金属ウラン中の亜鉛の定量法
スポンサーリンク
概要
- 論文の詳細を見る
For determination of zinc in metallic uranium by the dithizone extraction method, the effect of pH on the extraction of zinc-dithizone complex, the concentration of dithizone, and the liberating agent for elusion of adsorbed dithizone complex from alumina column have been investigated and tha following method of determination was established.<BR>The sample was dissolved in hydrochloric acid and hydrogen peroxide, it was evaporated to dryness, the residue was treated with ammonium citrate for masking of uranium, aqueous ammonia was added to adjust pH 8.5±0.3, and zinc was extracted as dithizone complex into carbon tetrachloride.<BR>The extracted solution was passed through an alumina adsorption column, washed with chloroform for removing of dithizone complexes of nickel and cobalt, the zinc was liberated by use of chloroform-methanol and determined by measuring the light absorbance at 480mμ. Determination of 0.28γ of Zn/5m<I>l</I>. was made by the proposed method.
- 社団法人 日本分析化学会の論文
著者
関連論文
- 金属ウラン中の銅の定量 : 金属ウラン中の微量物質の分析法(第5報)
- 金属ウラン中のカドミウムの定量法 : 金属ウラン中の微量物質の分析法(第2報)
- 金属ウラン中のマグネシウムの定量
- 金属ウラン中のニッケルの定量法
- 金属ウラン中のコバルトの定量法
- 金属ウラン中のモリブデンの迅速定量法
- セシウムおよびフランシウムのテトラフェニルボロン溶媒抽出法
- 金属ウラン中の亜鉛の定量法
- ビスマスのジチゾン抽出による鉛-210の定量法
- 金属ウラン中のケイ素およびリンの迅速定量法
- ポロニウムのジチゾン抽出定量法
- 四フッ化ウラン中のウラン(VI)の定量
- 金属ウラン中のヒ素の定量