Yb^+ ions were trapped in an uncompensated rf trap with light buffer gas and then the storage time, as well as the total number of the trapped ions, was determined by the rf resonance method. When the ratio of the frequency of the trapping field to that of the macromotion of the trapped ions was an integer, the total number and the storage time were smaller and shorter, respectively, than those obtained when the ratio was a half-integer. A theoretical calculation shows that this effect, called the subharmonic oscillation, is caused by excitation of the macromotion of the trapped ions by the leaked trapping rf field, in the case in which the ion trap has an octupole besides a quadrupole potential.
- 社団法人応用物理学会の論文
- 1992-11-15
著者
-
YODA Jun
National Research Laboratory of Metrology
-
SUGIYAMA Kazuhiko
National Research Laboratory of Metrology
-
Yoda J
National Res. Lab. Metrology Ibaraki Jpn
-
Yoda Jun
National Institute Of Advanced Industrial Science And Technology
関連論文
- Storage and Lifetime Measurements of Multiply Charged Ions Produced by Synchrotron Radiation
- Collisional Quenching Rates by He, N_2 and CH_4 for the 4D_ State in SrII
- Determination of Collisional Quenching Rate for the 4D3/2 State in SrII
- Determination of Collisional Quenching Rate for the 4D_ State in SrII
- A Dye Laser Spectrometer with an External Iodine Cell Designed for Optical Ramsey-Fringe Spectroscopy in a Ca Atomic Beam
- Two-Photon Spectroscopy of the 6S-8S Transitions in Cesium using an Extended-Cavity Diode Laser
- Frequency Stabilization of 421.671nm Second-Harmonic Generation for Studies of ^Sr^+ Ions Confined in an RF Trap
- Resonance of the Macromotion of Ions Trapped in a RF Trap by the Subharmonic Oscillation
- Determination of the Total Number of Ions Confined in an RF Ion Trap
- Measurement of the Storage Time of N_2 Ions Trapped in an RF Ion Trap
- Disappearance of Yb^+ in Excited States from rf Trap by Background Gases
- Spatial Profiles of a Deflected Cesium Atomic Beam
- Determination of Characteristics of Yb^+ Ion Cloud Trapped in a RF Trap with He Buffer Gas
- Construction of an Improved Cesium Frequency Standard (NRLM-II)
- Frequency Stabilization of a Dye Laser to a Reference Cavity with Sub-Hertz Relative Linewidth
- Improvement of the Frequency Stability of the Cs Frequency Standard NRLM-I
- Laser Cooling of Single ^Yb^+ Ions Stored in a RF Trap