G207 中性子ラジオグラフィによるPEFC内水分布の計測とネットワークモデルによるガス流動解析(OS5 水素・燃料電池)
スポンサーリンク
概要
- 論文の詳細を見る
Fuel gas (hydrogen gas) and oxidant gas (air) are supplied to a Polymer Electrolyte Fuel Cell (PEFC). Condensation may occur in the cathode side, since air is super-saturated by the fuel cell reactions. If condensed water exists in a gas diffusion layer (GDL) or the gas channels, it may affect the fuel cell performances because of blocking the oxygen from reaching the cathode reaction site. In order to clarify water effects on performances of a PEFC, visualization and quantitative measurements of water distributions in a PEFC were carried out by means of neutron radiography. A network analysis of gas-velocity distribution was applied for the experimental results. It analyzes the gas-velocity distribution depending on the flow resistance which is the pressure drop. Applying the measured data of water thickness, pressure drop in the gas channel and the GDL can be obtained.
- 一般社団法人日本機械学会の論文
- 2011-06-22
著者
関連論文
- 自励振動型ヒートパイプ内の熱流動現象に関する研究 : 中性子ラジオグラフィによる冷媒挙動の可視化(熱工学,内燃機関,動力など)
- 微小重力下の強制流動沸騰熱伝達に関する軌道上実験の提案
- 807 還水管への蒸気流入によるウォーターハンマー現象に関する研究
- 中性子ラジオグラフィによるエネルギー機器の可視化と診断--中性子イメージ・インテンシファイヤを用いた応用
- F124 ガス給湯器用潜熱回収熱交換器のコンパクト化に関する研究(ボイラ・熱機器)
- 中性子イメージングの流体工学への応用-2
- 中性子イメージングの流体工学への応用-1
- OS4-5 分散蓄熱を利用した集合住宅用熱供給システムに関する研究(OS4 省エネルギー・小型分散電源・コジェネ技術,循環型社会における動力エネルギー技術)
- OS5-3 中性子ラジオグラフィによる固体高分子形燃料電池内結露水の可視化と計測(OS5 水素・燃料電池,循環型社会における動力エネルギー技術)
- Effect of Different Objectives Optimizations on a CHP System's Emissions of CO_2