Experimental Study of High-Range-Resolution Medical Acoustic Imaging for Multiple Target Detection by Frequency Domain Interferometry
スポンサーリンク
概要
- 論文の詳細を見る
We employed frequency domain interferometry (FDI) for use as a medical acoustic imager to detect multiple targets with high range resolution. The phase of each frequency component of an echo varies with the frequency, and target intervals can be estimated from the phase variance. This processing technique is generally used in radar imaging. When the interference within a range gate is coherent, the cross correlation between the desired signal and the coherent interference signal is nonzero. The Capon method works under the guiding principle that output power minimization cancels the desired signal with a coherent interference signal. Therefore, we utilize frequency averaging to suppress the correlation of the coherent interference. The results of computational simulations using a pseudoecho signal show that the Capon method with adaptive frequency averaging (AFA) provides a higher range resolution than a conventional method. These techniques were experimentally investigated and we confirmed the effectiveness of the proposed method of processing by FDI.
- Published by the Japan Society of Applied Physics through the Institute of Pure and Applied Physicsの論文
- 2009-07-25
著者
-
Sakamoto Takuya
Graduate School Of Infomatics Kyoto University
-
TAKI Hirofumi
Graduate School of Infomatics, Kyoto University
-
SATO Toru
Graduate School of Infomatics, Kyoto University
-
Kimura Tomoki
Graduate School Of Infomatics Kyoto University
-
Sakamoto Takuya
Graduate School of Informatics, Kyoto University, Yoshida-honmachi, Sakyo-ku, Kyoto 606-8501, Japan
-
Kimura Tomoki
Graduate School of Informatics, Kyoto University, Yoshida-honmachi, Sakyo-ku, Kyoto 606-8501, Japan
-
Taki Hirofumi
Graduate School of Informatics, Kyoto University, Yoshida-honmachi, Sakyo-ku, Kyoto 606-8501, Japan
関連論文
- High-resolution UWB Doppler radar interferometric imaging algorithm for multiple moving targets with smoothed pseudo Wigner distribution(Radar Technology,ICSANE 2010 (International Conference on Space, Aeronautical and Navigational Electronics))
- Evaluation of Edge Electron Temperature Fluctuations Using a Conditional Technique on TST-2
- Effect of Metallothionein on Doxorubicin-induced Hepatotoxicity(PROCEEDINGS OF 24TH SYMPOSIUM ON TOXICOLOGY AND ENVIRONMENTAL HEALTH)
- 22C-10-4 Lipopolysaccharide-Induced Lethality in D-Galactosamine-Sensitized Metallothionein-Null Mice.
- Experimental Study of Robust and High-Resolution Ultrasound Imaging Algorithm with Adaptive Smoothing Techniques(WSANE 2008 (Workshop for Space, Aeronautical and Navigational Electronics))
- Fast and Accurate 3-D Imaging Algorithm with Linear Array Antennas for UWB Pulse Radars
- A Robust and Fast Imaging Algorithm with an Envelope of Circles for UWB Pulse Radars(Sensing)
- A High-Resolution Imaging Algorithm without Derivatives Based on Waveform Estimation for UWB Radars(Sensing)
- An Accurate Imaging Algorithm with Scattered Waveform Estimation for UWB Pulse Radars(Sensing)
- A high-resolution imaging algorithm based on scattered waveform estimation for UWB pulse radar systems(Remote sensing/Radar (2), Workshop for Space, Aeronautical and Navigational Electronics (WSANE 2005))
- A high-resolution imaging algorithm based on scattered waveform estimation for UWB pulse radar systems
- B-8-29 The Influence of Linear Periodically Time-Variant Channels on PLC Equipments
- Effects of Tropical Rainfall to the Ku-Band Satellite Communications Links at the Equatorial Atmosphere Radar Observatory(CPEA-Coupling Processes in the Equatorial Atmosphere)
- Experimental study of high-range-resolution medical acoustic imaging for multiple target detection by frequency domain interferometry (Special issue: Ultrasonic electronics)
- Direct α-Hydroxylation of Ketones Catalyzed by Organic-Inorganic Hybrid Polymer
- Development of a Thomson Scattering System in the TST-2 Spherical Tokamak
- Ultrasound phantom using thin wires for the depiction of calcification: comparison of cross-sections of wire targets and mass targets (特集 医療・ヘルスケアにおける工学技術の新展開)
- Calculus detection for ultrasonography using decorrelation of forward scattered wave
- Fine Scale 3D Wind Field Observation With a Multistatic Equatorial Atmosphere Radar(CPEA-Coupling Processes in the Equatorial Atmosphere)
- Development of a multistatic atmospheric radar with digital receiver array(WSANE2006)
- SMALL CALCIFICATION DETECTION FOR ULTRASONOGRAPHY USING DECORRELATION BETWEEN RAW ULTRASONOGRAPHIC DATA
- An experimental study of ultrasonic imaging with a reduced number of array elements using the envelope method
- Small calcification depiction in ultrasound B-mode images using decorrelation of echoes caused by forward scattered waves
- An Imaging Algorithm of a Target with Arbitrary Motion for Ultra Wide-Band Radar with a Small Number of Antennas
- 3-D Fast Imaging Method for UWB Radar in Interference-Rich Environments with Global Optimization(WSANE 2008 (Workshop for Space, Aeronautical and Navigational Electronics))
- A Design Scheme for Electromagnetic Shielding Clothes via Numerical Computation and Time Domain Measurements(Analytical and Simulation Methods for Electromagnetic Wave Problems)
- Robust and Accurate Ultrasound 3-D Imaging Algorithm Incorporating Adaptive Smoothing Techniques
- Small calcification indicator in ultrasonography using correlation of echoes with a modified Wiener filter
- Ultrasound phantom using thin wires for the depiction of calcification: comparison of cross-sections of wire targets and mass targets (特集 医療・ヘルスケアにおける工学技術の新展開)
- Method for the Three-Dimensional Imaging of a Moving Target Using an Ultra-Wideband Radar with a Small Number of Antennas
- High Resolution Ultrasound Imaging Using Frequency Domain Interferometry : Suppression of Interference Using Adaptive Frequency Averaging (特集 医療関連電子技術のニュートピック)
- High Resolution Ultrasound Imaging Using Frequency Domain Interferometry : Suppression of Interference Using Adaptive Frequency Averaging
- Aberration Correction with Low-Frequency Transmission for Medical Acoustic Imaging
- Improved Spatial Resolution in a Three-Dimensional Acoustic Medical Imaging System Based on a Hybrid Method Using a Synthetic Aperture Technique
- Experimental Study of High-Range-Resolution Medical Acoustic Imaging for Multiple Target Detection by Frequency Domain Interferometry