Influence of the Shape of Silver Contacts on the Spatial Distribution of Spectral Intensity of a Breaking Arc (Special Issue on Electromechanical Devices and Their Materials)
スポンサーリンク
概要
- 論文の詳細を見る
In a DC 50V/3.3 A circuit, the spatial distributions of the spectral intensities of breaking arcs near the cathode for silver contacts were measured on the contact surfaces of three different shapes: flat and spherical (1 mm radius and 2 mm radius) and the arc temperature and the metal-vapor quantity were calculated from the spectral intensities. The influence of the contact shape on the arc temperature and the metal-vapor quantity were also examined, as well as the arc tracks on the contact surfaces and the gain and loss of the contacts. Findings show the distributions of spectral intensities are non-symmetrical from the beginning to the extinction of the breaking arc for the flat contact: However, they are symmetrical in the latter half of the breaking in spite of the number of breaking arcs and the shape of contact surface for the spherical contact. The relationship between the area of the arc tracks on the cathode and the shape of contact surface is the same as the relationship between the existent areas of measured spectra and the shape of the contact surface. For the spherical contacts, the arc temperature and the metal-vapor quantity are affected a little by the radius of the curved of contact surface and the number of breaking arcs. However, the longer the arc duration, the higher the metal-vapor quantity is in the latter period of the breaking arc. For the flat contacts, the metal-vapor quantity is lower than those for the spherical contacts. The gain and loss of the contacts are less and the arc duration is shorter for the flat contact than for the spherical contact.
- 一般社団法人電子情報通信学会の論文
- 1999-01-25
著者
-
Kubono Takayoshi
Faculty Of Engineering Shizuoka Univ.
-
TAKEUCHI Mitsuru
Nagoya Municipal Industrial Research Institute
関連論文
- Dependence of Motion of Breaking Arc on Contact Separating Speed for Ag and Pd Contact Pairs in a DC42V Resistive Circuit(Arc Discharge & Related Phenomena,Recent Development of Electromechanical Devices (Selected Papers from ICEC2006))
- Optical Observation of Arc Discharges between Electrical Contacts Breaking at Low Speed in a DC42V Resistive Circuit (国際セッション IS-EMD2005) -- (Arc Discharges & Related Phenomena)
- Cathode and Anode Bright-Spot Behaviors of Breaking Arc between Electrical Contacts (国際セッション IS-EMD2005) -- (Arc Discharges & Related Phenomena)
- Erosion of Electrical Contact Surfaces in Breaking Arcs at Low Separating Speed (国際セッション IS-EMD2005) -- (Arc Discharges & Related Phenomena)
- Observations of the Eroded Surfaces and the Motion of Arc Spots at Each Breaking Operation of Silver Electrical Contacts(Arc Discharge & Related Phenomena, IS-EMD2004-Recent Development of Electro-Mechanical Devices)
- Cathode and Anode Bright-Spot Behaviors of Breaking Arc between Electrical Contacts with Low Separating Speed(Arc Discharge & Related Phenomena, IS-EMD2004-Recent Development of Electro-Mechanical Devices)
- Temperature Measurement of Breaking Arcs between Cu-Cu, Ni-Ni and Pd-Pd contact pairs in a DC 42V-10A(Session 8 : Automotive Application)
- Cathode and Anode Bright Spot Behaviors of Breaking Arc between Electrical Contacts with the Low Separating Speed(Session 2 : Arc Discharges & Related Phenomena)
- Comparison between the Surface Condition of Electrical Contacts and the Behavior of breaking Arcs Observed with a High-speed Camera(Session 2 : Arc Discharges & Related Phenomena)
- Temperature Measurements of Breaking Arc between Copper Contacts at Three Constant Speeds (10,20 and 30 mm/s)(Arc Discharge)(IS-EMD2003 : Recent Technical Trend of Electro-Mechanical Devices)
- Temperature Measurements and Behavior Observations of Breaking Arc between Copper Contacts (国際セッションIS--EMD 2003) -- (Session 4 Arc discharges and related phenomena)
- Temperature Measurements and Behavior Observations of Breaking Arc between Copper Contacts
- Time-Resolved Spectroscopic Temperature Measurement of Break Arcs in a D.C.42V Resistive Circuit
- Motion of Break Arcs Driven by External Magnetic Field in a DC42 V Resistive Circuit
- A Proposal on a New Algorithm for Volume Calculation Based on Laser Microscope Data(Contact Phenomena, IS-EMD2004-Recent Development of Electro-Mechanical Devices)
- Transferred Pip Formed on Ag Contacts Mounted on Relays in a DC42C Resistive Circuit
- Metal Transfer and Contact Bounce of Silver and Palladium Switching Contacts Mounted on Relays in a direct current Circuit (国際セッションIS-EMD2005) -- (Relays and Switches)
- The Relationship between Exchange of Applied Voltage Polarity and Growth of Transferred Pip on Ag/CdO Make-only Contacts in a DC42V-10A Circuit (国際セッション IS-EMD2005) -- (Automotive Application)
- Growth of Transferred Pip on AgNi10wt% Make-Only Contacts Mounted on Relays in a DC42V Circuit (国際セッション IS-EMD2005) -- (Automotive Application)
- Some Characteristics of AgPd40wt% Contacts in DC42V-6A or DC42V-4.2A Resistive Circuit (国際セッション IS-EMD2005) -- (Automotive Application)
- The Bi-directional Observation of Transferred Pips Formed on Ag/CdO12wt% Electric Contacts in DC42V-5A and 10A Resistive Circuit (国際セッション IS-EMD2005) -- (Automotive Application)
- Growth of Transferred Pip and Electrical Properties of AgCdO Make-Only Contacts in Resistive Circuit with DC 14 V and 42 V Power Supply(Automotive Application, IS-EMD2004-Recent Development of Electro-Mechanical Devices)
- Observation of Pips Formed on Ag/SnO_2 Contacts in DC14 V-21 A Resistive Circuit(Automotive Application, IS-EMD2004-Recent Development of Electro-Mechanical Devices)
- Growth of Transferred Pip and Electrical Property on AgCdO Make-only Contacts in a Resistive Circuit with dc 14V and 42V Power Supply(Session 8 : Automotive Application)
- Observation of Pips Formed on Ag/SnO_2 Contacts in DC14V-20A Resistive Circuit(Session 8 : Automotive Application)
- The moving characteristic of the breaking arc spots depending on the separating speed of Ag electrical contacts
- Relationship between Growth of Transferred Pip and Arc Duration at Electrical Contacts Mounted on Relays(Recent Development of Electro-Mechanical Devices (IS-EMD 2002))
- Relationships between growth of transferred pip and arc duration at electrical contacts mounted on relays (国際セッションIS-EMD2002〔英文〕)
- A Study Of The Pip Erosion Of Make-Only-Contacts Mounted on Relays
- Dependence of the Break arcs Driven by Transverse Magnetic Field on the Contact Opening Speed in a DC High-voltage Resistive Circuit
- Characteristics of Break Arcs Driven by Transverse Magnetic Field in a DC High-voltage Resistive Circuit
- Time-Resolved Spectroscopic Temperature Measurement of Break Arcs in a D.C.42 V Resistive Circuit
- Time-resolved Spectroscopic Temperature Measurement of Breaking Arcs in D.C.42V circuit
- Spectroscopic Temperature Measurement of Breaking Arcs Near Cathode and Anode Surfaces of Copper Contacts(Arc Discharge & Related Phenomena,Recent Development of Electromechanical Devices (Selected Papers from IS-EMD2005))
- Spectroscopic Temperature Measurement of Breaking Arcs near the Cathode and Anode Surfaces of Copper Contacts (国際セッション IS-EMD2005) -- (Arc Discharges & Related Phenomena)
- Effects of Contact Materials on Rotational Motion of Break Arcs Driven by Radial Magnetic Field
- Relationship between Arc Duration and Motion of Arc Spots for Break Arcs of Ag and Ag/ZnO Electrical Contacts
- An Experimental Equation of V-I Characteristics of Breaking Arc for Ag, Au, Cu and Ni Electrical Contacts(Recent Development of Electro-Mechanical Devices (IS-EMD 2002))
- Moving range and current density of breaking arc in DC 42 Volt resistive circuit
- Observation of Breaking Arcs of Ag or Cu Electrical Contact Pairs with a High-speed Camera (国際セッションIS--EMD 2003) -- (Session 4 Arc discharges and related phenomena)
- Rotational Motion of Break Arcs Driven by Radial Magnetic Field in a DC Resistive Circuit
- Motion of Break Arcs Driven by External Magnetic Field in a DC42 V Resistive Circuit
- Motion of Break Arcs Driven by External Magnetic Field in a DC42V Resistive Circuit(Session 3 -Arc Interruption-)
- Optical Observation of Arc Discharges between Electrical Contacts Breaking at Low Speed in DC42V Resistive Circuit(Arc Discharge & Related Phenomena,Recent Development of Electromechanical Devices (Selected Papers from IS-EMD2005))
- Experimental Equation of V-I Characteristics of Breaking Arc in the Air (国際セッションIS-EMD2002〔英文〕)
- Research on Calculation of Cathode Root Properties in Carbon Vacuum Arc (国際セッションIS--EMD 2003) -- (Session 4 Arc discharges and related phenomena)
- Research on Calculation of Cathode Root Properties in Carbon Vacuum Arc
- Influence of the Shape of Contact Surface on the Spatial Distribution of Spectral Intensity of Breaking Arcs in Palladium Contacts
- Temperature and Metal-Vapor Near Contacts in Pd Breaking Arcs by Spectroscopic Measurement
- A System of Measuring the Spatial Distribution of Spectroscopic Intensity in a Cross Section of Arc Column (Special Issue on Recent Electromechanical Devices)
- Characteristics of Break Arcs Driven by Transverse Magnetic Field in a DC High-Voltage Resistive Circuit
- Spectroscopic Determination of Temperature and Metal-Vapor for Copper Breaking Arc by Using a CCD Color Camera and an Additional Filter(Special Issue on Current Electromechanical Devices and Their Materials with Recent Innovations)
- An Experimental Equation for Dependence of Duration of Breaking Arcs on Supply Voltage with Constant Circuit Resistance(Arc Discharge & Related Phenomena, IS-EMD2004-Recent Development of Electro-Mechanical Devices)
- An Observation of the Breaking Arc between Silver Contacts Using a High Speed Color Video (Special Issue on Electromechanical Devices and Their Materials)
- Influence of the Shape of Silver Contacts on the Spatial Distribution of Spectral Intensity of a Breaking Arc (Special Issue on Electromechanical Devices and Their Materials)
- Experiment on the Radiated Magnetic Field Caused by a Breaking Arc (Special Issue on Discharge and Electromagnetic Interference)
- Effect of Shapes of Contact Surfaces on Break Arcs occurring between Electrical Contacts in which a Magnet is embedded
- Arc Duration and Rotational Frequency of Break Arcs Driven by Radial Magnet Field in a DC42 V Resistive Circuit
- Position and Shape of Break Arcs Driven by Transverse Magnetic Field
- Reignition of Break Arcs Magnetically Blown-out in a 450V DC Resistive Circuit