健常者の柔軟性に関する衛生学的研究 : その3 測定方法論
スポンサーリンク
概要
- 論文の詳細を見る
For the research on test and measurement, the evaluation of measurement error is inevitable. The basic data for evaluation are obtained by the process of measurement, and also, for better evaluation, it is very important to evaluate the measurement error and causes of error. At the evaluating processes, such error must be considered reasonably. Therefore, the error which is included in flexibility measurement is discussed in this paper by the way of analysis of variance. At the same time, by the way of analysis of variance, the objectivity of flexibility measurement which is done by angular-method is discussed, too. In other words, through the computation of measurement error which is caused by repetition of measurement carried by the same testee and also through the computation of measurement error which is caused by repetition of measurement carried by the different testers, the measurement error is investigated.1) The measurement error of trunk flexion is 1.7 degree for angular-method and 2.0cm for distance-method at the five repetitions, and also 1.5 degree and 1.7cm at the three repetitions, respectively.2) For the trunk flexion measurement, such measurement values as dropping into the interval x±1.7 degree is thought as the good representative value of measurement. This interval is called as a sort of critical region.3) Through the above mentioned investigation, the measurement error affects the first digit of degree unit and also first digit of cm unit, respectively. Therefore, it is good enough only to read the degree unit and cm unit at angular-method and distance-method, respectively.4) At the comparison of measurement error between trunk flexion and extension, it is the least for trunk flexion and the most for trunk extension, and medium for trunk sideward bend. Furthermore, the extent to which the measurement error is included in the mean value of each measurement item tends to show the same thing.5) At the comparison of measurement error which is caused at three-times-repeated and fivetimes-repeated measurement of angular-method the significant difference of measurement error could not be found. However, in general, the measurement error ranging from minimum, 1.5 degree to maximum, 3.5 degree is found. Minimum error, 1.5 degree was found at trunk flexion, and maximum one, 3.5 degree was found at trunk extension.6) Analysis of variance was applied to the trunk flexion, extension and sideward bend data, the differences of measurement error due to different testees are not significant statistically, at significance level 0.01 and 0.05. In other words, any difference between testees do not influence to measurment error variation.7) And also, the differences of measurement error due to different testers are not significant statistically at significance level, 0.01 and 0.05. In other words, the extent of measurement error variation does not influence to the measures significantly. Therefore, this means that this test is highly objective.
- 日本衛生学会の論文
著者
関連論文
- 筋の持久力に関する研究(II) : 筋持久力の評価方法についての検討
- 運動能力の発達に関与する諸要因の因子分析的研究
- 体操訓練の柔軟性に及ぼす実験的研究 : その8
- 健常者の柔軟性に関する衛生学的研究 : その5 柔軟性測定法の標準化
- 身体柔軟性のX線学的研究(その7)
- 219. 和・洋弓のエネルギー代謝に関する研究 第1報 : 和弓について
- 602. 運動能力の発達を制約する諸要因に関する検討
- 601. 体位の発育を制約する諸要因の検討 : 因子分析法による
- 生体の発達に対する各種運動の作用度 (第5報)
- 健常者の柔軟性に関する衛生学的研究 : その3 測定方法論
- 健常者の柔軟性に関する衛生学的研究 : その2. 測定方法論
- 健常者の柔軟性に関する衛生学的研究 : その1.測定方法論
- 学徒のエネルギー代謝と栄養摂取に関する研究-1-