パラコート感応性膜電極の作製と裁判化学への応用
スポンサーリンク
概要
- 論文の詳細を見る
A paraquat-sensitive electrode was constructed by use of a poly (vinyl chloride)-based membrane containing sodium tetrakis [3,5-bis (trifluoromethyl) phenyl] borate as an ion exchanger and 2-fluoro-2'-nitrodiphenyl ether as a membrane solvent. The minimum detection limit of paraquat was 5×10^<-7>M. The calibration slope of the electrode in linear region was 28 mV/decade. The selectivity coefficients against Na^+, K^+, Mg^<2+> and Ca^<2+> were less than 10^<-4>, and substantially, these inorganic ions did not interfere with the response to paraquat. This electrode was utilized for a criminal investigation. Paraquat added intentionally to drinks such as juice, cola and milk in cases of murder can speedily be measured by the paraquat-sensitive electrode without separating the herbicide from assay mixtures. By using the present electrode, we could estimate paraquat down to 5×10^<-5>M contained in juice. This sensitivity was sufficient enough for the detection of paraquat used in a crime : when the lethal dose of paraquat (2.4 g/a man of 60 kg) was mixed with juice (250 ml), the concentration became about 40 mM. The electrode was also applied to a clinical analysis, and paraquat in the serum could successfully be detected down to 2μM.
- 社団法人日本薬学会の論文
- 1992-04-30
著者
関連論文
- 携帯用コカイン電極の開発(医療と分析化学)
- パラコート感応性膜電極の作製と裁判化学への応用
- 53(P-25) Euryleneとその類縁体の不斉全合成 : イオン輸送能とその細胞毒性の関係(ポスター発表の部)
- イオン選択性電極
- 分子レセプタとしてカリックスアレーン誘導体を用いたセンサ開発
- 薬物作用解明のツールとしてのイオン電極
- イオン電極法による薬・毒物の定量
- イオン選択性電極と臨床化学分析
- 生理活性ペプチドと膜損傷 (生理活性物質の膜作用)
- Mode of Action of the Gramicidin S Analogs Lacking Hydrophilic Amino Acid Residues on Biomembranes
- IN SITU DETECTION OF HISTAMINE RELEASED FROM MAST CELLS BY USING A HISTAMINE-SENSITIVE MEMBRANE ELECTRODE
- INCREASED PERMEABILITY OF THE OUTER MEMBRANE OF Escherichia coli INDUCED BY THE DIMER IN COMPOUND 48/80
- Isolation of the Trimer of Compound 48/80 and Determination of Its Histamine-Releasing Activity
- Effect of Compound 48/80 on the Phase Transition Temperature and Permeability of Liposomal Membrane
- An Immunochemical Study with Potassium Ion-Loaded Liposomes
- ESR Studies on Bis (O, O'-diethyldithiophosphato) Oxovanadium [IV] in Ether Solutions
- イオノホアとしての有機スズ化合物
- 化学センサ2000 イオンセンサ
- 向精神薬フェンテルミンを認識するセンサー開発(3)
- トリエチルアンモニウム電極を用いた細胞内外pH差の測定
- 向精神薬フェンテルミンを認識するセンサー開発(第2報)
- 向精神薬フェンテルミンを認識するセンサー開発
- ヒスタミン電極の開発と肥満細胞からのヒスタミン遊離測定への応用 (Proceedings of the 29th Chemical Sensor Symposium,September 13〜14,1999〔和文〕)
- イオン電極法によるジアゼパムの定量
- アミン感応性膜電極を用いた特定アミノ酸の新しい検出方法
- Serum Br concentration measurements using bromine (Br) electrode in epileptic patients and these dynamic phase.