Purpose: Assessment of swallowing dysfunction, particularly the risk of aspiration, is extremely important to clinicians because it provides crucial information for preventing morbidity and mortality from dysphagia. The purpose of this study was to describe a magneto-impedance sensor-aided screening system (MISS) for assessing swallowing function and clarify its effectiveness with the repetitive saliva-swallowing test (RSST).Methods: An MI sensor attached to the skin over the sternum detected the distance from a magnet attached to the skin over the thyroid cartilage during swallowing as the change of magnetic fields. The MISS was validated by videofluoroscopic and videoendoscopic observations. Further, the swallowing behavior of 93 individuals was assessed by using the MISS and then analyzed with the RSST.Swallowing behavior can be recorded and investigated objectively by signal inspection in the MISS compared with the conventional methods. The MISS is a simple and straightforward method for recording and safe because of dry swallow.The MISS system was validated by using simultaneous recordings with videofluoroscopic or videoendoscopic examinations, and compared with the conventional RSST method.Conclusions: The MISS combined with the RSST is an effective screening test for swallowing function.
- 社団法人 日本補綴歯科学会の論文
著者
-
Akutagawa Masatake
Institute of Technology and Science, The University of Tokushima
-
ICHIKAWA Tetsuo
Department of Oral & Maxillofacial Prosthodontics and Oral Implantology, The University of Tokushima
-
Nagao Kan
Department Of Oral & Maxillofacial Prosthodontics And Oral Implantology The University Of Tokush
-
HONGAMA Seiko
Department of Oral & Maxillofacial Prosthodontics and Oral Implantology, The University of Tokushima
-
Tanida Kyuma
Institute of Technology and Science, The University of Tokushima
-
Toko Sachie
Department of Oral & Maxillofacial Prosthodontics and Oral Implantology, The University of Tokushima, Institute of Health Biosciences
-
Kinouchi Yousuke
Institute of Technology and Science, The University of Tokushima
関連論文
- Linear neural networks for spectral envelope estimation
- New glass polyalkenoate temporary cement for cement-retained implant restoration : Evaluation of elevation and retentive strength
- Diagnosis, Prevention and Management for Aspiration Pneumonia in Dental Practice
- Influence of Changes in Occlusal Vertical Dimension on Tongue Pressure to Palate during Swallowing
- Surface Modification of Titanium with Hydrothermal Treatment at High Pressure
- Estimation of Residual Stress in Dental Porcelain by Laser-Raman Spectroscopy
- In vitro Study of Stress Distribution on Additional Posterior Mandibular Implants
- Extracellular Matrix Formed by MC3T3-E1 Osteoblast-Like Cells Cultured on Titanium : II. Collagen Fiber Formation
- Extracellular Matrix Formed by MC3T3-E1 Osteoblast-Like Cells Cultured on Titanium : I. Anchor Structure
- The Undergraduate Education of Removable Prosthodontics : A Comparison between the University of Birmingham (United Kingdom) and the University of Tokushima (Japan)
- Influence of a Vent Hole on the Retentive Force of a Cement-retained Superstructure before/after Thermocycling
- Data Recording on Dental Prostheses for Personal Identification
- Femtosecond Pulse Laser-oriented Recording on Dental Prostheses : A Trial Introduction
- Classification System for the Completely Dentate, Partial and Complete Edentulism
- Carbon dioxide laser application enhances the effect of silane primer on the shear bond strength between porcelain and composite resin
- Denture Plaque Microflora in Geriatric Inpatients and Maxillary Defect Patients
- Inactivation of MS2 Phage and Cryptosporidium parvum Oocysts Using UV-A from High-Intensity Light-Emitting Diode for Water Disinfection
- Survival of immediate implant restoration: A retrospective study through 9-year-observation
- A new method to prevent the corrosion of dental metals, during disinfection using functional water: Sacrificial protection
- MI sensor-aided screening system for assessing swallowing dysfunction: Application to the repetitive saliva-swallowing test