Application of Chemiluminescence Method in Clinical Analysis Using Immobilized Enzyme
スポンサーリンク
概要
- 論文の詳細を見る
Application of enzymes as an analytical tools has recently been an exponential increase particularly in the field of clinical chemistry. Among them, of special interest and importance is the use of immobilized enzymes, which offer several advantages over conventional methods with soluble enzymes: thermal stability, resistance to decomposition and ease to assemble in an automatic instrument.<BR>On the other hand, many clinically important compound in blood are oxidized by an individual oxidase with concomitant formation of hydrogen peroxide. For the detection of enzymically generated hydrogen peroxide, luminol chemiluminescence method is the most favorable because of its high sensitivity, wide linear dynamic range and simple instrumentation. Furthermore the reagents are relatively inexpensive and stable, therefore, this enable us to couple the enzymic process and the chemiluminescence detection process through the continuous flow system. This is very important because the use of an immobilized enzyme column is probably only one possible way to perform the enzyme catalyzed process in the continuous flow system.<BR>As the first step toward the development of an automatic multichannel enzymic analyzer, we have assembled an apparatus which enable us to analyze glucose and uric acid in blood sample with high sensitivity. The appratus consists of immobilized oxidase column and chemiluminescence detector. All reagents, luminol, ferricyanide and buffer solutions, are supplied continuously by a peristaltic pump, and blood samples are introduced into enzyme column from an autosampler or injected by microsyringe. In the enzyme column, glucose oxidase or uricase, which are immobilized onto long chain alkyl amine glass by the cyanogen bromide method, are packed.<BR>Enzymically formed hydrogen peroxide are mixed with chemiluminescence reagents in a swirling cell mounted directly on the surface of window of photomultiplier.<BR>This apparatus has been found to be successfully applied for the quantitative determination of glucose and uric acid in blood samples in a range between 10<SUB>-8</SUB> and 10<SUB>-4</SUB> M.<BR>By slight modification of the apparatus NAD (P) H was also determined using methylene blue as an electron carrier between NAD (P) H and oxygen. This system responded to the concentration of NAD (P) H down to 10<SUB>-8</SUB> M.
- Japan Society of Clinical Chemistryの論文
著者
-
佐伯 行一
滋賀医科大学実験センター
-
野崎 光洋
滋賀医科大学医学部
-
田畑 勝好
京都大学医療技術短期大学部
-
村地 孝
京都大学医学部病態学教室
-
岡西 哲雄
滋賀医科大学医学部
-
佐伯 行一
滋賀医科大学
-
野崎 光洋
滋賀医科大学
関連論文
- 2F167 遊離型血中濃度測定によるフェニトインの代謝に関する研究
- 固定化乳酸脱水素酵素とNADHとの反応の解析
- 伸展刺激および高脂血症が血管平滑筋細胞の増殖に及ぼす影響
- ヒト羊水中肺活性物質の新しい測定法 : dipalmitoylphosphatidylcholineの酵素的定量ならびにその臨床応用
- 酸素添加酵素 : 酸素の活性化(化学における発明発見 : その芽と発展)
- Usefulness of Glucokinase from Bacillus stearothermophilus for the Enzymatic Measurement of Magnesium in Human Serum
- 検査試薬としての酵素の使い方
- 第40回日本臨床病理学会近畿支部例会のまとめ -老人病(老化)と臨床検査-
- 診断用高分子検査試薬
- 固定化酵素リアクタ---化学発光の応用 (診断用バイオリアクタ-)
- 酵素を用いた臨床化学分析 (1983年の化学-11-)
- 医学・生物学分野における固定化酵素 (バイオマテリアルサイエンス-1-酵素,抗体,細胞の機能制御とその応用) -- (生体高分子の機能制御)
- 固定化酵素-医用高分子としての新展開
- 金属酵素の構造と作用 (生化学的立場から) について
- 臨床化学分析用バイオセンサー
- 高分子に結合した補酵素の臨床化学分析への応用 : 第32回大会シンポジウム(臨床検査領域での酵素,特にビタミン関連酵素の応用)
- A Development of Emergency Assay for Blood Levels of Pyruvate Kinase and a Significance for Enzymic Diagnosis of Acute Myocardial Infarction
- A Simplified Colorimetric Assay for Blood Levels of Pyruvate Kinase and Its Clinical Application
- Application of Chemiluminescence Method in Clinical Analysis Using Immobilized Enzyme
- Application of Chemiluminescence in Clinical Chemistry