A measuring method of the three dimensional tooth displacement.
スポンサーリンク
概要
- 論文の詳細を見る
Biting force during functional movements applies stress to the teeth, periodontal ligament, mandible and maxilla and produces distortion in all of them. Schöhl (1960), Behrend (1974, 1978), Siebert (1980), Kato (1981, 1982), Miura (1985), and several other researchers have described the significance of the physiological tooth displacement during function and have measured it, which is a very complicated task. To assess such task, the three dimensional tooth displacement transducer type M-3 was developed. It consists of a transducer with three Magnesensors (three pick-up heads and three magnets, a universal joint, a measuring probe and a set-up plate. Its total weight is 48.7grs. The displacement transducer type M-3 is screwed into a paraocclusal splint, which is made up of a 2mm thick aluminium plate and autopolimerizing acrylic resin. This splint is fixed at the labial surface of the anterior teeth with a momentary adhesive. All parts of the transducer -except for the measuring probe- are extraoral, hence the normal masticatory movement, is not altered by its presence and also, the intraoral temperature and humidity do not affect the transducer.<BR>The free end of the 0.3mm diameter measuring probe is attached to the buccal middle surface of the tooth to be tested. Its movement in three directions is accuratory transmitted to the magnets by the universal joint. The displacement transducer type M-3 is contacting type, therefore some measuring pressure is essential, but since this measuring pressure must alternate with the physiological tooth displacement it should be kept as light as possible. As a result of using pivots in the universal joint, the measuring pressure was kept at less than 0.4grs. The linearity error of each transducer was less than 2% within a range of ±200μm. There was a minimum interference among the three transducers.<BR>It became possible to measure the three dimensional physiological tooth displacement during function.
- 日本顎口腔機能学会の論文
著者
関連論文
- 精神症状を有する患者に対する補綴診療
- 37. Apatite 2-piece implantの高度先進医療における臨床成績について
- Apatite 2-Piece Implant : 第3報 臨床治験について
- 2-3-2. ツーピースタイプ・アパタイト・インプラントの臨床術式について(第75回日本補綴歯科学会学術大会講演要旨)
- アレルギー患者に対する金・チタン合金を用いた原因除去療法
- 金属アレルギーと口腔内修復物の成分組成に関する調査
- 米国ノースカロライナ大学歯学部学生の研究活動の現状 : 主に東京医科歯科大学歯学部の現状との比較
- ノースカロライナ大学歯学部学生教育の現状
- 東京医科歯科大学歯学部附属病院第二補綴科受診患者の全身状態に関する臨床統計:「健康調査表」によるアンケート調査
- 歯牙の変位経路の三次元測定法について
- 咬合力による上顎臼歯部歯周組織の歪みの三次元的測定
- ブリッジを想定した連結固定が歯牙の変位経路に及ぼす影響
- Influence on the physiological tooth movement by splinting with bridge.
- A measuring method of the three dimensional tooth displacement.
- Histological investigation of improvement of jawbone structure for application of hydroxyapatite dental implant.
- Investigation of Metal Allergy to Constituent Elements of Intraoral Restoration Materials.
- A Survey on Condition of Outpatients at Prosthodontics II, University Hospital, Faculty of Dentistry, Tokyo Medical and Dental University.