パーフルオロカーボン液を冷媒とした中容量変圧器巻線の基礎的冷却特性
スポンサーリンク
概要
- 論文の詳細を見る
To develop a new type of mid-capacity transformer which uses perfluorocarbon liquid as the cooling and insulation medium, the basic flow and cooling characteristics in the windings were investigated. Three two-dimensional winding models having different horizontal and vertical duct spacings and number of coils in a section were used for the test. The models were composed of model conductors which had thermocouples and thin heater pins soldered and wrapped in insulating papers. The actual horizontal duct spacings, the horizontal and vertical temperature distributions of the windings and pressure drop were measured for each of the three models. The flow condition and winding configuration that cause overheating of the conductors were studied, and the influence of ripple or roughness of the insulating paper surface on pressure drop and heat transfer characteristics of the windings was investigated.
- 一般社団法人日本機械学会の論文
- 1992-07-25
著者
-
坂元 健
(株)日立製作所機械研究所
-
山崎 晴幸
日立ニュークリアエンジアリング(株)
-
山崎 晴幸
(株)日立製作所機械研究所
-
中武 良二
(株)日立製作所国分工場
-
上野 善人
(株)日立製作所国分工場
関連論文
- パーフルオロカーボン液を冷媒とした中容量変圧器巻線の基礎的冷却特性
- U形フロー方式による不燃変圧器巻線の基礎的冷却特性
- 糸状スペーサを巻いた電線で構成した変圧器巻線内の流動・伝熱特性に関する実験的研究 : 第2報,スペーサ直径の影響および液冷媒とガス冷媒の比較
- 糸状スペーサを巻いた電線で構成した変圧器巻線の流動・伝熱特性に関する実験的研究 : 第1報,折流板方式との比較
- パーフロロカーボン液を冷媒とした自冷式変圧器の自然循環流動特性と巻線冷却特性
- 不燃変圧器巻線の冷却特性 : 第1報, 強制循環式大容量変圧器の巻線冷却
- 油・フロン113混合液の水平管外核沸騰熱伝達の研究 : 第1報,沸騰熱伝達におよぼす油濃度の影響
- 油・フロン113混合液の沸騰熱伝達に及ぼすフロン濃度の影響
- 油とフロンの混合液体を用いた蒸発器の流動伝熱特性