Cross-Correlation by Single-bit Signal Processing for Ultrasonic Distance Measurement
スポンサーリンク
概要
- 論文の詳細を見る
Ultrasonic distance measurement using the pulse-echo method is based on the determination of the time of flight of ultrasonic waves. The pulse-compression technique, in which the cross-correlation function of a detected ultrasonic wave and a transmitted ultrasonic wave is obtained, is the conventional method used for improving the resolution of distance measurement. However, the calculation of a cross-correlation operation requires high-cost digital signal processing. This paper presents a new method of sensor signal processing within the pulse-compression technique using a delta-sigma modulated single-bit digital signal. The proposed sensor signal processing method consists of a cross-correlation operation employing single-bit signal processing and a smoothing operation involving a moving average filter. The proposed method reduces the calculation cost of the digital signal processing of the pulse-compression technique.
- (社)電子情報通信学会の論文
- 2008-04-01
著者
-
Kurosawa Minoru
Department Of Information Processing Tokyo Institute Of Technology
-
Katagiri Takashi
Sutekina Inc.
-
HIRATA Shinnosuke
Department of Information Processing, Tokyo Institute of Technology
-
Hirata Shinnosuke
Department Of Information Processing Interdisciplinary Graduate School Of Science And Engineering To
-
Kurosawa Minoru
Department Of Advanced Applied Electronics Tokyo Institute Of Technology
関連論文
- Two-Dimensionally Self-Holding Deflection Mirror Using Surface Acoustic Wave Motor
- Single Process to Deposit Lead Zirconate Titanate (PZT) Thin Film by a Hydrothermal Method
- Cross-Correlation by Single-bit Signal Processing for Ultrasonic Distance Measurement
- Growth of Epitaxial {100}-Oriented KNbO3--NaNbO3 Solid Solution Films on (100)\text{cSrRuO3$\varparallel$(100)SrTiO3 by Hydrothermal Method and Their Characterization
- Estimation of Cavitation Sensor with Hydrothermally Synthesized Lead Zirconate Titanate Film on Titanium Cylindrical Pipe: Spatial Distribution of Acoustic Cavitation Field and Basic Characteristics of Cavitation Sensor
- Ultrasonic distance and velocity measurement by low-calculation-cost Doppler-shift compensation and high-resolution Doppler velocity estimation with wide measurement range
- Design of a Cylindrical Ultrasonic Micromotor to Obtain Mechanical Output
- Cylindrical Micro Ultrasonic Motor Utilizing Bulk Lead Zirconate Titanate (PZT)
- Accuracy and resolution of ultrasonic distance measurement with high-time-resolution cross-correlation function obtained by single-bit signal processing
- Growth of Epitaxial KNbO3 Thick Films by Hydrothermal Method and Their Characterization
- Fundamental Study on One-Dimensional-Array Medical Ultrasound Probe with Piezoelectric Polycrystalline Film by Hydrothermal Method: Experimental Fabrication of One-Dimensional-Array Ultrasound Probe
- High-Accuracy Measurement of Small Movement of an Object behind Cloth Using Airborne Ultrasound
- Doppler Velocity Estimation Based on Spectral Characteristics of M-Sequence-Modulated Signals in Ultrasonic Measurement for Moving Objects
- Three-dimensional position and velocity measurements using a pair of linear-period-modulated ultrasonic waves