Transluminal Percutaneous Septal Myocardial Ablation in a Patient With Hypertrophic Obstructive Cardiomyopathy
スポンサーリンク
概要
- 論文の詳細を見る
Reduction of septal mass by inducing septal infarction using catheter techniques is a new therapy for hypertrophic obstructive cardiomyopathy(HOCM). We report a case of severe HOCM that was dramatically improved by this non-surgical treatment. A 60-year-old woman with HOCM had suffered dyspnea(NYHA class III)with syncopal attack despite medical treatment. Left heart catheterization showed a resting pressure gradient across the left ventricular outflow tract of 156 mmHg. Two proximal septal branches of the anterior descending coronary artery were catheterized with a balloon catheter by the usual percutaneous coronary angioplasty techniques and were completely blocked by injection of absolute alcohol. The pressure gradient decreased to 26 mmHg after the procedure. Symptoms were markedly improved(NYHA class I)without any medical treatment. The reduced pressure gradient was maintained at the 3-month follow-up catheterization(36 mmHg). Further long-term follow-up is needed, but this treatment would seem to to be a promising technique for reducing pressure gradient in symptomatic patients with HOCM.
- 社団法人日本循環器学会の論文
- 1998-06-20
著者
-
SAKURAI Makoto
Department of Chemical Engineering, Tokyo University of Agriculture and Technology
-
Tsuchikane Etsuo
Toyohashi heart center
-
Kobayashi Tohru
Department Of Hematology And Oncology Nagoya University Graduate School Of Medicine
-
Izumi Masahiro
Department of Cardiology, Osaka Medical Center for Cancer and Cardiovascular Diseases
-
Tateyama Hitone
Shiga Medical Center For Adults
-
Tamai Hideo
Shiga Medical Center
-
Izumi Masahiro
Department Of Cardiology Osaka Medical Center For Cancer And Cardiovascular Diseases
-
Kitano Katsuya
First Department Of Internal Medicine Osaka Medical Center For Cancer And Cardiovascular Diseases
-
Yamazaki Keita
First Department Of Internal Medicine Osaka Medical Center For Cancer And Cardiovascular Diseases
-
Kobayashi Tohru
Department Of Cardiovascular Surgery Osaka Medical Center For Cancer And Cardiovascular Diseases
-
Otsuji Satoru
Department of Cardiology, Osaka Medical Center for Cancer and Cardiovascular Diseases
-
Tateyama Hitone
First Department of Medicine, Osaka Medical Center for Cancer and Cardiovascular Diseases, Departmen
-
Tsuchikane Etsuo
First Department of Medicine, Osaka Medical Center for Cancer and Cardiovascular Diseases, Departmen
-
Awata Nobuhisa
First Department of Medicine, Osaka Medical Center for Cancer and Cardiovascular Diseases, Departmen
-
Otsuji Satoru
Department Of Cardiology Osaka Medical Center For Cancer And Cardiovascular Diseases
-
Sakurai Makoto
Department Of Cardiovascular Surgery Osaka Medical Center For Cancer And Cardiovascular Diseases
-
Nakamura Toshinori
First Department of Internal Medicine, Osaka Medical Center for Cancer and Cardiovascular Diseases
-
Izumi Masahiro
First Department of Internal Medicine, Osaka Medical Center for Cancer and Cardiovascular Diseases
-
Otsuji Satoru
First Department of Internal Medicine, Osaka Medical Center for Cancer and Cardiovascular Diseases
-
Nakamura Toshinori
First Department Of Internal Medicine Osaka Medical Center For Cancer And Cardiovascular Diseases
-
Izumi Masahiro
Department Of Cardiology Osaka Medical Center For Cancer And Cardiovascular Diseses
-
Sakurai Makoto
Department Of Applied Chemistry College Of Engineering Chubu University
-
Kobayashi Tohru
Department Of Agricultural Chemistry Faculty Of Agriculture Kobe University
関連論文
- Novel Metal Monolithic Anodic Alumina Catalyst for Methane Catalytic Combustion, the External Heat Source for Methane Steam Reforming
- Thermal Performance of the Plate Fin Type Reactor with Anodized Alumina Catalyst for Methanol Decomposition
- PE-326 Feasibility and Efficacy of Paclitaxel-Eluting Stent in the Patients with Acute Coronary Syndrome : Optical Coherence Tomography Analysis(PE055,Intravascular Imagings (I),Poster Session (English),The 73rd Annual Scientific Meeting of The Japanese C
- PE-277 Comparison of Chronic Vascular Response following Coronary Stenting among Paclitaxel-Eluting, Sirolimus-Eluting and Bare-Metal Stent Using Optical Coherence Tomography(PE047,Coronary Revascularization, PCI (DES) 4 (IHD),Poster Session (English),The
- PE-075 Stent Fracture Detected by Multislice Computed Tomography after In-stent Restenosis Caused by "Full Metal Jacket" with Drugeluting Stents(PE013,CT/MRI (Coronary/Vascular) (I),Poster Session (English),The 73rd Annual Scientific Meeting of The Japane
- DPJ-047 Impact of Diabetes Mellitus and Plaque Characterization on Neointimal Proliferation after Sirolimus Eluting-Stent Implantation : Optical Coherence Tomographic Analysis(DPJ08,Intravascular Imagings (I),Digital Poster Session (Japanese),The 73rd Ann
- DPE-055 "Late Catch-up" in Restenosis following Sirolimus-Eluting Stent Implantation(DPE10,Angina Pectoris (Clinical) (IHD),Digital Poster Session (English),The 73rd Annual Scientific Meeting of The Japanese Circulation Society)
- OJ-015 Difference in Neointimal Growth on the Stent Struts Crossing a Side-branch Between Sirolimus-Eluting and Bare-Metal Stent : Optical Coherence Tomography Analysis(OJ03,Intravascular Imagings (I),Oral Presentation (Japanese),The 73rd Annual Scientifi
- PJ-821 Differences in Angiographic Characterization of In-Stent Restenosis After Sirolimus Eluting Stent Implantation From Original De Novo Coronary Stenosis(Coronary revascularization, PCI(26)(IHD),Poster Session(Japanese),The 72nd Annual Scientific Meet
- PJ-646 Impact of Drug-Eluting Stent for Treatment of Coronary Artery Disease in Dialysis Patients(Coronary revascularization, PCI(23)(IHD),Poster Session(Japanese),The 72nd Annual Scientific Meeting of the Japanese Circulation Society)
- PJ-378 Clinical outcomes of Sirolimus-eluting stent (SES) for AMI in this hospital : comparison with Bare metal stent (BMS)(Acute myocardial infarction, clinical(diagnosis/treatment)(10)(IHD),Poster Session(Japanese),The 72nd Annual Scientific Meeting of
- PJ-263 Predictors of Angiographical Restenosis and Major Adverse Cardiac Event after Sirolimus Eluting-Stent Implantation for Unprotected Left Main Coronary Artery Stenosis(Coronary revascularization, PCI(19)(IHD),Poster Session(Japanese),The 72nd Annual
- PJ-262 Long-term Outcomes Associated With Off-label Use of Sirolimuseluting Stents(Coronary revascularization, PCI(19)(IHD),Poster Session(Japanese),The 72nd Annual Scientific Meeting of the Japanese Circulation Society)
- PJ-143 Definition of Incomplete Stent Apposition by Optical Coherence Tomography(Intravascular endoscopy/Intravascular ultrasound(05)(I),Poster Session(Japanese),The 72nd Annual Scientific Meeting of the Japanese Circulation Society)
- PJ-062 Impact of Kissing Balloon After Single Stent Deployment for Bifurcation Lesions(Coronary revascularization, PCI(17)(IHD),Poster Session(Japanese),The 72nd Annual Scientific Meeting of the Japanese Circulation Society)
- PJ-057 Efficacy of Directional Coronary Atherectomy Prior to Sirolimus-Eluting Stent Implantation for Treatment of Unprotected Left Main Coronary Artery Bifurcation Stenosis(Coronary revascularization, PCI(16)(IHD),Poster Session(Japanese),The 72nd Annual
- OJ-001 The Efficacy of Drug-Eluting Stent for Patient with Chronic Total Occlusion(Coronary revascularization, PCI(05)(IHD),Oral Presentation(Japanese),The 72nd Annual Scientific Meeting of the Japanese Circulation Society)
- OE-252 Optical Coherence Tomographic Analysis of Neointimal Coverrage of Sirolimus-eluting Stent in Patients with Acute Coronary Syndrome(Coronary revascularization, PCI(02)(IHD),Oral Presentation(English),The 72nd Annual Scientific Meeting of the Japanes
- FRS-079 The efficacy of bilateral approach for the lesions with chronic total occlusion in acute results and follow up. : CART Resistry(Forefront Updates in PCI(02)(IHD),Featured Research Session,The 72nd Annual Scientific Meeting of the Japanese Circulat
- FRS-178 Debulking Of Chronic Total Occlusions With Rotational or Directional Atherectomy Before Stenting (DOCTORS) Trial : A Multicenter Randomized Study(Percutaneous Coronary Intervention (IHD) : FRS21)(Featured Research Session (English))
- FRS-079 The efficacy of bilateral approach for the lesions with chronic total occlusion in acute results and follow up. : CART Resistry(Forefront Updates in PCI(02)(IHD),Featured Research Session,The 72nd Annual Scientific Meeting of the Japanese Circulat
- OJ-005 The Long-Term Outcome for Patients with Chronic Total Occlusion Treated with Sirolimus-Eluting Stent : Japanese Multi-Center Registry(OJ01,Coronary Revascularization, PCI (DES) (IHD),Oral Presentation (Japanese),The 73rd Annual Scientific Meeting o
- PJ-102 Randomized Comparison of Aggressive Versus Less Aggressive Debulking with Directional Atherectomy before Stenting : A Serial 3-Dimentsional Intravascular Ultrasound Study(Coronary Revascularization, PTCA/Stent/DCA/Rotablator/New Device 4 (IHD) : PJ
- PE-126 Six-Year Clinical Outcome of directional coronary atherectomy (DCA) in treating left main trunk (LMT) lesions(Coronary Revascularization, PTCA/Stent/DCA/Rotablator/New Device 7 (IHD) : PE22)(Poster Session (English))
- PE-125 Efficacy of Continuous Hemodiafiltration during and after Percutanious Coronary Intervention in Patients with Mild Renal Dysfunction(Coronary Revascularization, PTCA/Stent/DCA/Rotablator/New Device 7 (IHD) : PE22)(Poster Session (English))
- OJ-367 Randomized Comparison of Aggressive Versus Less Aggressive Rotational Atherectomy Followed by Coronary Stenting for Severe Calcified Lesions(Coronary Revascularization, PTCA/Stent/DCA/Rotablator/New Device 10 (IHD) : OJ44)(Oral Presentation (Japane
- OJ-366 Effect of Preintervention Remodeling Type on Subsequent Coronary Artery Behavior after Directional Atherectomy(Coronary Revascularization, PTCA/Stent/DCA/Rotablator/New Device 10 (IHD) : OJ44)(Oral Presentation (Japanese))
- OE-352 Long-Term Follow-Up after Percutaneous Coronary Intervention of a Chronic Total Occlusion in Native Coronary Arteries(Coronary Revascularization, PTCA/Stent/DCA/Rotablator/New Device 13 (IHD) : OE44)(Oral Presentation (English))
- OE-347 Unprotected left main trunk angioplasty registry in Japan : Initial and long-term results(Coronary Revascularization, PTCA/Stent/DCA/Rotablator/New Device 13 (IHD) : OE44)(Oral Presentation (English))
- Percutaneous Transluminal Septal Myocardial Ablation for Hypertrophic Obstructive Cardiomyopathy : Initial and Follow-up Results in the First 27 Patients
- A Novel Drug Coating Stent Releasing Cilostazol for Inhibition of Neointimal Proliferation : Results of a Porcine Model of Coronary Restenosis
- Unprotected Left Main Trunk Angioplasty (the ULTRA experience) : Immediate and Mid-Term Results in Patients with AMI
- Acute Result of a New Directional Coronary Atherectomy Catheter Compared with Standard Device : Intravascular Ultrasound Findings
- Clinical Efficacy of Percutaneous Intervention for Chronic Total Occlusion of Native Coronary Arteries with Saphenous Vein Graft Failure
- Investigation of Anodic Alumina Supported Silver Catalyst for the Selective Reduction of NO by Propene: Promotional Effect of Hydrogen and Effect of Electrical Heating
- Propene-SCR of NO over Electrically Heating Anodic Alumina Supported Silver Catalyst
- PE-428 Comparison of Therapeutic Strategies for Coronary Artery Disease in Dialysis Patients between Bare Metal and Drug-eruting Stent Eras(PE072,Coronary Revascularization, PCI (DES) 7 (IHD),Poster Session (English),The 73rd Annual Scientific Meeting of
- OE-095 Comparison of Subsequent Vascular Response in Diabetic Patients Following Coronary Stenting Between Sirolimus- and Paclitaxel-Eluting Stents : Optical Coherence Tomography Analysis(OE16,Diabetes (H),Oral Presentation (English),The 73rd Annual Scien
- FRS-110 Difference in Neointimal Coverage on the Stent Strut between Sirolimus- and Paclitaxel-Eluting Stents : Optical Coherence Tomography Analysis(FRS23,Clinical Evidence of DES Era (1) (IHD),Featured Research Session (English),The 73rd Annual Scientif
- Promotional Effect of Titanium on the Catalytic Performance of Anodic Alumina Supported Silver Catalyst for the Selective Reduction of NO with Propene
- The Distribution of Fibrous Cap Thickness Measured by OCT in Patients with Acute and Stable Presentations of Coronary Artery Disease (Acute Coronary Syndrome, Basic/Clinical 7 (IHD), The 69th Annual Scientific Meeting of the Japanese Circulation Society)
- Impact of Optical Coherence Tomography on Visualizing Atherosclerotic Plaques in Patients with Acute Coronary Syndrome : Comparison with Intravascular Ultrasound(Intravascular Endoscopy/Intravascular Ultrasound 5 (I), The 69th Annual Scientific Meeting of
- Re-endotheliazation of Drug Eluting Stents vs. Bare Metal Stents after Two Months Observed with Optical Coherence Tomography(Coronary Revascularization, PTCA/Stent/DCA/Rotablator/New Device 10 (IHD), The 69th Annual Scientific Meeting of the Japanese Circ
- Correlation of Intravascular Ultrasound Based Tissue Characterization Software with in Vitro Histopathology in Human Coronary Atherosclerotic Plaques(Intravascular Endoscopy/Intravascular Ultrasound 4 (I), The 69th Annual Scientific Meeting of the Japanes
- Assessment of In-stent Restenosis with 64-slice Computed Tomography(X-ray/CT/MRI/DSA 3 (I), The 69th Annual Scientific Meeting of the Japanese Circulation Society)
- Visualization and Quantification of Coronary Stent by 64-slice Computed Tomography : A New Reliable Modality for Assessment of Implanted Stent(X-ray/CT/MRI/DSA 3 (I), The 69th Annual Scientific Meeting of the Japanese Circulation Society)
- Percutaneous Coronary Intervention for Complex Lesion Subsets in the Drug Eluting Stent Era(Recent Progress in Cardiovascular Surgery and Catheter Interventions, The 69th Annual Scientific Meeting of the Japanese Circulation Society)
- The One Year Result of Parallel Wire Technique under Going Percutaneous Coronary Intervention of Chronic Total Occlusions
- Acute and Follow-Up Outcomes of Percutaneous Transluminal Septal Myocardial Ablation for Patients with Hypertrophic Obstructive Cardiomyopathy
- Influence of Midventricular Obstruction on the Acute Results of Percutaneous Transluminal Septal Myocardial Ablation for Hypertrophic Obstructive Cardiomyopathy
- Beyond Five-Year Follow-Up after Stand-Alone Directional Coronary Atherectomy
- Late Regression of Target Lesions after Stand-Alone Directional Coronary Atherectomy
- The Effect of SO_2 and H_2O on the SCR-C_3H_6 of NO over a Transition Metals Supported Mesh-type Alumite Catalyst
- 陽極酸化アルミナ触媒を用いたディーゼル排ガスにおけるNOの選択還元
- Selective Catalytic Reduction of Nitric Oxide by Propene over a Cu-Mn-CeO_x/Al_2O_3/Al Alumite Catalyst
- Preparation of Alumite Support and Preliminary Activity Investigation for NO Removal in SCR-HC over Alumite Catalyst
- PJ-639 Ten-Years Clinical Outcome of Percutaneous Transluminal Septal Myocardial Ablation for Hypertrophic Obstractive Cardiomyopathy(PJ107,Cardiomyopathy/Hypertrophy (Basic, Clinical) (M),Poster Session (Japanese),The 73rd Annual Scientific Meeting of Th
- Performance Simulations of a Compact Plate Methane Steam Reformer Using an Electrically Heated Alumite Catalyst
- Angular Distribution of Ne Metastable Desorption Induced by Exciton Formation at the Surface of Solid Ne--Measurement and Computer Simulation (第35回真空に関する連合講演会プロシ-ディングス)
- Development of CO_2 Adsorbent on Anodic Alumite for Ethanol Steam Reforming
- Study on the Electro-Deposition of Platinum on Anodic Alumite Films for Catalytic Combustion of VOCs
- Sintering Effect of Platinum Catalysts on VOCs' Catalytic Combustion
- Two-Dimensional Coaxial Model for a Cylinder Methane Steam Reformer Using a Novel Plate Catalyst
- Preparation of Platinum Catalysts Supported on Anodized Aluminum for VOC Catalytic Combustion : The Effect of Sintering
- Catalytic Oxidation of Dichloromethane over Anodized Aluminum Film
- Preparation of Anodised Aluminium Catalysts by an Electrolysis Supporting Method for VOC Catalytic Combustion
- Preparation of Platinum Catalysts Supported on Anodized Aluminum for VOC Catalytic Combustion : The Effect of Supporting Method
- Study of Plate-Type Ru/Ceria-Al2O3 Catalysts for Kerosene Steam Reforming
- LEED Observation of Methane Monolayer Physisorbed on Ag(111) (第43回真空に関する連合講演会プロシーディングス--2002年10月16日〜18日,大阪)
- Study of Plate-Type Anodic Alumina Supported Ru Catalyst for Kerosene Steam Reforming under Electric Heating Pattern
- Synthesis of Anodic Alumina Nickel Catalysts and Deactivation Studies over Them for Methane Steam Reforming under Accelerated Degradation Testing
- Plate-Type Anodic Alumina Supported Ruthenium Catalysts for Steam Reforming of Kerosene: Influence of Calcination on Catalysts Reactivity
- Effect of Pore Widening Treatment on BET Surface Area of Rapidly Anodized Alumina Support
- A Plate-Type Anodic Alumina Supported Nickel Catalyst for Methane Steam Reforming
- Selective Catalytic Reduction of Nitric Oxide with Propene Using an Anodic Alumina Supported Silver Catalyst : NO_x Adsorption, TPD and TPSR Studies
- Development of a Methane Steam Reformer Using an Electrically Heated Alumite Catalyst: Start-Up Performance Investigated by the Numerical and Experimental Analysis
- Selective Catalytic Reduction of Nitric Oxide with Propene and Diesel Fuel as Reducing Agents over Anodic Alumina Catalyst
- Otolith Microstructure of the Embryo of the Viviparous Japanese Surfperch Ditrema temmincki(Embiotocidae)
- -0994-CONTINUOUS WAVE DOPPLER ASSESSMENT OF LEFT VENTRICULAR DIASTOLIC FILLING BEFORE AND AFTER PERCUTANEOUS MITRAL VALVULOPLASTY IN PATIENTS WITH MITRAL STENOSIS IN SINUS RHYTHM : THE 54th ANNUAL SCIENTIFIC MEETING OF THE JAPANESE CIRCULATION SOCIETY
- Reactivities of Stable Rotamers. XXXIX. Thermal Decomposition of t-Butyl 3-Methyl-3-(substituted 9-triptycyl)peroxybutanoate Rotamers^
- Coronary Artery Bypass Grafting for a Patient With Tangier Disease
- Mechanism of lumen loss after coronary intervention assessed by intravascular ultrasound : comparison of optimal lesion debulking and debulk-stenting
- Three-dimensional intravasucular ultraound analysis of in-stent neointimal proliferation comparing stenting after directional coronary atherectomy with primary stenting
- Plate Anodic Alumina-supported Nickel Catalysts in Steam Reforming of Methane : Effects of Hydrogen Addition, Electrical Heating, and Pt Doping
- Study of Plate-Type Ru/Ceria-Al_2O_3 Catalysts for Kerosene Steam Reforming
- Study of Plate-Type Anodic Alumina Supported Ru Catalyst for Kerosene Steam Reforming under Electric Heating Pattern
- Reactivity Improvement of Fe-Compounds for the UT-3 Thermochemical Hydrogen Procduction Process
- Non-Equilibrium Hydrogen Production from Ethanol Using CO_2 Absorption Ceramic and Precious Metal Catalysts
- Steam Reforming of Ethanol Using Silica-Coated Alumite Catalysts on Aluminum Plates (JIS A1050)
- Hydrogen Production from Ethanol Using a CO_2 Absorption Ceramic and Base Metal Catalysts
- Steam Reforming of Ethanol Using Silica-Coated Alumite Catalysts on Aluminum Plates (JIS A3003)
- Hydrogen Production from Ethanol Using a Plasma Reactor with an Alumite Catalyst Electrode
- Acute and long-term follow-up results of non-surgical septal myocardial ablation for hypertrophic obstructive cardiomyopathy
- Does optimal lesion debulking need stenting? : one year follow-up results of a prospective randomized trial
- Initial experiences in new atherectomy device Flexi-cut : efficacy on calcified lesions
- Preparation of Ammonium Polyphosphate Form II from the System of Ammonium Orthophosphate-Urea
- Transluminal Percutaneous Septal Myocardial Ablation in a Patient With Hypertrophic Obstructive Cardiomyopathy
- IDIOPATHIC VENTRICULAR FIRILLATION(IVF) : CLINICAL AND ELECTROPHYSIOLOSICAL ANALYSIS
- Effect of Ru and Pt Addition over Plate-type Catalysts for Methane Steam Reforming during Daily Start-up and Shut-down
- Hydrogen Production through Ethanol Steam Reforming on Conducting Heating Alumite Catalysts