遠心圧縮機用ディフューザの内部流れのレーザ流速計による計測
スポンサーリンク
概要
- 論文の詳細を見る
Measurements of the velocity field in centrifugal compressor diffusers using a laser-two-focus velocimeter are presented. The exit flow distribution of high specific speed centrifugal compressor impellers is extremely distorted. The flow in vaneless diffusers is influenced by the distorted impeller exit flow. In vaneless diffuser, the flow distortion in the peripheral direction, such as rotating jet-wake region behind each impeller channel, was decreased smoothly. The flow distortion in the axial direction, however, was intensified and flow separation occurred near the shroud wall. On the other hand, no separation was observed in the diffuser with small height guide vanes on the shroud side wall. It was clearly shown that these guide vanes on the shroud side wall made the distorted flow uniform effectively.
- 社団法人日本機械学会の論文
- 1984-10-25
著者
-
星野 正和
日立 機械研
-
大木 博
(株)日立製作所 機械研究所
-
吉永 洋一
(株)日立製作所機械研究所
-
吉永 洋一
(株)日立製作所
-
星野 正和
(株)日立製作所機械研究所
-
星野 正和