真空ポンプ油の蒸気圧
スポンサーリンク
概要
- 論文の詳細を見る
This brief paper presents the vapoure pressure data of the following fluids used in vacuum pumps : DC 704, DC 705, Apiezon B, Apiezon C, Lion A, Di - 2 -ethylhexyl phthalate (DEHP), Di-2-ethyl- hexyl sebacate (DEHS), Cellulube 220, Cellulube 300, Convalex 10, and OS 124. Measurements have been made in the pressure range of 0. 5 to 20 Torr with the oil-manometer in which the samples themselves are used. It has been previously reported for this method to be most suitable in the case of measuring the vapour pressures of the vacuum pump oils near at a boiler temperature (J. Vac. Soc. Japan 1 222 (1958)). In discussion, the data obtained in study have been compared with those by other investigators. Consequently, it is proved that, this for each sample, all these data measured in the different range of pressure can be suffici-ently plotted on a line expressed by the equation, log P= a-b/T c log T.
- 日本真空協会の論文
著者
関連論文
- 油蒸気の汚染による電離真空計の感度喪失現象
- 高真空用油に於ける気体の吸収速度 II : 真空
- 超高真空中が得られる新らしい拡散ポンプ油 : 測定技術(真空技術)
- 高真空用油における気体の吸収I : 測定技術(真空技術)
- マクラウド真空計毛細管中における水銀糸の挙動について
- B-A形真空計を利用したピラニ真空計
- 真空ポンプ油として使用された合成コンプレッサ油Cellulube 220および300について
- モンテカルロ法によるクライオポンプ排気速度の算出
- 拡散ポンプ用シリコーン油の合成
- トラップを用いたマクラウド真空計による真空度測定の根本的欠陥について
- 油エゼクタポンプ油の熱分解の研究
- 新しいオージェ電子放射の応用 とくに固体表面の微量元素分析について
- 真空計の校正と真空度標準-2-
- 真空ポンプ油の蒸気圧
- 真空用油のガス含有量
- 副標準電離真空計VS-1型の高真空側における使用限界
- 電離真空計の測定における室温の影響
- 計量法の改正と圧力の単位