113mInゼネレーター調製のための酸化ジルコニウムの比較検討
スポンサーリンク
概要
- 論文の詳細を見る
In order to determine the separability of <SUP>113m</SUP>In from <SUP>113</SUP>Sn-<SUP>113m</SUP>In, the adsorption behavior of these radionuclides for zirconium oxide were compared with those for hydrous zirconium oxide (HZO) under a variety of experimental conditions. From the batch distribution coefficients, the separability for these adsorbents was shown to be nearly equal over the concentration range of hydrochloric acid as an external solution from 6.1 × 10<SUP>-2</SUP> to 2.6 × 10<SUP>-1</SUP> <I>M</I>. It was shown from the column study that 7085% of <SUP>113m</SUP>In free from <SUP>113</SUP>Sn was recovered either from HZO column by passing through the hydrochloric acid solutions over the concentration range from 6.1 × 10<SUP>-2</SUP> to 2.6× 10<SUP>-1</SUP> <I>M</I> or from zirconium oxide column from 3.7 × 10<SUP>-2</SUP> to 4.2 × 10<SUP>-1</SUP> <I>M</I>. The merit of zirconium oxide over HZO is that the former is inexpensive, affords wide concentration range of the eluate and keeps zirconium well from breaking through the column. X-Ray diffraction patterns of zirconium oxide were considerably different from those of HZO.
- 社団法人 日本分析化学会の論文
著者
関連論文
- ポーラス型無水マレイン酸-ジビニルベンゼン球状共重合体を用いる反応ガスクロマトグラフィーによる第一級及び第二級アミンの除去
- 環境放射能分析への無機イオン交換体の応用
- 環境試料処理に関連する問題 : 乾式灰化と発煙硝酸を使わない放射性ストロンチウムの定量
- キレート試薬共存による68Ge,68Gaのアルミナへの吸着挙動
- 放射能分析 (分析化学進歩総説1967年版)
- 113mInゼネレーター調製のための酸化ジルコニウムの比較検討