Multistage Photoionization Chamber with Different Electrode Distances for the Measurement of the Absolute Intensity in the Vacuum Ultraviolet
スポンサーリンク
概要
- 論文の詳細を見る
A multistage photoionization chamber with different electrode distances has been devised to measure absolute photon fluxes in the vacuum ultraviolet, and was proved useful especially in short wavelengths. The device consists of a four-stage electrode in which the average traveling distance of electrons is increased in steps towards the end of the chamber. By finding the plateaus, the ratio of the ton currents for any two successive stages can be used as a measure of the correct operation of the chamber. Even under the conditions where secondary ionization occurs, the absolute photon flux can be determined by extrapolating the ion current to the distance at which the secondary ionization vanishes. Hence, this method makes possible a direct estimate of the absolute photon flux by a single experimental run regardless of secondary ionization. Examples are given at 584 Å.
- 社団法人応用物理学会の論文
- 1976-01-05
著者
-
Oshio Takanori
Research Institute for Atomic Energy
-
MASUOKA Toshio
Research Institute for Atomic Energy, Osaka City University
-
Masuoka Toshio
Research Institute For Atomic Energy Osaka City University
関連論文
- Electrostatic Compensation Method for a Magnetic Field Effect on an Accelerating Lens of a Heavy Ion Beam Source
- Compact Metal-Ion Beam Source Using Thermal Contact Ionizer
- E2 Heavy Ion Beam Probe for Potential Measurement
- Comparison of Radiometric Standards in the Far Ultraviolet Region : Photodiodes, Ion Chambers, and Thermocouples
- Measurement of Absolute Intensity and Angular Distribution of SOR X-Rays
- Soft X-Ray Absorption Spectra of Metals and Alloys. : I. Be, Al, Sb, Bi and Al-Mg Alloys
- Soft X-Ray Absorption Spectra of Alkali Halides. : I.. KCl and NaCl
- Photographic Observation of the Electron Beam Spot of the INS Synchrotron
- Relation between Photographically Observed Electron Beam Spot of a Synchrotron and the Amplitude of Betatron Oscillation
- Spectral Flux Measurements of Synchrotron Radiation from the INS Machine in the Visible Region
- A 1024-Channel Digital Apparatus for Measurements of the Time Interval Distribution
- Multistage Photoionization Chamber with Different Electrode Distances for the Measurement of the Absolute Intensity in the Vacuum Ultraviolet
- Absolute Photon-Flux and Angular Distribution of the Tokyo Synchrotron Radiation in the Vacuum Ultraviolet
- A Gas Counter with Rare Gas Only
- Photoelectric Yield Spectra of Perovskite Fluorides; KMnF_3 and KZnF_3
- The Etrect of Oxygen on the Photoemission Behavior of p-Terphenyl Single Crystal : PHOTOEMISSION (MAINLY UPS AND XPS)