微分ガスクロマトグラフ法によるカラム温度の適否の判別
スポンサーリンク
概要
- 論文の詳細を見る
The effect of sample amount and column temperature on the shape of chromatographic peak and the retention time was investigated experimentally by means of a derivative method.<BR>As well known, Cruickshank and Everett proposed to express the peak distortion by skew ratio, <I>R</I>, shown by eqn. (1) and Fig. 1. The skew ratio can simply be measured in the derivative method as the ratio of the derivative peak heights, as given by eqn. (2). In the present work, the peak distortion was discussed in terms of the degree of asymmetry, <I>S</I>, defined as the logarithm of skew ratio.<BR>A close correlation between the shift of retention time and the distortion of peak shape was observed, especially when the column temperature was too high or too low, and this tendency became more remarkable with increasing amount of sample injected.<BR>As shown in Fig. 3, when the column temperature is lower than the optimum one, with increasing sample amount the peak shows a leading shape more prominently and the retention time becomes longer. On the contrary, when the temperature is higher, a more remarkable tailling of the peak is observed and the retention time becomes shorter. The experimental conditions and the data obtained are given in Figs 5 9.<BR>As tabulated in Table II, it was confirmed experimentally with several samples that there is a temperature <I>T</I><SUB>1</SUB>, at which the degree of asymmetry <I>S</I> does not depend on the amount of sample injected. At this optimum temperature, the degree of asymmetry shows a value <I>S</I>° that lies very closely to zero. Further, a temperature <I>T</I><SUB>2</SUB>, at which the retention time shows a constant value independent of the sample amount injected was measured. Two optimum temperatures <I>T</I><SUB>1</SUB> and <I>T</I><SUB>2</SUB> were found to be almost identical in the range of experimental error.<BR>It can be judged simply and rapidly whether the column temperature is suitable or not from these results. For a given sample component under a certain column packing condition, if <I>S</I>°, i. e. the least value of degree of asymmetry, is known, one can easily find whether the temperature is higher or lower than the optimum one, from the measurement of <I>S</I> under the given temperature, as tabulated in Table III. If <I>S</I>° has not been evaluated, by comparing two values of <I>S</I>, namely, <I>S</I><SUB>A</SUB> obtained for A-μ<I>l</I> sample and <I>S</I><SUB>B</SUB> for B-μ<I>l</I> sample, respectively, one can know the suitability of the column temperature.<BR>Most simply, if the absolute value of <I>S</I> be nearly zero, one may judge that the column temperature is not far from the optimum. Thus, it could be said that by an aid of the derivatives gas chromatographic method one can easily obtain an important information concerning the column temperature. An example with a three-component mixture is reproduced in Fig. 10.
- 社団法人 日本分析化学会の論文
著者
関連論文
- 溶媒抽出に関するデータベースの構築
- 液体クロマトグラフィーの固定相としてのポリエチレンの特性
- サイズ排除クロマトグラフィー/黒鉛炉原子吸光法による原油中のバナジウム分及びニッケル分の分別と定量
- 種々のβ-ジケトンのβ,β'-オキシジプロピオニトリル化学結合充てん剤上での液体クロマトグラフ挙動
- 第6回日ロ分析化学シンポジウム
- 金属錯体の液体クロマトグラフィー
- 微分ガスクロマトグラフ法によるカラム温度の適否の判別