ポリメタクリル酸メチル延伸フィルムのガラスーゴム転移と熱収縮
スポンサーリンク
概要
- 論文の詳細を見る
Hereunder is presented a report of an experiment made of polymethyl methacrylate films that were stretched to a predetermined length at 140°C in a silicone oil bath, and kept at the temperature, until the stress relaxed adequately. The temperature was then lowered stepwise, leaving the films at certain fixed length. At each temperature the sample was kept for about 30 minutes. Observations were enacted of various specimens with different extensions with respect to their reversible stress vs. temperature relations; the glass-rubber transition temperature decreased linearly with increasing extension (102°C and 98°C for 16% and 120% extension, respectively). The volume of the specimens increases slightly with stretching, and this could be interpreted reasonably by considering that the configurational entropy should be frozen at a constant value in glassy state; it relates to the number of holes in the system.<BR>The film held at constant length was cooled to room temperature below T<SUB>g</SUB>, then the stress was removed; its length almost remained unchanged. The specimen thus obtained was heated in the bath, and the length vs. temperature relation was measured. It began to shrink abruptly at the transition temperature and the length changed irreversibly to an equilibrium value. The transition point varied more rapidly with extension than that in the reversible stress vs. temperature relation (106°C and 97°C for 16% and 120% extension, respectively, at a heating rate of 1°C per minute). It depends on the heating rate; the slower the heating, the lower the temperature is. The time effects on the recovery were measured at various temperatures in the transition region for 5% and 40% extended samples. The isotherms were closely superposable by horizontal shifts. Temperature dependence of the logarithmic shift factors (loga<SUB>T</SUB>) was in fair accord with the WLF equation for the temperature range below 115°C, but diverged from the equation at higher temperatures.<BR>In case the specimen with previous history was fixed at constant length and heated, no stress was observed in the temperature range below T<SUB>g</SUB>. The stress due to thermal shrinkage was observed, however, at several degrees above the transition temperature; the value increased and the temperature where it appeared decreased with increase in the extension. The time effects were also measured of various extensions in this case, but they behaved in very complicated manner. The mechanism of the thermal stress could be explained qualitatively based on a thermodynamic consideration.
- 社団法人 日本材料学会の論文
著者
関連論文
- 未熱処理ポリエチレンテレフタレ-ト延伸フィルムの熱収縮
- 延伸ポリマーの熱収縮とガラス転移
- スラックスの拘束性に関する研究
- Bellows action(ふいご作用)の着衣の放熱性能への影響 第1報 衣服下間隙寸法と通気性の効果
- 着衣時の皮膚露出部の熱伝達への端部開口部の効果-模擬皮膚による検討-
- 着衣の熱・水分同時移動への布の通気性, 透湿性による影響
- 繊維と私
- 学会あれこれ
- 祖父江 寛先生 SOBUE Hiroshi -化学繊維の進展とともに-
- 無定形高分子の体積粘弾性
- 3a-G-5 高分子物質の融解とガラス転移
- ポリエチレン分子の音響的配向評価
- 無定型高分子の熱膨張および圧縮率
- P.V.C.シートの衝撃引張特性 : 高分子のレオロジー
- レーヨンの引張強度について : 高分子のレオロジー : レオロジー特集号
- 紡績繊維の動的挙動の吸湿度依存性 : 高分子レオロジー
- 再生セルロース繊維の湿潤時の粘弾性 : 高分子レオロジー
- 模擬皮膚からの熱伝達 : 模擬皮膚湿潤時と乾燥時の比較
- 衣服素材の通気性と放射特性が着衣系の熱伝達に及ぼす効果〔英文〕 (感覚と計測)
- 繊維の伸張と動的弾性率
- 着衣の保温性への下端開口部の効果 -模擬皮膚による検討-
- 布の透湿性
- 被服の拘束に関する基礎的検討 : 摩擦の寄与
- 縫いつけ法による洗濯時の布にかかる張力測定法の提案
- 布透湿性の基礎的検討
- 被服科学研究委員会報告
- 21世紀に向けて
- テキスタイルと情報
- 日本の繊維・高分子科学の先駆者 祖父江先生
- 被服学のあれこれ
- 仕上げ過程における紡毛布地の空隙構造変化
- ポリメタクリル酸メチル延伸フィルムのガラスーゴム転移と熱収縮
- 繊維・織物の衝撃強さ
- 繊維の疲労について (ゴム用繊維の最近の諸問題)