Band Intensities of the 2.7 μm and 4.8 μm CO_2 Bands
スポンサーリンク
概要
- 論文の詳細を見る
The CO. absorption measurements have been carried out using an infrared spec-trometer at pressures up to 50 atm in the 2.7 and 4.8 qm regions. By using the Wilson-Wells-Penner-Weber method, the values of band intensity have been found to be73.1 f 1.8 cm 'aim ' at STP and 0.174:0.008 cm 'atm ' at STP for the 2.7 and4.8 qm bands respectively. The calculated spectral absorptances by line-by-line pro-cedures were also compared with the experimental results to check the validity of ourband intensiy values.