Performance of Prototype Liquid Xenon Scintillation Detector System for Time-of-Flight Type Positron Emission Tomography with Improved Photomultipliers
スポンサーリンク
概要
- 論文の詳細を見る
The properties of liquid Xe are considered to be advantageous for application to time-of-flight positron emission tomography (TOF-PET). Previously, we constructed a prototype liquid Xe TOF-PET detector using photomultiplier tubes (PMTs), which can operate at liquid xenon temperature, and investigated their performance. Their poor quantum efficiency and low gain, however, were not sufficient for use in TOF-PET. Recently, new PMTs with five times higher quantum efficiency in liquid Xe and ten times higher gain than the previous PMTs have been developed by Hamamatsu Photonics Co. The prototype PET detectors, presented here, were constructed using these new PMTs and tested. An energy resolution of 15.9% (FWHM), a position resolution of 2.1–3.5 mm (FWHM), and a timing resolution of 260 ps (FWHM) were achieved.
- Published by the Japan Society of Applied Physics through the Institute of Pure and Applied Physicsの論文
- 2005-07-15
著者
-
Nishikido Fumihiko
Kikui-branch Advanced Research Institute For Science And Engineering Waseda University
-
Murayama Hideo
Kikui-branch Advanced Research Institute For Science And Engineering Waseda University
-
Takahashi Hidehiro
Kikui-branch Advanced Research Institute For Science And Engineering Waseda University
-
Kikuchi Jun
Kikui-branch Advanced Research Institute For Science And Engineering Waseda University
-
Ooshita Tatsuro
Kikui-branch Advanced Research Institute For Science And Engineering Waseda University
-
Mori Toshinori
Kikui-branch Advanced Research Institute For Science And Engineering Waseda University
-
Doke Tadayoshi
Kikui-Branch, Advanced Research Institute for Science and Engineering, Waseda University, 17 Kikuicho, Shinjuku-ku, Tokyo 162-0044, Japan
-
Takahashi Hidehiro
Kikui-Branch, Advanced Research Institute for Science and Engineering, Waseda University, 17 Kikuicho, Shinjuku-ku, Tokyo 162-0044, Japan
-
Murayama Hideo
Kikui-Branch, Advanced Research Institute for Science and Engineering, Waseda University, 17 Kikuicho, Shinjuku-ku, Tokyo 162-0044, Japan
関連論文
- Performance of Prototype Liquid Xenon Scintillation Detector System for Time-of-Flight Type Positron Emission Tomography with Improved Photomultipliers
- Performance of a Prototype of Liquid Xenon Scintillation Detector System for Positron Emission Tomography
- Time and Energy Responses of Liquid-Xenon Scintillation Chamber for ^Ne Ion Beam at 135A MeV
- Test of the Recombination Model for the Energy Resolution in an Ionization Chamber Filled with Liquid Argon or Xenon
- Mass Resolution for Iron Isotopes in CR-39 Track Detector
- Ratio of Transverse Diffusion Coefficient to Mobility of Electrons in High-Pressure Xenon and Xenon Doped with Hydrogen
- Ratio of Transverse Diffusion Coefficient to Mobility of Electrons in High-Pressure Xenon
- Performance of a Prototype of Liquid Xenon Scintillation Detector System for Positron Emission Tomography
- Performance of Prototype Liquid Xenon Scintillation Detector System for Time-of-Flight Type Positron Emission Tomography with Improved Photomultipliers
- Ultraviolet-Sensitive Windowless Silicon PIN Photodiodes for Alpha-Ray Spectrometry