A Lumped Analog for the Dynamic Analysis of the Pressure-flow Relationships in the Human Brachial Artery
スポンサーリンク
概要
- 論文の詳細を見る
This paper dealt with the analysis of the dynamic pressure-flow relationships of the human brachial artery. One lumped analog circuit was proposed to represent this system, which was consisted from a series connected L and R_1 network terminated by a parallel connected C and R_2 network. Each of these network parameters were estimated from the actually recorded arterial pressure and flow waves at the root of this artery of 40 cases of human brachial arteries. The analog computation of the pulsatile arterial blood flow wave was carried out by giving the simultaneously recorded arterial pressure wave as an input. The results illustrated many undistinguishable resemblance between the actually recorded flow wave and the computed flow wave. The same procedure was tried to explain the flow disturbances in the patients caused by various reasons. The results of this analog simulation indicated the location and the nature of the flow disturbances along this arterial system for the purpose of the differential diagnosis.
- 東海大学の論文
著者
-
Okino Haruka
Department Of Physiology Tokai University
-
Okino Haruka
Department Of Physiology 2 School Of Medicine Tokai University
-
Okino Haruka
Department Of Physiology School Of Medicine Tokai University
関連論文
- A MECHANICAL MODEL OF AORTIC VALVULAR INSUFFICIENCY USING CANINE PAPILLARY MUSCLE : Cardiac Function (III) : III : 48 Annual Scientific Meeting, Japanese Circulation Society
- Effects of Fura-2 and Indo-1 on [Ca^]i in Spontaneously Beating Cultured Heart Cells
- The Link Between Free Radicals and Myocardial Injury : SYMPOSIUM ON PATHOPHYSIOLOGY IN THE EARLY STAGE OF ACUTE MYOCARDIAL INFARCTION AND ITS TREATMENT : 51th Annual Scientific Session of the Japanese Circulation Society
- -0779-QUANTIFICATION OF NONRADIOACTIVE MICROSHPERE BY FLUORESCENCE EXCIATION ANALYSIS TO MEASURE REGIONAL BLOOD FLOW
- Limitations in Calculating Left Ventricular Volume by Two Dimensional Geometry : An Exised Canine Heart Study
- Study on a New Index of Fetal Respiratory Function : a Novel Optical Analysis of the Amniotic Fluid by the Vacuum-dried Infrared Attenuated Total Reflection (ATR) Method
- A Lumped Analog for the Dynamic Analysis of the Pressure-flow Relationships in the Human Brachial Artery
- Chairmen's Introduction to the Panel Discussion : PANEL DISCUSSION ON TESTING METHODS FOR CARDIOVASCULAR DIAGNOSIS : Critiques on the Analytical Methods for Cardiac Events