Authors have developed a new analytical method for gaseous carbonyl compounds in indoor air using a passive sampler. The sampler consists of a porous polyethylene cylinder uniformly packed with O-(4-cyano-2-ethoxybenzyl)hydroxylamine (CNET) coated silica gel as a reactive adsorbent. After sampling, CNET derivatives were eluted by acetonitrile and subsequently determined by HPLC. Sampling rates for formaldehyde, acetaldehyde and acetone were determined by a small chamber experiment with a constant gas generation system and resulted in 74ml/min for formaldehyde, 44ml/min for acetaldehyde and 42ml/min for acetone. Effects of exposure time (8 and 24 hr), temperature (10, 25 and 40℃) and relative humidity (31-94%) on the rate were not apparent under the given conditions. The passive sampler was then applied for field measurements of carbonyl compounds in indoor air and gave similar results when compared to active samplings using 2,4-dinitrophenylhydrazine (DNPH) coated cartridges. The Ames test showed the CNET is preferable in safety handling because of its lower mutagenic activities than those of DNPH. Carbonyl compounds can be determined with reduced interference of ozone, because the CNET was less degradable when exposed to ozone compared with DNPH. Therefore, the CNET is a possible alternative to DNPH as trapping reagent in the passive sampling device for the determination of formaldehyde, acetaldehyde and acetone in indoor air.
- 2007-08-01
著者
-
Sekine Yoshika
Department Of Chemistry School Of Science Tokai University
-
SEKINE Yoshika
School of Earth and Environmental Sciences, Tokai University
-
Onishi Masayuki
Department Of Chemistry School Of Science Tokai University
-
Kitasaka Kazuya
Osaka Laboratory Sumika Chemical Analysis Service Ltd.
-
Sugihara Koichi
Osaka Laboratory Sumika Chemical Analysis Service Ltd.
-
Shimajiri Hatsumi
Osaka Laboratory, Sumika Chemical Analysis Service, Ltd.
-
Shimajiri Hatsumi
Osaka Laboratory Sumika Chemical Analysis Service Ltd.
関連論文
- 海洋性バクテリアVibrio fischeriの生物発光阻害に基づく大気中粒子状汚染物質のバイオモニタリング手法に関する研究(学生・若手研究者の論文)
- 活性化二酸化マンガンを用いたアンモニア選択的触媒還元法による低温脱硝
- 中国の大気中二酸化硫黄濃度の増減予測の検証
- DNPH捕集管-HPLC法を用いた家庭用冷蔵庫内のアルデヒド・ケトン類の測定
- 「考える」環境教育の実践 : 簡易測定法による大気中N0x濃度測定を通じて
- 教室室内空気質の管理方法に関する研究 : TVOCセンサーを用いた常時モニタリング
- ナノサイズ白金微粒子含有水溶液の物理化学性状および生体作用
- 高温域における塩化ナトリウムからの塩素ガスの発生に関する研究
- 国設大気測定綱(NASN)浮遊粒子状物質観測データにおける欠損値の補完
- 1D1018 海洋性バクテリアの生物発光阻害を利用した大気中粒子状汚染物質のバイオモニタリング(2手法-1計測分析,一般研究発表)