EVALUATIONS OF CHARGE AMPLIFIER AND VIBRATION EXCITER FOR THE ESTABLISHMENT OF VIBRATION STANDARDS
スポンサーリンク
概要
- 論文の詳細を見る
Estimations of calibration uncertainty in vibration acceleration standards are described. The sensitivity of charge amplifiers and parasitic motions of a vibration exciter are measured, and then a method of analysis of uncertainty is proposed. In the calibration of charge amplifiers, the calibration procedure is explained in detail, and several CAs (charge amplifiers) are calibrated in terms of the frequency sensitivity gain, the long-term stability, the linearity for input charge, and the linearity for gain setting. The maximum discrepancy in the sensitivity gain is 4% among the tested CAs. A sensitivity difference of 1.5% still remains when same type CAs are compared. It should be mentioned that a difference of 1.5% is not negligible. Such a large difference is not well known up to the present time. As for the evaluation of the vibration exciter, its parasitic motion is investigated using a dual laser doppler vibrometer (LDV). The parasitic motion mainly consists of transverse, rocking and bending motions. In order to evaluate the transverse motion quantitatively, the ratio of the vibration amplitude in the transverse direction to that in the longitudinal direction is measured as a function of the frequency. The ratio curve shows clear peaks at the resonance frequencies of the exciter. A novel method of estimating the uncertainty due to the transverse motion is proposed. Additionally, the effects of rocking and bending motions on acceleration measurement are discussed. To reduce the effects, a simple compensation method is adopted, and improved calibration results are obtained.
- 一般社団法人日本機械学会の論文
著者
-
NAKANO Hidetoshi
National Research Laboratory of Metrology
-
Ohta Akihiro
National Metrology Institute Of Japan National Institute Of Advanced Industrial Science And Technolo
-
Usuda Takashi
National Inst. Of Advanced Industrial Sci. And Technol.
-
Usuda Takashi
National Metrology Institute Of Japan National Institute Of Advanced Industrial Science And Technolo
-
Ishigami Tamio
National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technol
-
Nakano Hidetoshi
National Metrology Institute Of Japan National Institute Of Advanced Industrial Science And Technolo
-
Ishigami Tamio
National Metrology Institute Of Japan National Institute Of Advanced Industrial Science And Technolo
関連論文
- Nanoscale verification of hardness indenters by atomic force microscopy
- Crack Measurements by Laser Ultrasonic at High Temperatures
- Photoacoustic Images by Rapid Scanning Method : Photoacoustic Spectroscopy and Ultrasonic Microscopy
- Precise Laser Ultrasonic Technique with Application to Silicon Velocity Measurements
- Calibration of acoustic emission sensors with laser-generated ultrasonic wave
- Measurement of Piezoelectric Constant of ZnO Thin Film on Si Microstructure
- Counting Error Elimination for Calibration of Vibration Pick-up Sensitivity in Fringe-counting Method
- Optical Detection of Transient Lamb Waves on Rough Surfaces by a Phase-Conjugate Method
- EVALUATIONS OF CHARGE AMPLIFIER AND VIBRATION EXCITER FOR THE ESTABLISHMENT OF VIBRATION STANDARDS
- Velocity Measurements of Laser-Generated Ultrasound at High Temperatures : Photoacoustic Spectroscopy
- An Electrostatically Driven Torsional Resonator with Two Degrees of Freedom (Part 1) -The Principle and Characteristics of Motion-