Comparison of 23 Gauge and 25 Gauge Anterior Capsulotomy Forceps
スポンサーリンク
概要
- 論文の詳細を見る
In cataract surgery, the most commonly-used procedure for incision of the anterior capsule is continuous curvilinear capsulorrhexis (CCC), developed by Gimbel and Neuhann [1]. As Gimbel has reported, CCC is a safe technique for phacoemulsification and aspiration (PEA) and intraocular lens (IOL) implantation [1-3]. The optimum incision method for CCC is thought to be that of using anterior capsulotomy forceps [4-8]. Recently, I have developed the side-port 23 gauge anterior capsulotomy forceps (23G forceps), manufactured by Asico, which can be manipulated via a small incision, as well as the side-port 25 gauge anterior capsulotomy forceps (25G forceps) and 25/23 gauge tapered anterior capsulotomy forceps (tapered forceps), manufactured by Inami, which are thought to provide even better ease of handling. In view of the fact that the visibility, ease of handling, bending, adverse effect on the wound, and effect on the cornea of these various forceps are important, the present comparison study among these forceps was conducted on pig lenses by means of 0.1% trypan blue staining [9] of the anterior capsule. It was found that capsulorrhexis was difficult with the 25G forceps because of the strong bend of the shaft. However, the tapered forceps has little bend, and like the 23G forceps, it showed outstanding handling and visibility and had little adverse effect on the wound.
- 東海大学の論文
著者
関連論文
- Suppression of Redox Activities of Rabbit Lens λ-Crystallin by Glutathionylation
- Effect of Diabetic Retinopathy on Redox State of Aqueous Humor and Serum Albumin in Patients with Senile Cataract
- λ-Crystallin Related to Dehydroascorbate Reductase in the Rabbit Lens
- The Effect of α_2-Agonist on IOP Rise Following Nd-YAG Laser Iridotomy
- P4-16 A Case of Clear Cell Hepatocellular Carcinoma
- The Microendoscope for Ciliary Process Photocoagulation in Neovascular Glaucoma
- A SIMPLIFIED METHOD FOR EVALUATION OF THIXOTROPY OF CONCRETE
- INFLUENCE OF SURFACE TEXTURE ON COLOR TRANSITION OF MORTAR
- SOILING OF CONCRETE SURFACES DUE TO MICROORGANISMS
- Rotational, Vibratiornal and Translational Temperatures for Regular and Sequence Band Transitions in Waveguide C0_2 Laser
- カンパチの類結節症進行における鰓の重要性
- The 23 Gauge Capsulorrhexis Forceps Having a Cystotome Function
- A case report of Intraocular Lens Luxation with the Capsular Bag after Vitrectomy
- Difference in Redox Status of Serum and Aqueous Humor in Senile Cataract Patients as Monitored via the Albumin Thiol-Redox State
- Effect of Foreign Gas on ν_3-Mode Vibrational Temperature for Regular and Sequence Band Transitions in Waveguide CO_2 Lasers
- Effect of Foreign Gas on Gain and Rotational and Translational Temperatures for Regular and Sequence Band Transitions in Waveguide CO_2 Laser
- A Method Using Sutures for Extraction of Subluxated Posterior Chamber Intraocular Lens and Transscleral Fixation : Spider Technique
- Comparison of 23 Gauge and 25 Gauge Anterior Capsulotomy Forceps
- Amino Acid Sequence and Western Blot Analyses of Ascorbate Free Radical Reductase Purified from Rabbit Lens Soluble Fraction