Breakdown Voltage of CO2 at Temperatures around 4000K and in Range from 300 to 700K
スポンサーリンク
概要
- 論文の詳細を見る
The breakdown voltage of high temperature CO2 was measured at temperatures around 4000K and in the temperature from 300 to 700K at an absolute pressure of 0.1MPa. A voltage was applied to the high temperature CO2 through a set of two rod electrodes made of stainless steel with a diameter of 2mm. The gap length between the electrodes was adjusted to be of 1mm. The breakdown voltage of the hot CO2 proved to decrease in inverse proportion to the increase in temperature, in the range from 300 to 700K. Further increase in temperature of the CO2 reduced the breakdown voltage more markedly. For example, at 4000 K the breakdown voltage was measured to be of 55V. This breakdown voltage is only 1.1% of that at room temperature.
- 社団法人 電気学会の論文
著者
-
Yamamoto Kazuma
Department Of Electronic Engineering Faculty Of Engineering Tohoku University:laboratory For Microel
-
Ohta Daisuke
Department Of Breast Cancer Research Tokyo Metropolitan Cancer Detection Center
-
Matsumura Toshiro
Department of Electrical Engineering and Computer Science, Nagoya University
-
SHIBUYA Masatoyo
Central Research Institute of Electric Power Industry
-
Matsumura T
Department Of Electrical Engineering And Computer Science Nagoya University
-
Matsumura Toshiro
Department Of Electrical Engineering And Computer Science Nagoya University
-
Yokomizu Y
Department Of Electrical Engineering And Computer Science Nagoya University
-
Yokomizu Yasunobu
Department Of Electrical Engineering And Computer Science Nagoya University
-
Almiron Pablo
Department of Electrical Engineering and Computer Science, Nagoya University
-
Yamamoto Kazuma
Department of Electrical Engineering and Computer Science, Nagoya University
-
Ohta Daisuke
Department of Electrical Engineering and Computer Science, Nagoya University
関連論文
- Development of Multiple Power Quality Supply System
- Silicon Wafer Orientation Dependence of Metal Oxide Sermiconductor Device Reliability
- Arc parameters around current zero in CO2-blast quenching chamber and their dependences on filled pressure (特集 アークプラズマ・電気接点とその応用)
- Evaluation of Sensitivity to 5-FU on the Basis of Thymidylate Synthase (TS)/Dihydropyrimidine Dehydrogenase(DPD) Activity and Chromosomal Analysis in Micro Tissue Specimens of Breast Cancer
- Mammary Ductoscopy for Diagnosis and Treatment of Intraductal Lesions of the Breast
- Cancer stem cells and chemoradiation resistance
- An American Woman's Experience of Absolute Bed Rest
- The Neurotics among Teachers Treated by the Morita Therapy with Hospitalisation
- Severe steatosis resulted from anorexia nervosa leading to fatal hepatic failure
- Formulated representation for upper limitation of deliverable power in low-voltage DC distribution system (特集 電力・エネルギー分野における直流応用技術)
- Derivation of Receivable Power of Electronic Loads Connected to DC Distribution System on the Basis of Stability Criterion
- Evaluation of Breaking Capability of a Hybrid Fault Current-Limiting Circuit Breaker Based on Mayr-Type Arc Model
- Estimation of Current Interruption for a Circuit Breaker Associated with Inductive Current-Limiter based on Mayr Model
- Effect of a Fault Current Limiter on Interrupting Condition under Breaker Terminal Fault Regime
- Effect of Fault Current Limiter on Transient Recovery Voltage across a Circuit Breaker under Breaker Terminal Fault Condition
- Conductance Diagnostics in Hot Gas Ejected from a Molded Case Circuit Breaker during High Current Arc Interruption
- Formulated representation for upper limitation of deliverable power in low-voltage DC distribution system (特集 電力・エネルギー分野における直流応用技術)
- Correlation between interrupting capability and airflow velocity distribution in flat-type arc quenching chamber
- Total Voltage Drops in Electrode Fall Regions of SF6 Arcs between Electrodes of Cu-W,Cu,Fe,Ti,C and W in Current Range from 10 to 20000A (特集:ガス絶縁およびガス絶縁機器)
- Increase of Inductance Ratio of Flat Type Fault Current Limiter with High-T_c Superconducting Disk
- Required Limiting Impedance and Capacity of Fault Current Limiter Installed in Customer System with Synchronous Generator
- Limiting Impedance of Flat Type Fault Current Limiter with High Tc Superconducting Plate (特集:電力・エネルギー分野を支える静止器技術の新展開)
- Arc Behavior in Rotary-arc Type of Load-break Switch and its Current-interrupting Capability for Different Environmentally Benign Gases and Electrode Materials
- Arc behavior in rotary-arc type of load-break switch and its current-interrupting capability for different environmentally benign gases and electrode materials
- Relationship between Rate of Rise of Recovery Voltage across a Breaker Connected with Fault Current Limiter and Current for Zero-Kilometer Fault Regime
- Thermodynamic Properties at High Temperatures and Particles Present After Arc Extinction in CO_2-CF_3I Mixture
- Particle composition of CO2-CF3I mixture at temperatures of 300-30,000K (特集 IWHV 2007 (5th International Workshop on High Voltage Engineering))
- Thermodynamic, Transport and Radiation Properties of High-temperature CF_3I and Transient Conductance of Residual Arc Sustained in Axial CF_3I Flow
- Influences of Opening Velocity of Electrodes and Arc Column Length on Direct-current Breaking Capability of Arc Device
- Breakdown Voltage of CO2 at Temperatures around 4000K and in Range from 300 to 700K
- Anode-fall Voltages of Air Arcs Between Electrodes of Copper, Silver and Tungsten at Currents up to 1500A
- Thermal Breakdown in High Temperature CO_2 and Air Impressed with DC Voltage at Atmospheric Pressure
- Anode-fall voltages of Air Arcs Between Electrodes of Cu, Ag and W at Currents up to 1500A
- Direct Determination of Lead in Suspended Particulate Matter in Air by Tungsten Furnace-Atomic Absorption Spectrometry with a Punching Technique
- A Novel Approach to Deliverable Power in Low-Voltage DC Distribution System on the Basis of Voltage Stability
- Hepatocellular Injuries Observed in Patients with an Eating Disorder Prior to Nutritional Treatment
- Predominant Particles in SF₆-CO₂ Mixture at Temperatures of 300-30,000K (特集 開閉保護技術)
- High-Temperature Properties of CO2 Mixed with N2:—Comparison to CO2 Mixture with O2—
- Effect of N2 and O2 Additions to CO2 on Extinction Limitation of Axial Gas Flow Arc