Simultaneous Determination of D-Glucose and 3-Hydroxybutyrate by Chemiluminescence Detection with Immobilized Enzymes in a Flow Injection System
スポンサーリンク
概要
著者
-
橘 正樹
山梨大学大学院医学工学総合研究部物質・生命工学専攻
-
木羽 信敏
山梨大学大学院医学工学総合研究部物質・生命工学専攻
-
Koizumi H
Department Of Applied Chemistry And Biotechnology Interdisciplinary Graduate School Of Medicine And
-
KIBA Nobutoshi
Department of Applied Chemistry, Faculty of Engineering, University of Yamanashi
-
TACHIBANA Masaki
Department of Applied Chemistry, Faculty of Engineering, University of Yamanashi
-
TANI Kazue
Department of Applied Chemistry, Faculty of Engineering, University of Yamanashi
-
KOIZUMI Hitoshi
Department of Applied Chemistry, Faculty of Engineering, University of Yamanashi
-
INOUE Youhei
Department of Applied Chemistry and Biotechnology, Interdisciplinary Graduate School of Medicine and
-
Tani Kazue
Department Of Applied Chemistry And Biotechnology Interdisciplinary Graduate School Of Medicine And
-
Tani Kazue
Department Of Applied Chemistry And Biotechnology Faculty Of Engineering Yamanashi University
-
Inoue Youhei
Department Of Applied Chemistry And Biotechnology Interdisciplinary Graduate School Of Medicine And
-
Kiba Nobutoshi
Department Of Applied Chemistry And Biotechnology Faculty Of Engineering Yamanashi University
-
Koizumi H
Division Of Materials Chemistry Graduate School Of Engineering Hokkaido University
-
Koizumi Hitoshi
Department Of Applied Chemistry And Biotechnology Faculty Of Engineering Yamanashi University
-
Tachibana Masaki
Department Of Applied Chemistry And Biotechnology Faculty Of Engineering Yamanashi University
関連論文
- 固定化ヒスタミンオキシダーゼを用いる吸光検出フローインジェクション分析による魚醤中のヒスタミンの定量(安心と安全に役立つ分析化学)
- 熱加水分解/フローインジェクション分析吸光検出法によるセメント中の臭素の定量方法の開発
- セメント中のフッ素の定量のための加湿を必要としない新しい熱分解前処理法の開発
- セメント中のフッ化物イオンの吸光検出/フローインジェクション分析のための簡便・迅速な熱加水分解前処理
- 化学発光検出/高速液体クロマトグラフィーによるマルトオリゴ糖の高感度定量
- 311 化学発光法による魚肉中のヒスタミン計測
- Flow-Injection Determination of L-Histidine with an Immobilized Histidine Oxidase from Brevibacillus borstelensis KAIT-B-022 and Chemiluminescence Detection
- Simultaneous Determination of Choline and Acetylcholine Based on a Trienzyme Chemiluminometric Biosensor in a Single Line Flow Injection System
- Simultaneous Determination of D-Glucose and 3-Hydroxybutyrate by Chemiluminescence Detection with Immobilized Enzymes in a Flow Injection System
- Flow-through Micro Sensor Using Immobilized Peroxidase with Chemiluminometric FIA System for Determining Hydrogen Peroxide
- Flow-through Chemiluminescence Sensor Using Immobilized Histamine Oxidase from Arthrobacter crystallopoietes KAIT-B-007 and Peroxidase for Selective Determination of Histamine
- Flow-through Chemiluminescence Sensor Using Immobilized Oxidases for the Selective Determination of L-Glutamate in a Flow-Injection System
- Chemiluminometric Determination of Uric Acid in Plasma by Closed-loop FIA with a Coimmobilized Enzyme Flow Cell
- Simultaneous Determination of _L-Phenylalanine and Branched-chain _L-Amino Acids in Plasma by Liquid Chromatographic System with a Coimmobilized Enzyme Reactor and Fluorescence Detection
- Comparison of Three Chromatographic Systems for Determination of Organic Acids in Wine
- Post-column enzyme reactors for chemiluminometric detection of glucose, 1,5-anhydroglucitol and 3-hydroxybutyrate in an anion-exchange chromatographic system
- Differences of Fluorine in Cements Determined by Photometric Methods after Distillation and Pyrolysis
- 化学発光検出フロースルーセンサー
- Role of the Sympathetic Nervous System in Gastric Functional Changes Induced by Thyrotropin-Releasing Hormone in Rats
- Flow-Injection Method for the Simultaneous Determination of D-Glucose and 3-Hydroxybutyrate with Co-Immobilized Enzyme Reactors and a Chemiluminometer
- Color Stability of an Indirect Composite Polymerized with Two Different Laboratory Polymerization Systems
- Influence of Laboratory Procedure on Attractive Force of Magnetic Attachment Systems
- Effect of Varying Polymerization Modes on Flexural Strength of an Indirect Composite Reinforced with a Monomer-Impregnated Glass Fiber Material
- Effect of Noble Metal Conditioner on Wear Resistance of Composite-to-metal Bonded Specimens
- Toothbrush Abrasion Resistance of an Indirect Prosthodontic Composite
- Successful Ablation of Left-Sided Accessory Pathways in a Patient with Coronary Sinus Atresia Using 3-Dimensional Mapping System