糸状スペーサを巻いた電線で構成した変圧器巻線内の流動・伝熱特性に関する実験的研究 : 第2報,スペーサ直径の影響および液冷媒とガス冷媒の比較
スポンサーリンク
概要
- 論文の詳細を見る
In order to provide better cooling performance for transformer windings which use nonflammable coolant, conductors wound with thread spacers were applied to the windings to enlarge the cooling surface area. It was necessary to clarify the effects of the spacer diameter and different kinds of coolant on flow and cooling characteristics in the windings. Using two two-dimensional winding models, pressure drop in the windings and temperature rise of the conductors were measured for perfluorocarbon liquid and air. The two winding models consisted of model conductors in which thin heater pins and thermocouples were soldered together and wrapped in insulating paper. The conductors were also wound with two thread spacers having different diameters, 0.75mm and 0.5mm. The common frictional resistance and the heat transfer coefficient for perfluorocarbon liquid and air in vertical ducts between the conductors were derived for laminar and turbulent flow, respectively. The temperature rises for the thread spacer windings cooled by SF_6 gas were predicted as being signficantly lower than those in baffle plate windings for commercial transformers with the same pressure drop in the windings.
- 一般社団法人日本機械学会の論文
- 1994-07-25
著者
関連論文
- パーフルオロカーボン液を冷媒とした中容量変圧器巻線の基礎的冷却特性
- U形フロー方式による不燃変圧器巻線の基礎的冷却特性
- 糸状スペーサを巻いた電線で構成した変圧器巻線内の流動・伝熱特性に関する実験的研究 : 第2報,スペーサ直径の影響および液冷媒とガス冷媒の比較
- 糸状スペーサを巻いた電線で構成した変圧器巻線の流動・伝熱特性に関する実験的研究 : 第1報,折流板方式との比較
- パーフロロカーボン液を冷媒とした自冷式変圧器の自然循環流動特性と巻線冷却特性