Potential Behavior of Biochemically Modified Gold Electrode for Extended-Gate Field-Effect Transistor
スポンサーリンク
概要
- 論文の詳細を見る
We propose potentiometric detection of biomolecules using an extended-gate field-effect transistor (EGFET). Using a gold film electrode as the extended gate, the stability of the interface potential was characterized for a shift and a drift, and found to depend on the surface roughness of the gold electrode. The surface of the gold film was coated with self-assembled monolayers (SAMs) of various types of alkanethiol molecules with functional sites such as amino groups, carboxyl groups, hydroxyl groups and oligonucleotides. In all the alkanethiol molecules, the interface potential decreased drastically just after the introduction of each molecule because of the negative charges of thiol groups in aqueous solutions. Moreover, the complementary target deoxyribonucleic acid (DNA) has been introduced to the gold electrode modified with oligonucleotide probes and hybridized with them. The interface potential shifted in the negative direction due to the negative charges of the target DNA. Thus, the charge density change due to DNA hybridization as well as the adsorption of alkanethiol molecules on the gold electrode could be successfully detected using the biochemically modified EGFET.
- Published by the Japan Society of Applied Physics through the Institute of Pure and Applied Physicsの論文
- 2005-04-15
著者
-
Matsumoto Shinya
Ryokusei M.e.s Co. Ltd.
-
Miyahara Yuji
Center For Nanobio Integration The Univ. Of Tokyo
-
Miyahara Yuji
Biomaterials Center National Institute For Materials Science
-
Sakata Toshiya
Dep. Of Materials Engineering Graduate School Of Engineering The Univ. Of Tokyo
-
Sakata Toshiya
Biomaterials Center National Institute For Materials Science
-
Nakajima Yoshio
Ryokusei M.e.s Co. Ltd.
関連論文
- Capacitance-voltage measurement of transporting function at cell membrane (特集 インテリジェントバイオチップ)
- Potential Behavior of Biochemically Modified Gold Electrode for Extended-Gate Field-Effect Transistor
- Potential Behavior of Bio-Chemically Modified Electrode for Extended Gate Field Effect Transistor
- Cell Adhesion Characteristics of Chemically Modified Silicon Nitride Surfaces
- Quasi-Static Capacitance-Voltage Measurement for DNA Hybridization Using Integrated Field Effect Devices
- Potentiometric Detection of Single Nucleotide Polymorphism Using Genetic Field Effect Transistor
- DNA Analysis Chip Based on Field-Effect Transistors
- Detection of Molecular Charges at Cell Membrane