Attenuation Compensation of Ultrasonic Wave in Soft Tissue for Acoustic Impedance Measurement of In vivo Bone by Transducer Vibration Method
スポンサーリンク
概要
- 論文の詳細を見る
In this paper, we describe a method of compensating the attenuation of the ultrasound caused by soft tissue in the transducer vibration method for the measurement of the acoustic impedance of in vivo bone. In the in vivo measurement, the acoustic impedance of bone is measured through soft tissue; therefore, the amplitude of the ultrasound reflected from the bone is attenuated. This attenuation causes an error of the order of $-20$ to $-30$% when the acoustic impedance is determined from the measured signals. To compensate the attenuation, the attenuation coefficient and length of the soft tissue are measured by the transducer vibration method. In the experiment using a phantom, this method allows the measurement of the acoustic impedance typically with an error as small as $-8$ to 10%.
- Published by the Japan Society of Applied Physics through the Institute of Pure and Applied Physicsの論文
- 2007-07-30
著者
-
Moriya Tadashi
Department Of Electrical Engineering Tokyo Metropolitan University
-
Yoshizawa Masasumi
Tokyo Metropol. Coll. Of Industrial Tech.
-
Nakamura Yuuta
Tokyo Metropol. Coll. Of Industrial Tech.
-
Ishiguro Masataka
Tokyo Metropol. Coll. Of Industrial Tech.
-
Moriya Tadashi
Department of Electrical Engineering, Tokyo Metropolitan University, 1-1 Minami-Ohsawa, Hachioji, Tokyo 192-0397, Japan
-
Nakamura Yuuta
Tokyo Metropolitan College of Technology, 1-10-40 Higashiohi, Shinagawa-ku, Tokyo 140-0011, Japan
関連論文
- Measurement of Speed of Sound in Skull Bone and Its Thickness Using a Focused Ultrasonic Wave
- Focusing Method in High-Impedance Material using Transmission Line Coupler : Ultrasonic Transmission Line Coupling Method
- Analysis of High-Lateral-Resolution Imaging Using Thin Quartz Fibers as Transmission Lines
- Development of a New System for Measuring Skull Bone Thickness by the Pulse compression Method
- Ultrasonic Flaw Detection for High Impedance Materials Using a Transmission Line Coupling Method
- High Signal-to-Noise Ratio Ultrasonic Point Detection Method using a Fused Quartz Rod as a Pulse Compression Filter and a Sensor
- Wide View-Angle Imaging Obtained by Compounding Multidirection Images through a Narrow Window
- Cost-Effective Unbiased Straight-Line Fitting to Multi-Viewpoint Range Data (Special Section of Selected Papers from the 9th Karuizawa Workshop on Circuits and Systems)
- Computing 2-D Motion Field with Multi-Resolution Images and Cooperation of Gradient-Based and Matching-Based Schemes
- Tracer for Ultrasonic Flow Visualization of Water/Solid Microparticle Suspension
- A Method for the Measurement of Acoustic Impedance and Speed of Sound in a Small Region of Bone using a Fused Quartz Rod as a Transmission Line
- A Method for Suppressing the Unwanted Signal Due to the L(0,2) Mode in an L(0,3) Mode Pulse Compression Filter by Means of a Tapered Cylindrical Fused Quartz Rod : Ultrasonic Transduction
- Measurement of Acoustic Impedance of Capsuled Tissue Sample by Interference Method using Fused Quartz Rod as a Transmission Line (国際セッションIS-EMD2002〔英文〕)
- P2-46 Attenuation Compensation of Soft Tissue for Acoustic Impedance Measurement of In Vivo Bone by Transducer Vibration Method(Poster session 2)
- Development of Scanning Method for Puncture Needle-Type Ultrasonography
- Processed skin surface images acquired by acoustic impedance difference imaging using the ultrasonic interference method : a pilot study
- Development of a Mechanical Scanning-type Intravascular Ultrasound System Using a Miniature Ultrasound Motor
- Imaging Method for Acoustic Impedance Difference for Puncture Needle-Type Ultrasonography using a Thin Rod with Focusing End Face
- Transducer Vibration Method for Interference-Based Reflection-Type In Vivo Measurement for Acoustic Impedance of Bone
- Attenuation Compensation of Ultrasonic Wave in Soft Tissue for Acoustic Impedance Measurement of In vivo Bone by Transducer Vibration Method
- Development of Robust Sensing System for Puncture Needle-Type Ultrasonography
- Analysis of High-Lateral-Resolution Imaging Using Thin Quartz Fibers as Transmission Lines
- Automatic Tracking of Region of Interest in Sonograms Using Respiratory Information
- Development of a New System for Measuring Skull Bone Thickness by the Pulse Compression Method