Improved Spatial Resolution in a Three-Dimensional Acoustic Medical Imaging System Based on a Hybrid Method Using a Synthetic Aperture Technique
スポンサーリンク
概要
- 論文の詳細を見る
For an acoustic real-time three-dimensional (3-D) imaging system with high spatial resolution, we propose a system based on a hybrid method using a synthetic aperture technique. We can change the transmit point in this system; thus, the coherent integration of multiple receive signals from different transmit points improves spatial resolution using a synthetic aperture technique. In the case of a time resolution of 300 3-D images/s, the $-3$ dB lateral resolution of the proposed system is 1.30 $\lambda$ in the $x$–$z$ section and 1.17 $\lambda$ in the $y$–$z$ section for a 0.07 m depth, where the lateral resolution is improved from 16 transmit and receive events. The number of elements can be reduced to about 1/7.5 of a dense two-dimensional (2-D) array of a digital beamforming imager having the same time and spatial resolution.
- Published by the Japan Society of Applied Physics through the Institute of Pure and Applied Physicsの論文
- 2007-07-30
著者
-
TAKI Hirofumi
Graduate School of Infomatics, Kyoto University
-
SATO Toru
Graduate School of Infomatics, Kyoto University
-
Sato Toru
Graduate School of Informatics, Kyoto University, Kyoto 606-8501, Japan
-
Taki Hirofumi
Graduate School of Informatics, Kyoto University, Kyoto 606-8501, Japan
関連論文
- Experimental Study of Robust and High-Resolution Ultrasound Imaging Algorithm with Adaptive Smoothing Techniques(WSANE 2008 (Workshop for Space, Aeronautical and Navigational Electronics))
- Effects of Tropical Rainfall to the Ku-Band Satellite Communications Links at the Equatorial Atmosphere Radar Observatory(CPEA-Coupling Processes in the Equatorial Atmosphere)
- Direct α-Hydroxylation of Ketones Catalyzed by Organic-Inorganic Hybrid Polymer
- Calculus detection for ultrasonography using decorrelation of forward scattered wave
- Fine Scale 3D Wind Field Observation With a Multistatic Equatorial Atmosphere Radar(CPEA-Coupling Processes in the Equatorial Atmosphere)
- Development of a multistatic atmospheric radar with digital receiver array(WSANE2006)
- An experimental study of ultrasonic imaging with a reduced number of array elements using the envelope method
- Small calcification depiction in ultrasound B-mode images using decorrelation of echoes caused by forward scattered waves
- 3-D Fast Imaging Method for UWB Radar in Interference-Rich Environments with Global Optimization(WSANE 2008 (Workshop for Space, Aeronautical and Navigational Electronics))
- A Design Scheme for Electromagnetic Shielding Clothes via Numerical Computation and Time Domain Measurements(Analytical and Simulation Methods for Electromagnetic Wave Problems)
- Small calcification indicator in ultrasonography using correlation of echoes with a modified Wiener filter
- Ultrasound phantom using thin wires for the depiction of calcification: comparison of cross-sections of wire targets and mass targets (特集 医療・ヘルスケアにおける工学技術の新展開)
- High Resolution Ultrasound Imaging Using Frequency Domain Interferometry : Suppression of Interference Using Adaptive Frequency Averaging (特集 医療関連電子技術のニュートピック)
- High Resolution Ultrasound Imaging Using Frequency Domain Interferometry : Suppression of Interference Using Adaptive Frequency Averaging
- Aberration Correction with Low-Frequency Transmission for Medical Acoustic Imaging
- Improved Spatial Resolution in a Three-Dimensional Acoustic Medical Imaging System Based on a Hybrid Method Using a Synthetic Aperture Technique
- Experimental Study of High-Range-Resolution Medical Acoustic Imaging for Multiple Target Detection by Frequency Domain Interferometry