355 経年設備の耐震安全評価に関する研究 : ひび割れを有する配管の耐震試験結果(OS10-4 クリープ,耐震,疲労,OS10 エネルギー機器の経奪変化に関する健金性評価手法の開発とその適用(2))
スポンサーリンク
概要
- 論文の詳細を見る
Since the age-related degradation of structures and components in NPPs has been a key issue regarding assessments of seismic safety, JNES initiated seismic test programs in fiscal 2004 for the degraded core shroud used in old BWR plants. The objectives were to: i) obtain a better understanding of the vibration characteristics and seismic strength of degraded structures and components having cracks due to aging, ii) ensure a margin of seismic design safety by considering age-related cracking, and iii) verify the JSME Code Rules on Fitness-for-Service for NPPs in Japan. The monotonic and cyclic loading tests of piping element models were conducted. The shaking tests of the about 1/3 scale PLR piping system model were performed on the shaking table. All test models were designed to contain simulated cracking due to aging, involving cracks assumed to have the maximum allowable size according to the JSME Code Rules. This paper reports on the summary of these test results by focusing on vibration characteristics, seismic strength and a seismic design safety margin of the JSME rules.
- 一般社団法人日本機械学会の論文
- 2007-10-24
著者
関連論文
- 地震に対する機器耐力 : 横形ポンプ試験
- 大きな地震荷重下での配管系の弾塑性応答と疲労破損についての解析評価(J18-1 解析・設計の高度化・最適化(1),J18 解析・設計の高度化・最適化)
- 418 経年原子力設備の耐震安全評価に関する研究 : 欠陥を有する機器・配管の耐震試験計画(OS3-4 構造健全性,OS3 エネルギー構造機器の健全性評価と信頼性の高度化3)
- 355 経年設備の耐震安全評価に関する研究 : ひび割れを有する配管の耐震試験結果(OS10-4 クリープ,耐震,疲労,OS10 エネルギー機器の経奪変化に関する健金性評価手法の開発とその適用(2))
- 354 経年設備の耐震安全評価に関する研究 : ひび割れを有する炉心シュラウドの耐震試験結果(OS10-4 クリープ,耐震,疲労,OS10 エネルギー機器の経奪変化に関する健金性評価手法の開発とその適用(2))