透過性の膜で連結した二連のオリフィス型消音器の減音特性(透過損失の測定と理論解析)
スポンサーリンク
概要
- 論文の詳細を見る
This study deals with the attenuation characteristics of a double orifice silencer on ventilation holes. In this study, we inserted a tubular sheet of nonwoven fabric between the two orifices to improve the dip characteristics of the silencer. Then, we measured the sound transmission loss of the silencer with a four-microphone impedance tube. Simple double orifice silencers can be analyzed in one-dimension, but the acoustical analysis of the nonwoven fabric sheet is much difficult. In addition, in one-dimensional analysis, we must deal with the acoustical model with regard to the radial direction transparency of sound through the nonwoven fabric sheet. The sound transmission loss of the double orifice silencer, which bridged the nonwoven fabric sheet, was calculated via one-dimensional analysis. In addition, in this analysis, the acoustical constants of the nonwoven fabric sheets measured by the "two-cavity method" were installed in an equivalent circuit. It was observed that the analysis and the experimental results were in similar trend.
- 一般社団法人 日本機械学会の論文
著者
関連論文
- C-3-66 ガラス基板光導波型マイクロホンに関する研究 : S/N比の改善(光記録・計測(2),C-3.光エレクトロニクス,一般講演)
- C-3-62 おもり付きダイヤフラムを用いたシリコン基板光導波型加速度センサ : センサ感度の導波路位置依存性(光記録・計測(1),C-3.光エレクトロニクス,一般講演)
- C-4-10 共振器変調による半導体レーザの周波数安定化
- エタロンの透過・反射光を用いた半導体レーザの周波数安定化
- 音響を利用した中空光ファイバにおける漏洩検出(実験および理論解析)
- アレイ状の細管による消音構造を持つルーバにおける音響透過損失の理論解析と測定
- 細穴の集合体の寸法による吸音率と透過損失の推定(理論解析と実験結果の比較)
- 透過性の膜で連結した二連のオリフィス型消音器の減音特性(透過損失の測定と理論解析)