Evaluation of Coronary Stents In Vitro With CT Angiography : Effect of Stent Diameter, Convolution Kernel, and Vessel Orientation to the Z-Axis
スポンサーリンク
概要
- 論文の詳細を見る
Background The aims of the present study were to assess the effect of the stent diameter, convolution kernel, and vessel orientation to the z-axis on the evaluation of coronary stents, in vitro with computed tomography (CT) angiography. Methods and Results Seven vascular models (2 models without stenosis, 2 with obstruction, and 3 with stenosis) with an approximate inner diameter of 3 or 4mm, filled with contrast material (79 or 330HU) were scanned with a 16-detector CT. The diameter measurement of the stent lumen and stenosis evaluation were both done in an orientation parallel to the z-axis of the scanner using 4 convolution kernels. The measured diameters of the stented lumen were 47-57% and 36-45% smaller than the actual inner diameter of the 3- and 4-mm diameter models, respectively. The diameter measurement of the stent lumen and visualization of the in-stent stenosis were improved by using convolution kernels with higher spatial resolution. The in-stent artifacts were evaluated in 4 orientations (0°, 30°, 60°, 90°) to the z-axis. The artifact was the minimum in 0° to the z-axis, and the maximum in 90°. Conclusion Visualization of the lumen of a stent by CT is affected by its diameter, convolution kernel, and vessel orientation to the z-axis, and these factors should be taken into consideration in the stent evaluation.
- 社団法人日本循環器学会の論文
- 2005-08-20
著者
-
YOKOYAMA Naoyuki
Department of Cardiology, National Cardiovascular Center
-
古井 滋
帝京大学医学部附属病院中央放射線部
-
古井 滋
帝京大学医学部泌尿器科
-
古井 滋
帝京大学 医学部放射線科学教室
-
古井 滋
帝京大学放射線科
-
Isshiki Takaaki
Department of Cardiology, Teikyo University Hospital
-
神長 達郎
帝京大学医学部放射線科
-
鈴木 滋
帝京大学放射線科
-
神長 達郎
帝京大学放射線科
-
神長 達郎
帝京大学 医学部精神科学教室
-
神長 達郎
帝京大学医学部附属病院放射線科
-
Saitoh Masahiko
Ageo Central General Hospital
-
Suzuki Masatoshi
Ageo Central General Hospital
-
Suzuki Shigeru
Department of Radiology Teikyo University School of Medicine
-
Furui Shigeru
Department of Radiology Teikyo University School of Medicine
-
SUZUKI Masatoshi
Department of Veterinary Physiology, Veterinary Medical Science, The University of Tokyo
-
Isshiki Takaaki
The Department Of Medicine Teikyo University School Of Medicine
-
Isshiki Takaaki
Department Of Cardiology Teikyo University School Of Medicine
-
KAMINAGA Tatsuro
Department of Radiology, Teikyo University School of Medicine
-
Yamauchi Teiyu
Department of Radiology, Teikyo University School of Medicine
-
Kuwahara Sadatoshi
CT Clinical Science, Philips Medical Systems
-
Isshiki Takaaki
Department Of Internal Medicine Teikyo University
-
ISHIHARA TADAYUKI
National Higashisaitama Hospital
-
Yokoyama Naoyuki
Department Of Cardiology Teikyo University School Of Medicine
-
Kuwahara Sadatoshi
Ct Clinical Science Philips Medical Systems
-
Koganesawa Satoshi
Division Of Cardiology Teikyo University School Of Medicine
-
山内 禎祐
Department Of Radiology Teikyo University School Of Medicine
-
古井 滋
Department Of Radiology Teikyo University School Of Medicine
-
Yokoyama Naoyuki
Department Of Cardiology National Cadiovascular Center
-
Suzuki Masatoshi
Department Of Cardiology Teikyo University School Of Medicine
-
Isshiki Takaaki
Department Of Cardiology
-
Kaminaga Tatsuro
Department Of Radiology Teikyo University School Of Medicine
-
Kaminaga Tatsuro
Department Of Radiology Teikyo University Medical School
-
Yokoyama Naoyuki
Department Of Medicine Teikyo University School Of Medicine
-
Suzuki Shigeru
Department Of Cardiac Surgery The Jikei Univ. School Of Medicine. Aloka Co .ltd .
-
Suzuki Shigeru
Department Of Applied Physics Faculty Of Science Science University Of Tokyo
-
Isshiki Takaaki
Second Department Of Medicine Teikyo University School Medicine
-
Yamauchi Teiyu
Department Of Radiology Teikyo University School Of Medicine
-
FURUI Shigeru
Department of Radiology, Teikyo University School of Medicine
-
SUZUKI MASATOSHI
Department of Anatomy, Jikei University School of Medicine
-
Suzuki Shigeru
Department of Radiology, Teikyo University School of Medicine
関連論文
- Diagnostic Performance of a New Multifunctional Electrocardiograph During Uninterrupted Chest Compressions in Cardiac Arrest Patients
- 視覚的物体認識の二つの脳内機構(日本基礎心理学会第28回大会,大会発表要旨)
- Prevalence and Prognosis of Asymptomatic Coronary Artery Disease in Patients With Abdominal Aortic Aneurysm and Minor or No Perioperative Risks
- 虚血性心疾患における^Tc-PPN心筋製剤を用いた局所心筋潅流および左室局所壁運動の同時評価 : 安静時、運動負荷時の検討 : ポスター発表 : 第57回日本循環器学会学術集会
- IVRにおける患者の被ばく線量測定に関する基礎的検討(第31回秋季学術大会放射線防護管理関連演題発表後抄録)
- IVR実施4施設における術者の被ばく線量(第31回秋季学術大会放射線防護管理関連演題発表後抄録)
- IVR実施4施設における患者の被ばく線量(第31回秋季学術大会放射線防護管理関連演題発表後抄録)
- 肝細胞癌の動脈塞栓療法における患者と術者の被曝測定
- PJ-726 A Multicenter Registry of a Novel Filter Device for Distal Protection ; Filtrap ^Registry(Coronary revascularization, PCI-17, The 71st Annual Scientific Meeting of the Japanese Circulation Society)
- 経カテーテル血栓除去術 : 静脈血栓症への応用
- マルチスライスコンピューター断層撮影により評価した対角枝梗塞による心破裂の1例
- 生体認証を用いた医学生の出欠管理の試み
- 中枢神経症状をきたした突発性発疹の臨床像と画像の検討
- 膵頭十二指腸切除術後仮性総肝動脈瘤の1例
- 78 IVR実施4施設における術者の被曝線量(放射線管理 IVR被ばく)
- 77 IVR実施4施設における患者の被曝線量(放射線管理 IVR被ばく)
- 近位下行大動脈瘤に対するステントグラフト留置術の工夫 : 左鎖骨下動脈バイパス術の有用性
- ヘパリン起因性血小板減少症による下大静脈血栓・肺血栓梗塞症
- ^I-BMIPPによる糖尿病マウス心筋オートラジオグラフィの検討
- 35) 冠動脈造影が困難であった胸部大動脈疾患の術前冠動脈評価にマルチスライスCTが有用であった三例(第190回日本循環器学会関東甲信越地方会)
- 脳血管内手術における放射線インジケータを用いた被ばく線量推定法(第35回秋季学術大会放射線防護・管理関連後抄録)
- 48 脳血管内手術における放射線インジケータを用いた被ばく線量推定法(放射線管理IVR被ばく線量評価, 第35回日本放射線技術学会秋季学術大会プログラム)
- Kinky-hair 病のMR像
- PP-586 前立腺癌診断における Proton MR Spectroscopy (MRS) の有用性の検討(第95回日本泌尿器科学会総会)
- OP-286 MR spectroscopyを用いた限局性前立腺癌の局在診断(一般演題口演,第94回日本泌尿器科学会総会)
- Phenotypic Heterogeneity of Marfan-Like Connective Tissue Disorders Associated With Mutations in the Transforming Growth Factor-β Receptor Genes
- 耳垂ケロイドの術後照射
- OP-079 限局性前立腺癌に対するHIFUの効果判定にMRSは有用である(前立腺腫瘍/診断・マーカー4,一般演題口演,第96回日本泌尿器科学会総会)
- 視覚的短期記憶における視覚情報の時間的統合に関わる神経基盤の検討(脳機能計測と基礎心理学)
- 93) 新しい血栓吸引除去カテーテルにより初期治療に成功した急性下壁梗塞の一例
- 非対称図形の時間的統合に関わる神経基盤の検討(日本基礎心理学会第27回東北大会,大会発表要旨)
- 中耳真珠腫のCT-MRI合成画像作成の試み
- PP-1562 Quantitative Gated SPECTによる虚血性不全心の術後予後推測の試み
- PP1108 アシアロ糖蛋白受容体肝シンチの臨床的意義 : ICG負荷試験との比較検討
- PP727 MRI用肝臓造影剤(フェリデックス)による肝予備能評価の試み : GSA肝シンチ, ICG負荷試験との比較検討
- 4 Thrombus Aspiration Prior to Primary Coronary Intervention in Patients with ST Elevation Acute Myocardial Infarction. Results of the VAMPIRE Trial(New Horizon in Coronary Interventions for Acute Coronary Syndrome, The 71st Annual Scientific Meeting of t
- PJ-688 The Role of Heritable Connective Tissue Disorders in the Pathogenesis of Aortic Dissection at Young Onset(Peripheral circulation/Vascular disease-6, The 71st Annual Scientific Meeting of the Japanese Circulation Society)
- Coexistent True Aortic Aneurysm as a Cause of Acute Aortic Dissection
- Patients With Peripheral Artery Disease Who Complete 12-Week Supervised Exercise Training Program Show Reduced Cardiovascular Mortality and Morbidity(Vascular Medicine)
- 機能的MRI(fMRI)による脳機能の解析
- A Case of Acute Type B Aortic Dissection : Limited Role of Laboratory Testing for the Diagnosis of Mesenteric Ischemia
- 乳児期早期心室中隔欠損症修復術前後の心筋シンチグラフィ所見の検討
- 主肺動脈血流減少にシャントトラブルを合併した症例におけるMRIの有用性
- 川崎病に於ける梗塞心筋性状の経時的変化 : ^Tl心筋シンチグラフィの役割について
- 空間関係と大脳半球左右差2 : 視覚とイメージの脳内機構(発表要旨,日本動物心理学会第61回大会・日本基礎心理学会第20回大会合同大会)
- ^Tc-ECD SPECTによる脳腫瘍の評価 -^Tl SPECTとの比較-
- The Effectiveness of Aspiration before Angioplasty for Acute Myocardial Infarction-interim Results of Vacuum Aspiration Thrombus Removal (VAMPIRE) Study(Clinical Trials in Ischemic Heart Disease (IHD), The 69th Annual Scientific Meeting of the Japanese Ci
- PJ-639 Prevalence of Coronary Artery Disease in AAA Patients with Minor or No Perioperative Cardiovascular Risks According to the AHA/ACC Guideline(Cardiovascular surgery / CABG(02)(IHD),Poster Session(Japanese),The 72nd Annual Scientific Meeting of the J
- Sjogren-Larsson 症候群における^1H-MRS
- 脳回肥厚症の^1H-NMR spectroscopy
- ヘリカルCTをもちいたMinimum intensity projectionとCurved reformationによる主膵管描出
- ^Tc-HMPAO脳SPECTによる神経ベーチェット病の評価 -MR画像との比較-
- ヘリカルCTを用いた肝腫瘍,門脈,肝静脈の3次元表示
- 肝以外の動脈塞栓術 (特集 外科医必読 interventional radiology) -- (Vascular interventional radiology)
- IVRの歴史,現況,展望 (特集 外科医が知っておくべきIVRのすべて)
- 大静脈閉塞症 (特集 救急疾患におけるIVR)
- PJ-805 Prognostic Value of Combination of Coronary Artery Calcium and Carotid Artery Plaque Scores for Patients with Suspected Coronary Artery Disease(PJ135,CT/MRI (Coronary/Vascular) 2 (I),Poster Session (Japanese),The 73rd Annual Scientific Meeting of T
- PE-468 Angiographic and Clinical Outcomes of Severe Calcified Lesions Requiring Rotational Atherectomy in Hemodialysis(HD) and Non-hemodialysis Patients after SES Implantation(PE079,Coronary Revascularization, PCI (Complex Lesions) (IHD),Poster Session (E
- PE-149 Enhanced Platelet Activation in Patients with Hemodialysis after Coronary Stent Implantation(PE025,Thromboembolism/Antithrombotic Therapy/Thrombolysis 2 (IHD),Poster Session (English),The 73rd Annual Scientific Meeting of The Japanese Circulation S
- DPJ-060 Thrombectomy Improves Angiographic Outcome in ST-Segment Elevation Myocardial Infarction Cases without Visible Thrombus : Subanalysis from the VAMPIRE Trial(DPJ10,ACS/AMI (Clinical/Treatment) (IHD),Digital Poster Session (Japanese),The 73rd Annual
- OE-158 Significance of Pre-test Likelihood of Coronary Artery Disease in Patients with Coronary Artery Calcium Score Zero(OE27,CT/MRI (Coronary/Vascular) 1 (I),Oral Presentation (English),The 73rd Annual Scientific Meeting of The Japanese Circulation Soci
- PJ-927 Usefulness of Laser Doppler Flowmetry in Percutaneous Transluminal Angioplasty(Peripheral circulation / Vascular disease(10)(H),Poster Session(Japanese),The 72nd Annual Scientific Meeting of the Japanese Circulation Society)
- PJ-649 Comparison of Long-Term Clinical Outcomes of Single-Vessel Sirolimus-Eluting Stent Implantation in Hemodialysis Patients with Non-Hemodialysis Patients(Coronary revascularization, PCI(23)(IHD),Poster Session(Japanese),The 72nd Annual Scientific Mee
- PE-291 Incidence of Cardiac Death and Stent Thrombosis after Sirolimus-Eluting Stent Implantation in Hemodialysis Patients(Coronary revascularization,PCI(11)(IHD),Poster Session(English),The 72nd Annual Scientific Meeting of the Japanese Circulation Socie
- PE-233 Safety and Efficacy of Percutaneous Transluminal Angioplasty to Below-the-Knee Artery in Non-Critical Limb Ischemia(Peripheral circulation/Vascular disease(04)(H),Poster Session(English),The 72nd Annual Scientific Meeting of the Japanese Circulatio
- OJ-211 Significance of VlDAS D-dimer for Acute Coronary Syndrome Patients(Acute coronary syndrome, basic / clinical(02)(IHD),Oral Presentation (Japanese),The 72nd Annual Scientific Meeting of the Japanese Circulation Society)
- PE-462 Comparison of Clinical Outcomes of Percutaneous Transluminal Angioplasty to Superficial Femoral Artery with and without Stenting in Hemodialysis Patients(Peripheral circulation/Vascular disease-3, The 71st Annual Scientific Meeting of the Japanese
- 5 A Multicenter Registry of a Novel Filter Device for Distal Protection : Filtrap^ registry(New Horizon in Coronary Interventions for Acute Coronary Syndrome, The 71st Annual Scientific Meeting of the Japanese Circulation Society)
- Economic analysis of variance in the charge for percutaneous coronary interventional treatment
- 5 Impact of Acute Coronary Syndrome on the Late Stent Thrombosis after Drug Eluting Stent Implantation(Should Drug Eluting Stents be Indicated for the Patients with Acute Coronary Syndrome?,Controversy 3 (C-3) (IHD),The 73rd Annual Scientific Meeting of T
- CTワークステーション上の自動計測ソフトを用いた血管モデルの計測精度 : 画像再構成関数による計測精度の違い
- Accuracy and Efficiency of Left Ventricular Ejection Fraction Analysis, Using Multidetector Row Computed Tomography : Effect of Image Reconstruction Window Within Cardiac Phase, Slice Thickness, and Interval of Short-Axis Sections
- Coronary intervention in diabetic patients : Current perspective and the future
- 多発性出血性嚢胞を伴う子宮腺筋症の1例
- PJ-152 Glucose Intolerance and Chylomicron Remnants are Important Risk Factors of Coronary Heart Disease Especially with Metabolic Syndrome(Diabetes/Obesity/Metabolic syndrome-11 (H) PJ26,Poster Session (Japanese),The 70th Anniversary Annual Scientific Me
- Evaluation of Coronary Stents In Vitro With CT Angiography : Effect of Stent Diameter, Convolution Kernel, and Vessel Orientation to the Z-Axis
- Imaging of In-stent Stenosis Using 16-slice Computed Tomography : In Vitro Study with a Specially-made Phantom(X-ray/CT/MRI/DSA 2 (I), The 69th Annual Scientific Meeting of the Japanese Circulation Society)
- Assessment of Plaque Components in Chronic Total Occlusion by 16-slice Computed Tomography : Impact to the Crossability of CTO Lesion(Coronary Revascularization, PTCA/Stent/DCA/Rotablator/New Device 13 (IHD), The 69th Annual Scientific Meeting of the Japa
- PE-312 Three-dimensional Intravascular Ultrasonic Assessment of the Mechanism of Lumen Reduction of the Saphenous Vein Grafts after Coronary Artery Bypass Surgery(Cardiovascular Surgery/CABG 3 (IHD) : PE53)(Poster Session (English))
- PE-195 The Effect of Acoustic Output Power on Image Enhancement and Attenuation in Contrast Echocardiography(Echo/Doppler 9 (I) : PE33)(Poster Session (English))
- Early Detection of Doxorubicin-Induced Myocardial Damage by Ultrasound Tissue Characterization With Integrated Backscatter
- Modulation of oxidative burst of neutrophils by doxycycline in patients with acute myocardial infarction
- Increased leukocyte activity as a predictor for flow-limiting coronary lesions in patients with angina pectoris
- Factors Affecting the Patient's Skin Dose During Percutaneous Coronary Intervention for Chronic Total Occlusion
- Radiation Exposure to Patient's Skin During Percutaneous Coronary Intervention for Various Lesions, Including Chronic Total Occlusion
- Clinical Application of Radiosensitive Indicators Using Functional Dyestuff to the Measurement of Patient Skin Dose during Percutaneous Coronary Intervention (Coronary Revascularization, PTCA/Stent/DCA/Rotablator/New Device 8 (IHD), The 69th Annual Scient
- III.治療へのアプローチ 2.下大静脈フィルター
- PJ-207 Candesartan Treatment Switched from Ca-antagonist Resulted in the Regression of Cardiac Hypertrophy Independent to Ambulatory Blood Pressure Level.(Hypertension, Clinical 4 (H) : PJ35)(Poster Session (Japanese))
- Platelet Aggregability Under Shear is Enhanced in Patients With Unstable Angina Pectoris Who Developed Acute Myocardial Infarction
- IS082 Efficasy of Transradial Primary Stenting in Patiests with Acute Myocardial Infarction
- ^Ga シンチグラフィが放射線療法の治療効果判定に有用であった眼窩 MALT リンパ腫の1例
- Intrahepatic Cholangiocarcinoma Arising 34 Years After Excision of a Type IV-A Congenital Choledochal Cyst : Report of a Case
- PE-083 The Predictors of Incomplete Stent Expansion with Percutaneous Coronary Intervention in Hemodialysis Patients(Coronary revascularization, PCI-8 (IHD) PE14,Poster Session (English),The 70th Anniversary Annual Scientific Meeting of the Japanese Circu
- PE-111 Angiographical Characteristics with Plaque Contents Obtained in Thrombectomy for Acute Coronary Syndrome (ACS)(Acute coronary syndrome, basic/clinical-5 (IHD) PE19,Poster Session (English),The 70th Anniversary Annual Scientific Meeting of the Japan
- PE-086 Initial Clinical Experience with Distal Protection Using a Novel Self-expandable Filter-type Guide Wire in Patients Undergoing Percutaneous Coronary Intervention(Coronary revascularization, PCI-9 (IHD) PE15,Poster Session (English),The 70th Anniver
- OJ-192 Vein Graft Patency and Shortening in Aortocoronary Bypass Analyzed by Quantitative Coronary Analysis(Cardiovascular surgery/CABG-1 (IHD) OJ32,Oral Presentation (Japanese),The 70th Anniversary Annual Scientific Meeting of the Japanese Circulation So
- 2 Distal embolic protection in patients with acute coronary syndrome(Best Strategy for Acute Coronary Syndrome in Japan-The Proposals from the Clinical Forefront,Roundtable Discussion 6 (RT6) (IHD),The 70th Anniversary Annual Scientific Meeting of the Jap
- 1 Proliferation index as a cellular marker of metastatic potential and prognosis in colorectal carcinomas
- Health-Related Quality of Life of Japanese Patients With Chronic Heart Failure Assessment Using the Medical Outcome : Study Short Form 36
- CTワークステーション上の自動計測ソフトを用いた血管モデルの計測精度 : 画像再構成関数による計測精度の違い