids Using Nitrate Reductase in a Flow System
- Mechanism of the carboxylation of cyclohexanone with carbon dioxide catalyzed by 1,8-diazabicyclo[5.4.0]undec-7-ene.
- Fluorometric Determination of Amino Acids and Proteins Utilizing a Copper(II) Catalyzed Reaction.