Energy resolution measurements of ultraviolet-sensitive windowless silicon p–i–n photodiodes were carried out with alpha rays. A resolution of 12.6 keV in full width at half maximum for 5.486 MeV was achieved. The ultraviolet-sensitive silicon p–i–n photodiodes were found to be suitable to alpha-ray spectrometry.
- INSTITUTE OF PURE AND APPLIED PHYSICSの論文
- 2008-03-25
著者
-
Shibamura Eido
School Of Health And Social Services Saitama Prefectural University
-
Hasebe Nobuyuki
Research Institute for Science and Engineering, Waseda University, 3-4-1 Okubo, Shinjuku, Tokyo 169-8555, Japan
-
Hasebe Nobuyuki
Research Institute for Science and Engineering of Waseda University, 3-4-1 Okubo, Shinjuku-ku, Tokyo 169-8555, Japan
-
Mimura Mitsuteru
Research Institute for Science and Engineering of Waseda University, 3-4-1 Okubo, Shinjuku-ku, Tokyo 169-8555, Japan
-
Doke Tadayoshi
Kikui-Branch, Advanced Research Institute for Science and Engineering, Waseda University, 17 Kikuicho, Shinjuku-ku, Tokyo 162-0044, Japan
-
Shibamura Eido
School of Health and Social Services, Saitama Prefectural University, 820 Sannomiya, Koshigaya, Saitama 343-8540, Japan
-
Kobayashi Shingo
Research Institute for Science and Engineering, Waseda University, 3-4-1 Okubo, Shinjuku, Tokyo 169-8555, Japan
-
Kobayashi Shingo
Research Institute for Science and Engineering of Waseda University, 3-4-1 Okubo, Shinjuku-ku, Tokyo 169-8555, Japan
-
Miyajima Mitsuhiro
Research Institute for Science and Engineering of Waseda University, 3-4-1 Okubo, Shinjuku-ku, Tokyo 169-8555, Japan
関連論文
- Radiation Doses for Human Exposed to Galactic Cosmic Rays and Their Secondary Products on the Lunar Surface
- Time and Energy Responses of Liquid-Xenon Scintillation Chamber for ^Ne Ion Beam at 135A MeV
- Test of the Recombination Model for the Energy Resolution in an Ionization Chamber Filled with Liquid Argon or Xenon
- Angular Response of Photomultiplier Tubes : Photon-to-Electron Conversion Efficiency and Reflectance
- Improvement of Mass Resolution for Iron Isotopes in CR-39 Track Detector
- Mass Resolution for Iron Isotopes in CR-39 Track Detector
- Position Sensitive Element for Hypervelocity Microparticles Using a Piezoelectric Plate
- Ratio of Transverse Diffusion Coefficient to Mobility of Electrons in High-Pressure Xenon and Xenon Doped with Hydrogen
- Ratio of Transverse Diffusion Coefficient to Mobility of Electrons in High-Pressure Xenon
- Neutron production in the lunar subsurface from alpha particles in galactic cosmic rays
- Gamma-ray spectrometer (GRS) for lunar polar orbiter SELENE
- Complexities of gamma-ray line intensities from the lunar surface
- Electron Mobility and Longitudinal Diffusion Coefficient in High-Density Gaseous Xenon
- Density Dependence of the Longitudinal Diffusion Coefficient of Electrons in Xenon
- Measurements of Electron Drift Velocity in 3He Gas
- Average Numbers of Scintillation Photons and Electrons Produced by an Alpha Particle in High-Density Xenon Gas
- Performance of a Prototype of Liquid Xenon Scintillation Detector System for Positron Emission Tomography
- Performance of Prototype Liquid Xenon Scintillation Detector System for Time-of-Flight Type Positron Emission Tomography with Improved Photomultipliers
- Angular Response of Photomultiplier Tubes: Photon-to-Electron Conversion Efficiency and Reflectance
- Geochemistry and mineralogy of a feldspathic lunar meteorite (regolith breccia), Northwest Africa 2200
- Ultraviolet-Sensitive Windowless Silicon PIN Photodiodes for Alpha-Ray Spectrometry