Formulated representation for upper limitation of deliverable power in low-voltage DC distribution system (特集 電力・エネルギー分野における直流応用技術)
スポンサーリンク
概要
- 論文の詳細を見る
Our previous research have revealed that a deliverable power through a low-voltage DC distribution system has an upper limitation. This limitation results from voltage-instability phenomena occurring for the load of a voltage factor below 1. As the next stage, the present paper proposes two formulas expressing the upper limitation of the deliverable power, Plim, in terms of DC system specifications. These formulated expressions contribute to understand dependence of Plim on DC system specifications and to evaluate Plim without a numerical calculation.
- 2011-04-01
著者
-
Mokhtar Doaa
Nagoya University
-
Yokomizu Yasunobu
Department of Electrical Engineering and Computer Science, Nagoya University
-
Yehia Doaa
Department of Electrical Engineering and Computer Science, Nagoya University
-
Iioka Daisuke
Department of Electrical Engineering and Computer Science, Nagoya University
-
Matsumura Toshiro
Department of Electrical Engineering and Computer Science, Nagoya University
-
Matsumura T
Department Of Electrical Engineering And Computer Science Nagoya University
-
Matsumura Toshiro
Department Of Electrical Engineering And Computer Science Nagoya University
-
Yokomizu Y
Department Of Electrical Engineering And Computer Science Nagoya University
-
Yokomizu Yasunobu
Department Of Electrical Engineering And Computer Science Nagoya University
-
Iioka Daisuke
Department Of Electrical Engineering And Computer Science Nagoya University
関連論文
- Development of Multiple Power Quality Supply System
- Arc parameters around current zero in CO2-blast quenching chamber and their dependences on filled pressure (特集 アークプラズマ・電気接点とその応用)
- Formulated representation for upper limitation of deliverable power in low-voltage DC distribution system (特集 電力・エネルギー分野における直流応用技術)
- Derivation of Receivable Power of Electronic Loads Connected to DC Distribution System on the Basis of Stability Criterion
- Evaluation of Breaking Capability of a Hybrid Fault Current-Limiting Circuit Breaker Based on Mayr-Type Arc Model
- Estimation of Current Interruption for a Circuit Breaker Associated with Inductive Current-Limiter based on Mayr Model
- Effect of a Fault Current Limiter on Interrupting Condition under Breaker Terminal Fault Regime
- Effect of Fault Current Limiter on Transient Recovery Voltage across a Circuit Breaker under Breaker Terminal Fault Condition
- Conductance Diagnostics in Hot Gas Ejected from a Molded Case Circuit Breaker during High Current Arc Interruption
- Formulated representation for upper limitation of deliverable power in low-voltage DC distribution system (特集 電力・エネルギー分野における直流応用技術)
- Correlation between interrupting capability and airflow velocity distribution in flat-type arc quenching chamber
- Total Voltage Drops in Electrode Fall Regions of SF6 Arcs between Electrodes of Cu-W,Cu,Fe,Ti,C and W in Current Range from 10 to 20000A (特集:ガス絶縁およびガス絶縁機器)
- Increase of Inductance Ratio of Flat Type Fault Current Limiter with High-T_c Superconducting Disk
- Required Limiting Impedance and Capacity of Fault Current Limiter Installed in Customer System with Synchronous Generator
- Limiting Impedance of Flat Type Fault Current Limiter with High Tc Superconducting Plate (特集:電力・エネルギー分野を支える静止器技術の新展開)
- Arc Behavior in Rotary-arc Type of Load-break Switch and its Current-interrupting Capability for Different Environmentally Benign Gases and Electrode Materials
- Arc behavior in rotary-arc type of load-break switch and its current-interrupting capability for different environmentally benign gases and electrode materials
- Relationship between Rate of Rise of Recovery Voltage across a Breaker Connected with Fault Current Limiter and Current for Zero-Kilometer Fault Regime
- Thermodynamic Properties at High Temperatures and Particles Present After Arc Extinction in CO_2-CF_3I Mixture
- Particle composition of CO2-CF3I mixture at temperatures of 300-30,000K (特集 IWHV 2007 (5th International Workshop on High Voltage Engineering))
- Thermodynamic, Transport and Radiation Properties of High-temperature CF_3I and Transient Conductance of Residual Arc Sustained in Axial CF_3I Flow
- Influences of Opening Velocity of Electrodes and Arc Column Length on Direct-current Breaking Capability of Arc Device
- Breakdown Voltage of CO2 at Temperatures around 4000K and in Range from 300 to 700K
- Anode-fall Voltages of Air Arcs Between Electrodes of Copper, Silver and Tungsten at Currents up to 1500A
- Thermal Breakdown in High Temperature CO_2 and Air Impressed with DC Voltage at Atmospheric Pressure
- Anode-fall voltages of Air Arcs Between Electrodes of Cu, Ag and W at Currents up to 1500A
- Direct Determination of Lead in Suspended Particulate Matter in Air by Tungsten Furnace-Atomic Absorption Spectrometry with a Punching Technique
- A Novel Approach to Deliverable Power in Low-Voltage DC Distribution System on the Basis of Voltage Stability
- Predominant Particles in SF₆-CO₂ Mixture at Temperatures of 300-30,000K (特集 開閉保護技術)
- High-Temperature Properties of CO2 Mixed with N2:—Comparison to CO2 Mixture with O2—
- Effect of N2 and O2 Additions to CO2 on Extinction Limitation of Axial Gas Flow Arc