変圧器の過熱異常部位判定方法の精度向上
スポンサーリンク
概要
- 論文の詳細を見る
The maintenance control of oil-immersed transformer based on dissolved gas analysis of insulation oil is carried out according to the Electric Technology Research Association report “The maintenance control of oil-immersed transformer". According to this diagnostic method, it is possible to discriminate between discharge mode and overheating mode. But in the overheating mode, it is difficult to judge the abnormality of an iron core group and the one of a winding group exactly. As for the cause of the gas occurrence of the overheat mode, the wrong point of the iron core occupies most. However, it has the difficulty of the countermeasure in the maintenance spot. Because it had to cope with it urgently when there was a wrong point in the winding group.So, we did the experiment of the gas occurrence using actual models of winding and iron core, and could know the characteristics of the gas occurrence. The estimated precision improvement of the overheating point inside the transformer could be attempted, by adding the way of diagnosing which these characteristics were used for to the Electric Technology Research Association method.
- 2005-12-01
著者
-
小林 隆幸
東京電力(株)
-
塚尾 茂之
東京電力(株)
-
小川 吉晴
(株)日本AEパワーシステムズ
-
福原 博
(株)明電舎
-
小林 隆幸
東京電力
-
小林 隆幸
東京電力(株)工務部
-
塚尾 茂之
東京電力
関連論文
- 変圧器の過熱異常部位判定方法の精度向上
- 500kV遮断器の直流分限界遮断性能検証について
- 系統事故時の直流性リアクトル放電電流の遮断器電流遮断現象
- 500kV送電線の電荷減衰時定数
- 電力機器電気絶縁へのナノコンポジット適用に関する一考察
- 経年大形変圧器の流動帯電保守診断技術の高度化--蓄積電荷密度測定装置と絶縁物経年劣化補正手法の導入
- 経年変圧器における流動帯電現象
- 絶縁合理化と1100kV用避雷器
- 油入経年変圧器における流動帯電増大現象
- 新信濃変電所1号周波数変換装置老朽化に伴うリプレース
- 経年変圧器の流動帯電増大現象
- アルカリ・シリカ反応による磁器碍管の吸湿劣化診断技術
- 電力・エネルギー部門大会座長のコメントと回答 : 45 変圧器I
- 日本における66-500kV用酸化亜鉛形避雷器の適用状況について
- 解説 直流送電用避雷器の開発と実用化
- 直流用避雷器の技術動向
- 大容量交流系統における責務
- GIS絶縁スペーサの直流残留電荷に対する耐圧性能評価試験法の提案
- GIS中エポキシ絶縁物の直流残留電荷に対する耐圧性能の評価
- ブッシング[改訂](JEC-5202-2007)
- GIS中エポキシ絶縁物の直流抵抗と帯電特性について
- 電力・エネルギー部門大会座長のコメントと回答 : 11 監視・計測I
- 500kV系送電の実適用に係わる技術史について
- 電力用油浸紙コンデンサの経年劣化について
- 電力用油浸紙コンデンサの劣化特性
- 電力エネルギー供給網における環境対策 : 送変電分野における取り組み
- Zinc Oxide Surge Arresters and HVDC 125kV-upgrade 500kV Converter Stations : Power Technology of Japan through the Experience of Developments and Applications of Gapless Metal Oxide Surge Arresters
- Zinc Oxide Surge Arresters and HVDC125kV-upgrade 500kV Converter Stations : Power Technology of Japan through the Experience of Developments and Applications of Gapless Metal Oxide Surge Arresters
- Verifications on the Installed Number of Surge Arresters for 66-500kV Power Systems in Japan
- 米国ニューヨーク駐在記
- 500kV三相一括形大容量変圧器の開発
- 変電所設備の最適運用のための技術動向--設備の能力限界までの活用,長期活用技術 (特集 変電技術の最近の動向)
- 澁澤賞受賞テーマ(3)変圧器の過熱異常部位判定手法確立による経年変圧器の信頼性向上および運用性向上
- Insulation Co-ordination based on 1100kV High Performance Surge Arresters
- 変電所の雷対策
- FRAによる実運用変圧器の異常診断事例
- 第43回CIGREパリ大会報告 : 開会式, パネルセッション, 研究委員会
- AHPの一対比較を用いた変電所設備健全度の可視化
- 経年変圧器の長期保全ビジョン構築に向けた取組み (特集 電力用変圧器の保守技術と将来ビジョン)
- 1100kV Substation - Basic Design/Specifications of GIS for UHV AC and its Verification Test and Site
- 「電力・エネルギー分野を支える変電技術の新展開」特集号によせて