Simultaneous Determination of Ethanol and Acetaldehyde in Liquor Using a Flow System Composed of Two Enzyme Reactors and an Octadecylsilica Column
スポンサーリンク
概要
- 論文の詳細を見る
Simultaneous determination of ethanol and acetaldehyde was performed with an apparatus consisting of two enzyme reactors placed either side of an octadecylsilica column in a single flow line. The enzymes used were alcohol dehydrogenase for ethanol analysis, and aldehyde dehydrogenase for acetaldehyde analysis. The most favorable concentration of NAD^+ in the carrier for the simultaneous determination of ethanol and acetaldehyde was studied in wine or sake, in which the ethanol concentration was much higher that that of acetaldehyde. An NAD^+ concentration of 0.1 mM was adopted. To distinguish between NADH formed due to ethanol and that formed due to acetaldehyde, several buffers (pH 7.8) were also examined for use as the carrier medium, and triethanolamine buffer was found to be the most favorable. The calibration curve for acetaldehyde was linear (r^2=1.000) in the range of 0.2-100μM. With respect to ethanol, plotting the logarithm of the peak area versus that of the concentration gave a linear relationship (r^2=0.997) in the range of 0.04-100 mM. This method was applied to the simultaneous analysis of ethanol and acetaldehyde in several types of liquor. The results were similar to those obtained using a commercially available test-kit method, suggesting the reliability and practicality of this method in analyzing real samples.
- 公益社団法人日本薬学会の論文
- 2003-02-01
著者
-
Mori Hisakazu
Kyoritsu College of Pharmacy
-
Mori Hisakazu
慶応義塾大学 薬学部
-
Sekine Yumiko
Kyoritsu College of Pharmacy
-
Takahashi Yoshiko
Kyoritsu College of Pharmacy
関連論文
- Determination of Isocitrate Using Immobilized Isocitrate Dehydrogenase in a Flow System and its Application to Analyze the Total Isocitrate Content of Beverages
- Determination of the Inorganic Phosphorus Content in Serum by the Use of Immobilized Enzyme Reactions in an FIA System
- Determination of Glucose in Plasma Using Immobilized Enzymes in a Flow System
- Determination of L-Malate Using Immobilized Malate Dehydrogenase and Aspartate Aminotransferase in a Flow System and its Application to Analyze the L-Malate
- Simultaneous Determination of Ethanol and Acetaldehyde in Liquor Using a Flow System Composed of Two Enzyme Reactors and an Octadecylsilica Column
- Glucose Determination Using a Flow System with Enzyme Reactor and Application to Analysis of Glucose Content in Beverages
- Determination of D-Malate Using Immobilized D-Malate Dehydrogenase in a Flow System and its Application to Analyze the D-Malate Content of Beverages
- Determination of Acetaldehyde Using Immobilized Aldehyde Dehydrogenase in a Flow System and Application to Analysis of Acetaldehyde Content in Liquors
- Direct Determination of Nitrate Using Nitrate Reductase in a Flow System
- Determination of Formate Using Immobilized Formate Dehydrogenase in a Flow System and Its Application to Analyze the Formate Content of Foodstuffs
- Determination of Nitrate in Biological Fluids Using Nitrate Reductase in a Flow System
- Mechanism of the carboxylation of cyclohexanone with carbon dioxide catalyzed by 1,8-diazabicyclo[5.4.0]undec-7-ene.
- Fluorometric Determination of Amino Acids and Proteins Utilizing a Copper(II) Catalyzed Reaction.