An Improved Quantization Scheme for Lattice-Reduction Aided MIMO Detection Based on Gram-Schmidt Orthogonalization
スポンサーリンク
概要
- 論文の詳細を見る
Lattice-reduction (LR) technique has been adopted to improve the performance and reduce the complexity in MIMO data detection. This paper presents an improved quantization scheme for LR aided MIMO detection based on Gram-Schmidt orthogonalization. For the LR aided detection, the quantization step applies the simple rounding operation, which often leads to the quantization errors. Meanwhile, these errors may result in the detection errors. Hence the purpose of the proposed detection is to further solve the problem of degrading the performance due to the quantization errors in the signal estimation. In this paper, the proposed quantization scheme decreases the quantization errors using a simple tree search with a threshold function. Through the analysis and the simulation results, we observe that the proposed detection can achieve the nearly optimal performance with very low complexity, and require a little additional complexity compared to the conventional LR-MMSE detection in the high Eb/N0 region. Furthermore, this quantization error reduction scheme is also efficient even for the high modulation order.
- The Institute of Electronics, Information and Communication Engineersの論文
著者
-
Fujino Tadashi
Department Of Cardiovascular Medicine Toho University Omori Medical Center
-
Hou Wei
Department of Communication Engineering and Informatics, The University of Electro-Communications
-
HOU Wei
Department of Information and Communications, The University of Electro-Communications (UEC)
-
KOJIMA Toshiharu
Department of Information and Communications, The University of Electro-Communications (UEC)
-
Kojima Toshiharu
Department of Communication Engineering and Informatics, The University of Electro-Communications
関連論文
- Resting Energy Expenditure and Substrate Metabolism in Chinese Patients with Acute or Chronic Hepatitis B or Liver Cirrhosis
- PE-050 Long-Term Prognosis of Permanent Inferior Vena Cava Filter in Deep Vein Thrombosis Associated with Pulmonary Thromboembolism(Thromboembolism/Thrombolysis 1 (IHD) : PE9)(Poster Session (English))
- PJ-665 Evaluation of Myocardial Bridge and its Proximal Regions on MDCT(CT / DSA(10)(I),Poster Session(Japanese),The 72nd Annual Scientific Meeting of the Japanese Circulation Society)
- PJ-798 Comparison between Long-acting and Short-acting Loop Diuretics in Chronic Heart Failure : Evaluation by I123MIBG(Heart failure, clinical-18, The 71st Annual Scientific Meeting of the Japanese Circulation Society)
- Characteristics of Congestive Heart Failure Accompanied by Atrial Fibrillation With Special Reference to Tachycardia-Induced Cardiomyopathy
- Effects of Continuous Hemodiafiltration for Cardiogenic Shock in Patients with Acute Myocardial InfarctionAcute Myocardial Infarction, Clinical (Pathophysiology) 6 (IHD), The 69th Annual Scientific Meeting of the Japanese Circulation Society)
- A Novel qR Complex in V1 Predicts Fatal Ventricular Arrythmias in AMI(Acute Myocardial Infarction, Clinical (Diagnosis/Treatment) 4 (IHD), The 69th Annual Scientific Meeting of the Japanese Circulation Society)
- Layer Error Characteristics of Lattice-Reduction Aided V-BLAST Detectors(Coding Theory,Information Theory and Its Applications)
- Lattice-Reduction-Aided Multiuser Detection for Space-Time Block Coded Multiple Antenna Systems
- Combined MMSE-SIC Multiuser Detection for STBC-OFDM Systems(Wireless Communication Technologies)
- Combined ML and MMSE Multiuser Detection for STBC-OFDM Systems(Communication Theory, Information Theory and Its Applications)
- BS-9-3 Combined MMSE and ML MUD for STBC-OFDM(BS-9. Broadband wireless communications techniques)
- B-5-20 Performance of Space-Time Block Code in a MIMO DS-CDMA System
- Herb Formula "Fufangqishe-Pill" Prevents Upright Posture-Induced Intervertebral Disc Degeneration at the Lumbar in Rats
- Optical and Structural Properties of Proton-Exchanged Waveguides in Y-Cut ZnO:LiNbO_3
- PJ-313 Cardiac Resynchronization Therapy Programming Using Impedance Cardiography(Heart failure, clinical(15)(M),Poster Session(Japanese),The 72nd Annual Scientific Meeting of the Japanese Circulation Society)
- A-5-6 Groupwise Successive ICI Cancellation for OFDM Systems in Time-Varying Channels
- B-5-54 Layer Error Characteristics of Lattice-Reduction Aided V-BLAST Detectors
- Optimal Dual-Chamber Pacing Therapy Improves Cardiac Function in a Patient with Complex Congenital Heart Disease and Bradyarrhythmias
- Current Status of Rate Control for Clinical Management of Patients with Atrial Fibrillation
- High Incidence of Inappropriate ICD Therapies in Young Patients with Catecholaminergic Polymorphic Ventricular Tachycardia
- A Young Case of IntraFascicular Ventricular Tachycardia with Narrow QRS Complex
- Assessment of the CHADS2 index and the Prevalence of Coronary Artery Disease in Patients with Atrial Fibrillation Desirable Ablation Procedure
- Quantization error reduction for MIMO detection based on orthogonal lattices
- Assessment of 123I-MIBG Scintigraphy as a Diagnostic Tool for Neurally Mediated Syncope
- Single-Ring Isolation Connecting Four Ganglionated Plexi of the Posterior Left Atrium as an Alternative Procedure for Eliminating Atrial Fibrillation
- An Improved Quantization Scheme for Lattice-Reduction Aided MIMO Detection Based on Gram-Schmidt Orthogonalization
- Low complexity MIMO detection using OSIC with conditional list generation