微小心筋灌流分布の灌流液依存性 (血液vs. Tyrode溶液)
スポンサーリンク
概要
- 論文の詳細を見る
We compared the spatial patterns of regional myocardial flows between crystalloid and blood perfused hearts, we measured within-layer regional myocardial flow distributions of Tyrode- and blood-perfused hearts using a molecular flow tracer, tritiated-desmethylimipramine (HDMI). Isolated rat hearts were perfused with Tyrode solution (Tyrd; n=7) or blood (Bld; n=14) at the 100 mmHg head pressure. After the peak reactive flow following 30 s flow-shutoff-reperfusion was measured, HDMI (2μCi) was injected into the perfusion line. A 60 s continuous injection was performed in seven and a bolus injection in seven hearts out of the fourteen Bld hearts and in Tyrd hearts. The left ventricular free wall was then sliced into 10 μm thick slices from subepi- to subendocardium. The distribution of HDMI density, i. e., within-layer relative flow, was measured in twenty-eight slices per heart by quantitative digital radiography with 100μm pixels. The coefficient of variation of flows (CV=SD of pixel tracer density/mean tracer density) was used to quantitate perfusion heterogeneity. In Tyrd and Bld, perfusion rates were 13.6±2.7 and 2.8±0.6 ml/min/g, respectively. The maximum percent increase of flow rate after the reperfusion was larger in Bld than in Tyrd (71±21% vs. 15±9%). CV was considerably higher in Bld than in Tyrd. In Bld, the continuous tracer injection yielded a smaller CV than the bolus injection. These CV differences were consistent over the resolution range of 100-800, μm. These data suggest that more preserved higher vasomotor tone and therefore higher flow resistance in blood-perfused hearts will be responsible for higher flow heterogeneity. The reduced CV under continuous tracer injection in blood-perfused hearts implies the short-term, temporal fluctuation of vasomotor tone and/or stochastic behaviors of the corpuscles in microvessels.
- 日本バイオレオロジ-学会の論文
著者
関連論文
- 25.人工赤血球灌流時の心筋潅流状態の計測(第26回中国四国支部大会抄録)
- ラット交叉潅流モデルを用いたリポソーム型人工赤血球の局所心筋潅流特性の評価 : 分子トレーサ法を用いた検討
- 533 ラット交叉潅流モデルを用いたリポソーム型人工赤血球の局所心筋潅流特性の評価
- 微小心筋潅流分布の潅流液依存性 : 血液 vs. タイロード溶液 分子トレーサ法による心筋デジタルラジオグラフィ
- 0827 肥大型心筋症と高インスリン血症との関連
- 分子血流トレーサによる心筋微小循環血流計測と血流 microheterogeneity
- ダブル分子トレーサ法による低潅流下心筋内微小循環の評価 : 交叉潅流モデルによる心筋血流分布デジタルラジオグラフィ
- 微小心筋潅流分布の潅流液依存性(血液 vs. タイロード溶液) : 分子トレーサ法による検討
- 分子トレーサ・デジタルラジオグラフィ : 心筋微小循環血流イメージング
- ダブル分子トレーサによる心筋血流デジタルラジオグラフィの血液交叉灌流心への応用
- ダブル分子トレーサを利用した低酸素潅流心における心筋潅流不均一性の解析
- 微小心筋灌流分布の灌流液依存性(血液vs.Tyrode溶液)--分子トレーサ法による検討
- P016 最小冠血流調節ユニットサイズの心筋変形は不均一である
- 微小心筋灌流分布の灌流液依存性 (血液vs. Tyrode溶液)