Data Recording on Dental Prostheses for Personal Identification
スポンサーリンク
概要
- 論文の詳細を見る
Data recording on a dental prosthesis for personal identification is proposed. Data recording was performed on a dental Au–Ag–Pd alloy with a complex surface shape by femtosecond laser processing with a surface detection function based on confocal optical detection. The processed morphology of a flat dental alloy sample was investigated over wide ranges of focus positions and laser fluences of the irradiating pulses. From the experimental results, appropriate recording conditions are discussed from the viewpoint of data recording. This is the first demonstration of two-dimensional data recording on such an object with a complex curved shape (an alloy crown).
- 2008-09-25
著者
-
ICHIKAWA Tetsuo
Department of Oral & Maxillofacial Prosthodontics and Oral Implantology, The University of Tokushima
-
Takita Akihiro
Department Of Optical Science And Technology Faculty Of Engineering The University Of Tokushima
-
Nagao Kan
Department Of Oral & Maxillofacial Prosthodontics And Oral Implantology The University Of Tokush
-
Hayasaki Yoshio
Department Of Optical Science And Technology Faculty Of Engineering The University Of Tokushima
-
Fujita Keiji
Department Of Optical Science And Technology Institute Of Technology And Science University Of Tokus
-
Fujita Keiji
Department of Optical Science and Technology, Faculty of Engineering, The University of Tokushima, 2-1 Minamijosanjima-cho, Tokushima 770-8506, Japan
-
Hayasaki Yoshio
Department of Optical Science and Technology, Faculty of Engineering, The University of Tokushima, 2-1 Minamijosanjima-cho, Tokushima 770-8506, Japan
-
Nagao Kan
Department of Oral and Maxillofacial Prosthodontics and Oral Implantology, Institute of Health Biosciences, The University of Tokushima, 3-18-15 Kuramoto, Tokushima 770-8504, Japan
-
Takita Akihiro
Department of Optical Science and Technology, Faculty of Engineering, The University of Tokushima, 2-1 Minamijosanjima-cho, Tokushima 770-8506, Japan
-
Fujita Keiji
Department of Applied Chemistry, Faculty of Engineering, Shizuoka University
関連論文
- New glass polyalkenoate temporary cement for cement-retained implant restoration : Evaluation of elevation and retentive strength
- Diagnosis, Prevention and Management for Aspiration Pneumonia in Dental Practice
- Treatment of a Renal Pelvic Tumor by a Transurethral Procedure
- Simplification of Space-Variant Parallel Logic Operations Using the Temporal Method
- Nonmechanical Optical Manipulation of Microparticle Using Spatial Light Modulator
- Osteopontin regulates adhesion of calcium oxalate crystals to renal epithelial cells
- Secure Information Display with Two Limited Viewing Zones Using Two Decoding Masks Based on Visual Secret Sharing Scheme
- Near-Infrared Spectroscopy Probe with Position Sensor
- Processing Structures on Human Fingernail Surfaces Using a Focused Near-Infrared Femtosecond Laser Pulse
- Influence of Changes in Occlusal Vertical Dimension on Tongue Pressure to Palate during Swallowing
- Optical Bit Recording in a Human Fingernail
- Surface Modification of Titanium with Hydrothermal Treatment at High Pressure
- Estimation of Residual Stress in Dental Porcelain by Laser-Raman Spectroscopy
- Stereoscopic Full-Color Light Emitting Diode Display Using Parallax Barrier for Different Interpupillary Distances
- In vitro Study of Stress Distribution on Additional Posterior Mandibular Implants
- Extracellular Matrix Formed by MC3T3-E1 Osteoblast-Like Cells Cultured on Titanium : II. Collagen Fiber Formation
- Extracellular Matrix Formed by MC3T3-E1 Osteoblast-Like Cells Cultured on Titanium : I. Anchor Structure
- Spatial and Temporal Properties of a Nonlinear Optical Feedback System
- Spatial Property of Formed Patterns Depending on Focus Condition in a Two-Dimensional Optoelectronic Feedback System
- Proximal-type epithelioid sarcoma of the perineum : Calling attention of urologists
- The Undergraduate Education of Removable Prosthodontics : A Comparison between the University of Birmingham (United Kingdom) and the University of Tokushima (Japan)
- Holographic Femtosecond Laser Processing with Multiplexed Phase Fresnel Lenses Displayed on a Liquid Crystal Spatial Light Modulator
- Influence of a Vent Hole on the Retentive Force of a Cement-retained Superstructure before/after Thermocycling
- Data Recording on Dental Prostheses for Personal Identification
- Femtosecond Pulse Laser-oriented Recording on Dental Prostheses : A Trial Introduction
- Classification System for the Completely Dentate, Partial and Complete Edentulism
- Carbon dioxide laser application enhances the effect of silane primer on the shear bond strength between porcelain and composite resin
- Denture Plaque Microflora in Geriatric Inpatients and Maxillary Defect Patients
- Adjustment of Depth of Field of Binocular Cameras for Reproducible Depth with Stereoscopic Light-Emitting Diode Display
- Processing structures on human fingernail surfaces using a focused near-infrared femtosecond laser pulse
- Optical bit recording in a human fingernail
- Two-Wavelength Phase-Shifting Low-Coherence Digital Holography
- Reaction of dimethyl 1-hydroxyalkylphosphonates with some chlorides.
- Survival of immediate implant restoration: A retrospective study through 9-year-observation
- A new method to prevent the corrosion of dental metals, during disinfection using functional water: Sacrificial protection
- MI sensor-aided screening system for assessing swallowing dysfunction: Application to the repetitive saliva-swallowing test