Two-Dimensional Tracking of Heart Wall for Detailed Analysis of Heart Function at High Temporal and Spatial Resolutions
スポンサーリンク
概要
- 論文の詳細を見る
For noninvasive and quantitative measurements of global two-dimensional (2D) heart wall motion, speckle tracking methods have been developed and applied. These methods overcome the limitation of tissue Doppler imaging (TDI), which is susceptible to aliasing, by directly tracking backscattered echoes by pattern matching techniques, i.e., the cross-correlation or the sum of absolute differences, in real time. In these conventional methods, the frame rate (FR) is limited to about 200 Hz, corresponding to the sampling period of 5 ms. However, myocardial function during the isovolumic contraction period obtained by these conventional speckle tracking methods remains unclear owing to low temporal and spatial resolutions of these methods. Moreover, the accuracy of the speckle tracking method depends on an important parameter, i.e., the size of the correlation kernel. To track backscattered echoes accurately, it is necessary to determine the optimal kernel size. However, the optimal kernel size has not been thoroughly investigated. In this study, correlation kernel size, which determines the tracking accurately, was optimized by evaluating root mean squared (RMS) errors in the lateral and axial displacements of a phantom estimated by speckle tracking methods at high spatial and temporal resolutions. For this purpose, the RF data from the longitudinal-axis cross-sectional view for the interventricular septum (IVS) were acquired on the basis of parallel beam forming (PBF) to improve temporal and spatial resolutions. A wide transmit beam scanned in 7 different directions sparsely and 16 receiving beams were generated for each transmission. The RF data of the phantom and the heart wall were obtained at high spatial (angle intervals of scan lines: 0.375 degrees) and temporal [frame rate (FR): 1020 Hz] resolutions. The determined optimal size of the correlation kernel was $7.9{\degree} \times 4.8\,\text{mm}$. Estimated displacements of the phantom were in good agreement with the actual displacement at an RMS error of 0.34 mm. Furthermore, the IVS motion during the isovolumic contraction (IC) was analyzed in detail. The speckle tracking method using the optimal kernel size $7.9{\degree} \times 4.8\,\text{mm}$ was applied to multiple points in IVS to estimate 2D displacements during the IC period. In this period, a rapid displacement of IVS at a small amplitude of 1.5 mm, which suggests the expansion of the left ventricle and has not been measured by conventional tracking methods at a low temporal resolution, was detected by 2D tracking. Furthermore, the displacement on the apical side was found to be delayed by 10 ms compared with that on the basal side. These results indicate the potential of this method in the high-accuracy estimation of 2D displacements and detailed analyses of physiological function of the myocardium.
- 2010-07-25
著者
-
Kanai Hiroshi
Graduate School Of Biomedical Engineering Tohoku University
-
Hasegawa Hideyuki
Graduate School Of Biomedical Engineering Tohoku University
-
Honjo Yasunori
Graduate School of Biomedical Engineering, Tohoku University, Sendai 980-8579, Japan
関連論文
- Relationship between upper limb peripheral artery stiffness using the radial artery and atherosclerotic parameters
- Tissue structure of arterial wall revealed with elasticity imaging
- Cross-Sectional Elasticity Imaging of Arterial Wall by Comparing Measured Change in Thickness with Model Waveform
- Measurement and analysis of vibration in the myocardium telescopic motion for novel echo-graphic diagnosis
- Tissue Characterization of Atherosclerotic Plaque by Ultrasonic Measurement of Regional Elasticity
- Ultrasonic Measurement of Regional Elasticity of Arterial Wall for Evaluation of Vulnerability of Atherosclerotic Plaque
- Two-Dimensional Tracking of Heart Wall for Detailed Analysis of Heart Function at High Temporal and Spatial Resolutions
- Ultrasonic Imaging of Propagation of Contraction and Relaxation in the Heart Walls at High Temporal Resolution
- Reduction of Influence of Decrease in Signal-to-Noise Ratio in Measurement of Change in Thickness of Arterial Wall Due to Heartbeat
- Accuracy Evaluation in the Measurement of a Small Change in the Thickness of Arterial Walls and the Measurement of Elasticity of the Human Carotid Artery
- Automated Identification of the Heart Wall Throughout the Entire Cardiac Cycle Using Optimal Cardiac Phase for Extracted Features
- Noninvasive Measurement of Transient Change in Viscoelasticity Due to Flow-Mediated Dilation Using Automated Detection of Arterial Wall Boundaries
- Multi Element Diverging Beam from a Linear Array Transducer for Transverse Cross Sectional Imaging of Carotid Artery: Simulations and Phantom Vessel Validation
- Measurement of Angular Dependence of Ultrasonic Scattering from Wire Phantom Mimicking Myocardial Fiber
- In Vivo Measurement of Small Velocity Signals and Change in Thickness of the Heart Walls
- Ultrasonic Measurement of Transient Change in Stress–Strain Property of Radial Arterial Wall Caused by Endothelium-Dependent Vasodilation
- Modified Phased Tracking Method for Measurement of Change in Thickness of Arterial Wall
- High-frame-rate echocardiography using diverging transmit beams and parallel receive beamforming
- Improvement in Accuracy of Ultrasonic Measurement of Transient Change in Viscoelasticity of Radial Arterial Wall Due to Flow-Mediated Dilation by Adaptive Low-Pass Filtering (Special Issue : Ultrasonic Electronics)
- Evaluation of Rate of Change in Thickness of Heart Wall by Measuring Time Variation of Ultrasonic Integrated Backscatter during a Cardiac Cycle (Special Issue : Ultrasonic Electronics)
- Frequency Analysis of Strain of Cylindrical Shell for Assessment of Viscosity
- Construction of Reference Data for Tissue Characterization of Arterial Wall Based on Elasticity Images
- Optimization of Correlation Kernel Size for Accurate Estimation of Myocardial Contraction and Relaxation
- Tissue Classification of Arterial Wall Based on Elasticity Image
- Measurement of displacement and strain in biological tissue generated by ultrasonic dual acoustic radiation force
- Basic Study on Detection of Outer Boundary of Arterial Wall Using Its Longitudinal Motion
- Change in Elasticity Caused by Flow-Mediated Dilation Measured Only for Intima–Media Region of Brachial Artery
- Measurement of Angular Dependence of Ultrasonic Echo for Estimation of Surface Roughness
- Cross-Sectional Elastic Imaging of Arterial Wall Using Intravascular Ultrasonography
- Modeling of Ultrasonic Echo from Posterior Arterial Wall for Accurate in-vivo Detection of Intima-Media Complex Boundaries
- Cross-Sectional Elasticity Imaging of Carotid Arterial Wall in Short-Axis Plane by Transcutaneous Ultrasound
- Generation of Strain Inside Objects Using Dual Acoustic Radiation Force
- Threshold Setting for Likelihood Function for Elasticity-Based Tissue Classification of Arterial Walls by Evaluating Variance in Measurement of Radial Strain
- Measurement of Elastic Moduli of the Arterial Wall at Multiple Frequencies by Remote Actuation for Assessment of Viscoelasticity
- Measurement of Change in Wall Thickness of Cylindrical Shell Due to Cyclic Remote Actuation for Assessment of Viscoelasticity of Arterial Wall
- Estimation of Scatterer Diameter Using Ultrasonic Backscattering Property for Assessment of Red Blood Cell Aggregation
- Designing Beam Steering for Accurate Measurement of Intima-Media Thickness at Carotid Sinus
- Detection of Arterial Wall Boundaries Using an Echo Model Composed of Multiple Ultrasonic Pulses (Special Issue : Ultrasonic Electronics) -- (Biomedical ultrasound)
- Accurate Ultrasonic Measurement of Surface Profile Using Phase Shift of Echo and Inverse Filtering
- Improvement of Automated Identification of the Heart Wall in Echocardiography by Suppressing Clutter Component
- Investigation of Frequency Characteristics in Cutting of Soft Tissue Using Prototype Ultrasonic Knives
- Automated Detection of Intima-Media Complex Boundaries in Longitudinal Section of Carotid Artery by Fitting Echo Model Composed of Multiple Ultrasonic Pulses to Measured Signal
- Ultrasonic Measurement of Minute Displacement of Object Cyclically Actuated by Acoustic Radiation Force
- Increasing Bandwidth of Ultrasound Radio Frequency Echoes Using Wiener Filter for Improvement of Accuracy in Measurement of Intima--Media Thickness
- Flow-Mediated Change in Viscoelastic Property of Radial Arterial Wall Measured by 22 MHz Ultrasound
- Ultrasonic Measurement of Change in Elasticity due to Endothelium Dependent Relaxation Response by Accurate Detection of Artery-Wall Boundary
- Modeling of Ultrasonic Echo from Posterior Arterial Wall for Accurate in-vivo Detection of Intima-Media Complex Boundaries