Cathodic Adsorptive Stripping Square-Wave Voltammetry of the Anti-inflammatory Drug Meloxicam
スポンサーリンク
概要
- 論文の詳細を見る
The adsorptive behavior of the anti-inflammatory drug meloxicam was studied by cyclic, differentia-pulse and square-wave voltammetry on a hanging mercury drop electrode(HMDE). The drug was accumulated at HMDE and a well-defined stripping peak current was obtained at -1.42V vs.Ag/AgCl(saturated KCl)electrode in acetate buffer solution(pH 5.0). A voltammetric procedure was developed for the determination of meloxicam using square-wave cathodic adsorptive stripping voltammetry(SW-CASV). The optimum working conditions for the determination of the drug were established. The analysis of meloxicam in human plasma was carried out satisfactorily.
- 公益社団法人日本薬学会の論文
- 2001-10-01
著者
-
Ghoneim Mohamed
Department Of Chemistry Faculty Of Science Tanta University
-
RADI Abd-Elgawad
Department of Chemistry, Faculty of Science, Mansoura University
-
BELTAGI Amr
Department of Chemistry, Faculty of Education, Tanta University
-
Radi Abd-elgawad
Department Of Chemistry Faculty Of Science (dumyat) Mansoura University
-
Radi Abd-elgawad
Department Of Chemistry Faculty Of Science Mansoura University
-
Beltagi Amr
Department Of Chemistry Faculty Of Education Tanta University
関連論文
- Cathodic Adsorptive Stripping Square-Wave Voltammetry of the Anti-inflammatory Drug Meloxicam
- Determination of Secnidazole in Urine by Adsorptive Stripping Voltammetry
- Electrochemical Study of the Antineoplastic Agent Etoposide at Carbon Paste Electrode and Its Determination in Spiked Human Serum by Differential Pulse Voltammetry
- Electrochemical Study of Zolpidem at Glassy Carbon Electrode and Its Determination in a Tablet Dosage Form by Differential Pulse Voltammetry