In this study, the mechanism of drying shrinkage and water loss of concrete with inferior quality recycled coarse aggregates was discussed from the view point of composite theory. The results are summarized as follows : (1) The drying shrinkage of recycled aggregate concrete increases because of the recycled aggregates with low Young's modulus and large drying shrinkage, and this phenomenon is theoretically explained with a composite model for drying shrinkage. (2) In case of natural aggregate concrete, the most of water loss is from cement paste. On the other hand, in case of recycled aggregate concrete, recycled aggregates also lose water. (3) Although the recycled aggregates lose much water at the early stage of drying, the contribution of the lost water to drying shrinkage is small. After that the water loss from the recycled aggregate pores contributes to drying shrinkage.
- 社団法人日本建築学会の論文
- 2003-11-30
著者
-
成川 匡文
東京電力(株)電力技術研究所
-
江口 清
前田建設工業技術研究所
-
成川 匡文
東京電力(株)建設部 土木・建築技術センター
-
成川 匡文
東京工業大学建築物理研究センター
-
成川 匡文
東京電力(株)
-
江口 清
石川工業高等専門学校建築学科
-
寺西 浩司
名城大学理工学部建築学科
-
成川 国文
東京電力電力技術研究所
-
江口 清
前田建設工業(株)ものづくりセンター
関連論文
- 20301 先端閉塞冶具を用いた鋼管杭の打設による液状化対策工法 : その2 施工について
- 20252 深層混合処理工法を用いた火力発電所建屋基礎地業の検討 : その16 改良地盤の内部応力照査方法の詳細検討とその設計法
- 20251 深層混合処理工法を用いた火力発電所建屋基礎地業の検討 : その15 適用事例とその改良地盤の強度
- 20400 深層混合処理工法を火力発電所建屋基礎地業の検討 : その14 スリット型部分未改良方式の設計法
- 20335 深層混合処理工法を用いた火力発電所建屋基礎地業の検討 : その10 設計法の解析的検討
- 20334 深層混合処理工法を用いた火力発電所建屋基礎地業の検討 : その9 設計法
- 建築構造物の解体に伴い発生するコンクリート塊のリサイクルシステム : 再生粗骨材現場投入方式による再生コンクリートの製造
- 1517 大規模電力建物における再生骨材および再生コンクリートの利用 : その7. 再生コンクリートの製造方法
- 1514 大規模電力建物における再生骨材および再生コンクリートの利用 : その4. 原コンクリートの実態調査
- 建築分野における外部コスト評価の標準化に関する研究 : その3 環境影響評価システムの概要(2002年度大会 (北陸) 学術講演梗概集)