418 経年原子力設備の耐震安全評価に関する研究 : 欠陥を有する機器・配管の耐震試験計画(OS3-4 構造健全性,OS3 エネルギー構造機器の健全性評価と信頼性の高度化3)
スポンサーリンク
概要
- 論文の詳細を見る
Since aging degradation of components and piping in NPP (nuclear power plants) has been a key issue related to seismic safety assessments in Japan, JNES (Japan Nuclear Energy Organization) initiated in fiscal year 2004 the three year test program of degraded piping and components. The objectives were: i) to develop a better understanding of seismic strength of degraded BWR components (core shroud and support) and PLR piping (primary loop recirculation piping) with cracks due to aging, ii) to assure the seismic design safety margin of such degraded components and piping, iii) to verify the JSME Code Rules on Fitness-for-Service for NPP. The element tests of core shroud shell, shroud support and PLR piping are to be conducted under quasi static displacement control of monotonous and cyclic loading. The combined model tests are to be performed on the shaking table, using the 1/2.5 scale model of core shroud shell and shroud support, and the 1/3 scale model of PLR piping. All the test models have simulated cracks due to aging degradation, whose cracks are assumed to have the maximum allowable size according to the JSME Code Rules.
- 一般社団法人日本機械学会の論文
- 2005-11-03
著者
-
安部 浩
(独)原子力安全基盤機構(jnes)
-
鈴木 謙一
(独)原子力安全基盤機構(jnes)
-
安部 浩
独立行政法人 原子力安全基盤機構(JNES)
-
鈴木 謙一
独立行政法人 原子力安全基盤機構(JNES)
-
川内 英史
独立行政法人 原子力安全基盤機構
-
川内 英史
独立行政法人原子力安全基盤機構
-
安部 浩
独立行政法人 原子力安全基盤機構
関連論文
- 地震に対する機器耐力 : 電気品試験
- 地震に対する機器耐力 : 横形ポンプ試験
- 大きな地震荷重下での配管系の弾塑性応答と疲労破損についての解析評価(J18-1 解析・設計の高度化・最適化(1),J18 解析・設計の高度化・最適化)
- 3216 配管系終局強度耐震実証試験 : 要素試験
- 418 経年原子力設備の耐震安全評価に関する研究 : 欠陥を有する機器・配管の耐震試験計画(OS3-4 構造健全性,OS3 エネルギー構造機器の健全性評価と信頼性の高度化3)
- 原子力設備耐震試験の経緯と展開 (特集 機械系地震工学の現状)
- 355 経年設備の耐震安全評価に関する研究 : ひび割れを有する配管の耐震試験結果(OS10-4 クリープ,耐震,疲労,OS10 エネルギー機器の経奪変化に関する健金性評価手法の開発とその適用(2))
- 354 経年設備の耐震安全評価に関する研究 : ひび割れを有する炉心シュラウドの耐震試験結果(OS10-4 クリープ,耐震,疲労,OS10 エネルギー機器の経奪変化に関する健金性評価手法の開発とその適用(2))