Optimization Technique for a Prompt Gamma-raySPECT Collimator System
スポンサーリンク
概要
- 論文の詳細を見る
Because background radiation in an irradiation room creates a problem with the PG-SPECT (Prompt Gamma-ray Single Photon Emission Computed Tomography) system, which evaluates the absorbed dose for the Boron Neutron Capture Therapy treatment, optimization of a collimator system was performed while taking the shielding of background gamma-rays into consideration. Assuming that a parallel-beam collimator is used, three parameters ・the diameter of a hole, the length of the collimator, and the number of detectors (the number of holes of the collimator) ・were selected for optimization. Because the combinations of these parameters are limitless, it is difficult to determine them simultaneously. Therefore, a statistically derived Optimization Criterion has been proposed to optimize these parameters. When the spatial resolution was 1 cm-FWHM (full width at half maximum), the optimal diameter of the collimator was 5. 4 mm, the optimal length was 321 mm, and the optimal number of detectors was 31 × 31.
- 日本放射線影響学会の論文
著者
-
Sakurai Yoshinori
広島大学原爆放射能医学研究所
-
Sakurai Yoshinori
Dep. Of Nucl. Eng. Kyoto Unrv.
-
Ishikawa Masayori
広島大学原爆放射線医科学研究所 分子発がん制御研究分野
-
Ishikawa Masayori
Department Of Medical Physics Hokkaido University Hospital
-
Ishikawa Masayori
Research Institute For Radiation Biology And Medicine Hiroshima University
-
KOBAYASHI TOORU
Kyoto University Research Reactor Institute
-
SAKURAI YOSHINORI
Kyoto University Research Reactor Institute
-
KANDA KEIJI
Kyoto University Research Reactor Institute
-
Kobayashi Toru
Kyoto University Research Reactor Institute
関連論文
- わが国のがんの現状と放射線治療 : 医学物理士育成が課題
- 追尾照射放射線治療のための腫瘍挙動予測シミュレーション(第17回MAGDAコンファレンス)
- 188 放射線治療への臨床応用を目的としたモンテカルロシミュレーションによるSOF検出器の応答特性(放射線治療 モンテカルロ,一般研究発表,日本放射線技術学会 第34回秋季学術大会)
- ホウ素含有壁によるマイクロドジメトリー (平成14年度専門研究会報告書「中性子捕捉療法システムの高度化」)
- 硼素含有壁を持つ組織等価比例計数管を用いた重水場の線質評価 (第37回京都大学原子炉実験所学術講演会)
- マイクロドジメトリ法によるHIMAC炭素治療ビームのRBEの推定
- SOF線量計による前立腺密封小線源治療時のリアルタイム線量測定
- 動体追跡照射治療装置用消滅γ線計測システムのシミュレーションによる検証
- 患者セットアップのための分子イメージング装置の開発 : Open-PET 装置の基礎シミュレーション
- S-1-4 Tumorigenicity by monoenergetic neutron in B6C3F1 mice(Present and Future of Researches on Biological Effects of Neutrons, Abstracts of the 46th Annual Meeting of the Japan Radiation Research Society)
- しきい値近傍^7Li(p, n)^7Be反応直接中性子を用いた術中照射BNCTの実現性の検討
- Optimization Technique for a Prompt Gamma-raySPECT Collimator System
- A simulation study on absorhed dose distribution in a living body for gadolinium neutron capture therapy.
- Cellular effect of thermal neutron capture treatment using ^B_1-para-boronophenylalanine: Lethal effect on melanoma cells with different degrees of X-ray sensitivity
- 中性子捕捉療法のための熱中性子リアルタイムモニタの開発
- SOF検出器によるBNCT治療中のリアルタイム熱中性子束評価 (平成14年度専門研究会報告書「中性子捕捉療法システムの高度化」)
- ホウ素中性子捕捉療法における光ファイバーを用いた熱中性子束モニターの開発 (第37回京都大学原子炉実験所学術講演会)
- ^B(n, αγ)^7Li反応即発γ線計数における解析的誤差低減法
- Directional Distribution of Radiation around an Accident at a Uranium Fuel Factory in Tokai-mura, 1999
- Microdosimetric Evaluation of Secondary Particles in a Phantom Produced by Carbon 290 MeV/nucleon Ions at HIMAC
- 非侵襲的ホウ素濃度分布測定システムの基礎的検討
- 診断X線領域における極微小光ファイバ線量計の基礎特性評価(第66回総会学術大会放射線防護・管理関連演題発表後抄録)
- Measurement of Residual ^Eu Activity Induced by Atomic BombNeutrons in Nagasaki and the Contribution of Environmental Neutrons to This Activity
- Calculation of Neutron-induced Activity Based on Updated Leakage Spectrum from Little Boy
- A Crack Model of the Hiroshima Atomic Bomb: Explanation of the Contradiction of "Dosimetry System 1986"
- 本当は一年かかる原発処理--間違いだらけの放射能報道 (総力特集 東日本大震災 日本人の再出発)
- リスク・コミュニケーション : 豊かなリスク概念と豊かな対話の場の生成へ向けて
- 浜松ホトニクス(株)豊岡製作所/中央研究所
- Tumor induction by monoenergetic neutrons in B6C3F1 mice
- Measurements of Activation Cross Sections on Spallation Reactions for ^Co and ^Cu at Incident Neutron Energies of 40 to 120 MeV
- A Method to Estimate the Fast-Neutron Fluence for the Hiroshima Atomic Bomb
- Energy-dependent RBE of Neutrons to Induce Micronuclei in Root-tip Cells of Allium cepa Onion Irradiated as Dry Dormant Seeds and Seedlings
- Relative Biological Effectiveness of Fission Neutrons for Producing Micronuclei in the Root-tip Cells of Onion Seedlings after Irradiation as Dry Seeds
- Neural Networks for the Neutron Spectrum Determination Based on the Foil Activation Method
- Chemical Separation for 63Ni Measurement
- Measurement of residual radioactivity ^Co and ^Ni for the evaluation of atomic-bomb neutron (II)
- Measurement of residual radioactivity ^Co and ^Ni for the evaluation of atomic - bomb neutrons
- The comparison of dose distributions in a water phantom for accelerator-based and reactor-based neutron irradiation fields for NCT.
- A Consideration about Neutron Irradiation Systems for Boron Neutron Capture Therapy using Accelerators and Research Reactors
- Biological Effect of Intermediate Energy Neutrons on BNCT
- 9H-06 腫瘍の体内変動を考慮した放射線治療における照射法の検討(OS-13(3) 光を利用した医療診断デバイス)
- 5-224 北海道大学大学院工学院における医学物理士・放射線治療品質管理士コース((02)専門科目の講義・演習-III,口頭発表論文)