Motion of thoracoabdominal region due to respiration causes image blur in nuclear imaging modalities such as PET and SPECT. On the other hand, capturing or monitoring such motion provides us useful information. For example, monitoring such motion makes respiration-gated PET and SPECT possible and thus yields less- blurred images. Furthermore, motion of thoracoabdominal region due to respiration may provide us effective information on lung or liver diseases. We have developed a method for estimating lung motion from respiration-gated PET and tried to relate the motion with lung diseases. Recently we have developed a method for reconstructing a four-dimensional magnetic resonance image (4DMRI) of respiratory organ motion from time sequential images of two-dimensional (2D) MR. Those images can also used for dynamic 3D image analysis of thoracoabdominal region. Those techniques are introduced.
- 2009-01-12
著者
-
植 英規
千葉大学フロンティアメディカル工学研究開発センター
-
植 英規
千葉大学工学部情報画像工学科
-
Haneishi Hideaki
Research Center For Frontier Medical Engineering Chiba University:graduate School Of Advanced Integr
-
Haneishi Hideaki
Research Center For Frontier Medical Engineering Chiba University
-
MASUDA Yoshitada
Graduate School of Advanced Integration Science, Chiba University
-
UE Hidenori
Research Center for Frontier Medical Engineering, Chiba University
-
Masuda Yoshitada
Graduate School Of Advanced Integration Science Chiba University
関連論文
- PET/CTで得られた呼吸同期PETにおける吸収補正のための人工的呼吸同期CT像の生成(PET/CT)
- ベアリングの耐久評価法の研究 (第17回品質工学研究発表大会 技術者パワーを発揮させる品質工学)
- 胸部X線CT画像からの肺葉分割
- 呼吸同期PETにおける吸収補正法の提案
- 呼吸ゲートSPECT画像における非線形の動き補正(可視化・レジストレーション)
- MT法を用いた画像評価における単位空間作成法の検討
- 孔版印刷機の画像寸法再現機能の評価方法の研究
- 開発構想段階での機能性評価を活用しての画像形成システムの開発
- Dynamic 3D image analysis of thoracoabdominal region(International Forum on Medical Imaging in Asia 2009 (IFMIA 2009))
- Monitoring and analysis of body surface motion caused by respiration(International Forum on Medical Imaging in Asia 2009 (IFMIA 2009))
- 技術者育成を目的とした「創作実習」での取り組み
- 複数の呼吸位相CT画像からの呼吸性変形量の算出とPETの画質改善への利用(一般)
- Three-dimensional motion acquisition of femur, tibia and patella at knee joint from bi-plane fluoroscopy and CT images(International Forum on Medical Imaging in Asia 2009 (IFMIA 2009))
- A 3D registration method for surgery navigation system of total knee arthroplasty(International Forum on Medical Imaging in Asia 2009 (IFMIA 2009))
- Numerical Simulation of Oscillatory Flow in Realistic Model Human Airways
- Reduction of acquisition time in intersection profile method for 4D-MRI reconstruction of thoracoabdominal organs