Approximate Dynamic Analysis of Crossflow Heat Exchanger by the Method of Weighted Residuals
スポンサーリンク
概要
- 論文の詳細を見る
In this paper approximate lumped parameter models by the method of Weighted Residuals (MWR) are given for a cross flow heat exchanger and compared favourably with the Finite Difference Method (FDM). Two kinds of weighting function (Collocation Method). Several numerical examples show that the FDM model must be a considerablly higher order to secure the same accuracy as the MWR model does to simulate the static and dynamic characteristics.
- 一般社団法人日本機械学会の論文
著者
-
Terasaka Haruo
Institute For Atomic Energy Tokyo Shibaura Electric Works
-
Kanoh Hideaki
Faculty of Engineering, Osaka University
-
Masubuchi Masami
Faculty of Engineering, Osaka University
-
Kanoh Hideaki
Faculty Of Engineering Osaka University
-
Masubuchi Masami
Faculty Of Engineering Osaka University
関連論文
- Parameter Identification of Heat Exchangers by the Method of Stochastic Approximation
- Approximate Dynamic Analysis of Crossflow Heat Exchanger by the Method of Weighted Residuals
- Dynamic Characteristics of Rotary Regenerative Heat Exchanger by Galerkin's Method
- Control of Multi-Pass Heat Exchangers : Part 1,Dynamic Characteristics of Two-Pass Heat Exchangers
- Optimal Control System with Optimal Parameters
- Dynamic Analysis of a Plate Heat Exchanger System
- Discontinuous Optimal Control Problems